SmartCell 6A000 User Guide 4-5
Switch Administration
ATM Routing
4.2.2
UNI Routes
Use the
add ATMRoute
command to create UNI routes. For example, connect an end station adapter (with MAC address
00:11:22:33:44:55) to port A2 of the SmartCell 6A000. If the adapter does not support ILMI or its ILMI is
incompatible with the SmartCell 6A000, you must create a static UNI route between the adapter and port A2 of the
SmartCell 6A000.
1.
Enter the
show netprefix
command to obtain the netprefix of port A2
SmartCell ZX # show netprefix
PortNumber(ALL) : a2
Port# NetPrefix
============================================================================
A2 39:00:00:00:00:00:00:00:00:00:14:59:00
SmartCell ZX #
2.
Reconfigure the adapter with an ATM address made from the netprefix of port A2 and the adapter’s
MAC address: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00.
3.
Use the
add ATMRoute
command to create a static UNI route that specifies port A2 and the adapter’s
new ATM address.
SmartCell ZX # add atmroute
PortNumber(A1) : a2
AtmAddress() : 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00
PrefixLength(152) :
Index(0) :
Type(Internal) :
Scope(0) :
MetricsTag(0) :
SmartCell ZX #
4.
Enter the
show ATMRoute
command to check that the UNI route was added.
SmartCell ZX # show atmroute
AddressNumber(ALL) :
No. Port Route Address Type Protocol
================================================================================
1 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80 I MGMT
2 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81 I MGMT
3 -- 39:00:00:00:00:00:00:00:00:00:14:59:00 I PNNI
4 A2 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55 I MGMT
5 -- 39:00:00:00:00:00:00:00:00:00:28:e9:80 I PNNI
6 -- 39:00:00:00:00:00:00:00:00:00:28:f5:00 I PNNI
7 B4 47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT
8 B2 52:00:00:00:00:00:00:00:00:00:14:51:80 I MGMT
SmartCell ZX #SmartCell ZX #
The UNI route appears in the table as route number four (No. 4).
Note
For UNI routes to work with certain devices, ILMI may also need to be disabled
on the SmartCell 6A000. Use the
set PortConfig
command to disable ILMI on
the SmartCell 6A000 on a per-port basis.
Summary of Contents for SmartCell 6A000
Page 12: ...xii SmartCell 6A000 User Guide TABLE OF CONTENTS...
Page 14: ...xiv SmartCell 6A000 User Guide List of Figures...
Page 16: ...xvi SmartCell 6A000 User Guide List of Tables...
Page 18: ...1 2 SmartCell 6A000 User Guide Introduction...
Page 34: ...2 16 SmartCell 6A000 User Guide SmartSwitch ATM Administrator Switch Installation and Setup...
Page 42: ...3 8 SmartCell 6A000 User Guide F amV m h d F 2 6 3 F 1 m 2...
Page 80: ...5 6 SmartCell 6A000 User Guide Troubleshooting Congestion Troubleshooting...
Page 86: ...A 6 SmartCell 6A000 User Guide Technical Specifications Specifications...
Page 94: ...Appendix B 8 SmartCell 6A000 User Guide Managing the SmartCell 6A000 Agent Support...
Page 108: ...Appendix D 12 SmartCell 6A000 User Guide Acronyms...