FINISHING THE INSTALLATION
EMC37-12 USER’S GUIDE
3-3
Figure 3-2. Connecting a thin-net segment to the EMC37-12
3. If the Internal Termination Switch is in the OFF position:
a.
Attach a BNC tee-connector to the BNC port on the module.
b. Attach the thin-net segment to one of the female connectors on the
tee-connector.
Note
: You must terminate each segment attached to the tee-connector. If
you do not attach a segment to one of the female connections on the tee-
connector, then a terminator must be placed on that connection.
c.
Attach another thin-net segment or a terminator to the other
female connector of the tee-connector.
3.3
FINISHING THE INSTALLATION
The EMC37-12 is now ready for operation. Before placing the network
into service, test the installation thoroughly, making sure that you can
address all stations and that the EMC37-12 and all stations are indicating
normal operation. Ensure that the networking software is configured
properly to match the installed network. If you encounter errors or
abnormal operation, contact Cabletron Systems Technical Support.
Attach thin-net segment directly to BNC
connector when internal termination
switch is set to on ( ).
When internal termination switch
is set to off ( ):
Connect BNC tee-connector to port.
Attach a terminator or terminated
thin-net segment to one female
connector of tee-connector.
Connect a terminated thin-net
segment to other female connector
of tee-connector.