FDMMIM/LM MESSAGES
A-7
NO HARDWARE FILTER
Cause:
During the power-up diagnostics, the FDMMIM was
unable to find the components that comprise the bridge
filter. The bridge is inoperative. It can receive
configuration and management packets, but it cannot
forward packets.
Action:
Restart the bridge. If restarting does not resolve the
problem, contact Cabletron Systems Technical Support.
NVRAM Management Failure. Restored defaults.
Cause:
The board was left without power for an extended amount
of time with the batter enabled. All default settings were
restored to the module.
Action:
Re-enter the desired settings. If the board remains without
power, be sure to disable the battery.
Permanent DB, illegal port ID specified
Cause:
Remote management requested an action and named a
port that does not exist.
Action:
No action required.
set_port_name ( ) - illegal port id
Cause:
Internal error.
Action:
Contact Cabletron Systems Technical Support.
set_port_name_net ( ) - illegal port id
Cause:
Internal error.
Action:
Contact Cabletron Systems Technical Support.
Received BPDU not a (DEC IEEE) BPDU type
Cause:
The FDMMIM has received a Bridge Protocol Data Unit of
an unknown type. Not all bridges on the network are using
the same Spanning Tree Algorithm protocol.
Action:
Check each bridge in the network. Every bridge must use
the same STA protocol. Mixing protocols causes an
unstable network.