background image

 

9M426-02 Module Specific Information

6

 

The Blocking state is entered in either of two ways:

¥

Following initialization of the switch.

¥

From the Disabled state when management enables the 
interface.

The Blocking state is exited in any of three ways:

¥

When a protocol timer expires.

¥

When a ConÞguration BPDU is received on this port or another 
port.

¥

Through management action.

Listening

In the Listening state, an interface is preparing to forward trafÞc. 

TrafÞc that is received is discarded.

Station location information is not added to the Filtering Database.

The Listening state is entered from the Blocking state, when the 
Spanning Tree Algorithm and Protocol determines that the 
interface should participate in forwarding trafÞc.

The Listening state is exited in any of three ways:

¥

When a protocol timer expires (the Learning state is then 
entered).

¥

When a BPDU is received on this port or another port (the 
Blocking state is then entered).

¥

Through management action (either the Blocking or the 
Disabled state is then entered).

Learning

In the Learning state, an interface is preparing to forward trafÞc, 
and is learning network addresses to minimize the forwarding of 
unnecessary trafÞc.

TrafÞc that is received is discarded.

Station location information is added to the Filtering Database.

The Learning state is entered from the Listening state when a 
protocol timer expires.

Summary of Contents for MMAC-Plus 9M426-02

Page 1: ...9032253 01 SmartSwitch 9000 9M426 02 Local Management Appendix...

Page 2: ......

Page 3: ...FDDI WAN etc depending on the HSIM installed in the module Modifying Fields and User Privileges To modify elds on this module you must have read write or super user privileges If you have read only pr...

Page 4: ...eral Con guration Screen Table 1 9M426 02 Module Interfaces Interface Number Interface Name Interface Description 1 SMB1 1 Mbps System Management Bus 2 SMB10 10 Mbps System Management Bus 3 HOST 4 INB...

Page 5: ...re 1 9M426 02 LM Screen Hierarchy System Resources HSIM Configuration Screens Flash Download Broadcast Suppression General Configuration SNMP Community Names SNMP Traps Switch Configuration Module Spe...

Page 6: ...BLED 2 disabled ENABLED 3 disabled ENABLED 4 00 00 1D BA DB B0 forwarding ENABLED 5 disabled ENABLED 6 disabled ENABLED 7 disabled ENABLED 8 disabled ENABLED SAVE 9 16 EXIT RETURN The port numbering f...

Page 7: ...t Read Only Lists each switch port on the module MAC Address Read Only Displays the hardware address assigned to each listed port State Read Only Displays the current state of each listed interface Th...

Page 8: ...ed from the Blocking state when the Spanning Tree Algorithm and Protocol determines that the interface should participate in forwarding traf c The Listening state is exited in any of three ways When a...

Page 9: ...te The Forwarding state is exited in either of two ways When a BPDU is received on this port or another port the Blocking state is then entered Through management action either the Blocking or the Dis...

Page 10: ...igure 3 System Resources Screen MMAC Plus Local Management System Resources Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 CPU Type i960 HT 75MHz Flash Memory...

Page 11: ...mount of DRAM installed in the module and how much of it is currently available NVRAM Installed Available Read only Indicates the amount of NVRAM installed in the module and how much of it is currentl...

Page 12: ...fic Information 10 HSIM Configuration Screens For complete information about HSIMs refer to the HSIM User s Guides available in Portable Document Format from the World Wide Web at the following site h...

Page 13: ...le will reboot after the download Figure 4 Flash Download Screen MMAC Plus Local Management Flash Download Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 Down...

Page 14: ...s performed this eld toggles between YES and NO If YES is selected the module reboots after the download is completed The module stores the new rmware image in FLASH memory When the module is reset th...

Page 15: ...highlight EXECUTE at the bottom of the screen and press the Enter key The message TFTP DOWNLOAD WILL COMMIT TO FLASH REBOOT IN PROGRESS displays in the event message line at the top of the screen and...

Page 16: ...of the screen and the new image is downloaded into FLASH memory Using BOOTP to Download Image File To download an image le using BOOTP 1 Use the arrow keys to highlight the Download Method eld 2 Press...

Page 17: ...the forwarding of broadcast packets You can set limits Figure 5 Broadcast Suppression Screen MMAC Plus Local Management Broadcast Suppression Module Name 9M426 02 Firmware Revision 01 00 03 Slot Numb...

Page 18: ...eak Rate Read only The maximum number of broadcast packets received on this port Time Since Peak Read only The time in hours minutes and seconds since the peak occurred Threshold Read only The upper l...

Page 19: ...en the devices Figure 6 SmartTrunk Configuration Screen 03 17 1998 14 58 34 MMAC Plus Local Management SmartTrunk Configuration Screen Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOO...

Page 20: ...WORK connections to participate in SmartTrunking To change a port s connection type press the Space Bar once The desired value appears in the eld SmartTrunk State Read only Displays the current operat...

Page 21: ...bout frames received transmitted ltered and forwarded Figure 7 Switch Statistics Screen MMAC Plus Local Management Switch Statistics Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTP...

Page 22: ...by this port Frames Txmtd Read Only Displays the number of frames transmitted by this port Frames Fltrd Read Only Displays the number of frames ltered by this port Frames Frwded Read Only Displays the...

Page 23: ...e 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 Interface 4 Name INB InOctets 0 Address 00 00 1D BA DB AE InUnicast 0 Last Change 00 days 00 00 00 InNonUnicast 0 Admin S...

Page 24: ...ave been received that were sent to a single address InNonUnicast Read Only Displays the total number of frames that have been received that were delivered to a broadcast or multicast address InDiscar...

Page 25: ...y Displays the length of the frames queue The eld represents the total number of frames that can be contained in queue Address Read Only Displays the MAC address of the interface that is currently bei...

Page 26: ...EAR COUNTERS Command Use this command to reset all statistic counters to zero Viewing Statistics for Another Interface Use the following procedure to view statistics for another interface 1 Highlight...

Reviews: