9F241-12 Module Specific Information
4
6
FNB 1 Pri. (MAC1) Byp.,
FNB 2 Sec. (MAC2) Ins.
The module is attached to the FNB-1 primary
ring and the FNB-2 secondary ring. The
switch that inserts the module into the FNB-1
is turned off. The switch that inserts the
module into the FNB-2 is turned on. MAC-1
resides on the primary of FNB-1; MAC-2
resides on the secondary of FNB-2.
7
FNB 1 Pri. (MAC1) Ins.,
FNB 2 Sec. (MAC2) Byp.
The module is attached to the FNB-1 primary
ring and the FNB-2 secondary ring. The
switch that inserts the module into the FNB-1
is turned on. The switch that inserts the
module into the FNB-2 is turned off. MAC-1
resides on the primary of FNB-1; MAC-2
resides on the secondary of FNB-2.
8
FNB 1 Pri. (MAC1) Ins.,
FNB 2 Sec. (MAC2) Ins.
The module is attached to the FNB-1 primary
ring and the FNB-2 secondary ring. The
switch that inserts the module into the FNB-1
is turned on. The switch that inserts the
module into the FNB-2 is turned on. MAC-1
resides on the primary of FNB-1; MAC-2
resides on the secondary of FNB-2.
9
FNB 1 Sec. (MAC1) Byp.,
FNB 2 Pri. (MAC2) Byp.
The module is attached to the FNB-1
secondary ring and the FNB-2 primary ring.
The switch that inserts the module into the
FNB-1 is turned off. The switch that inserts the
module into the FNB-2 is turned off. MAC-1
resides on the secondary of FNB-1; MAC-2
resides on the primary of FNB-2.
10
FNB 1 Sec. (MAC1) Byp.,
FNB 2 Pri. (MAC2) Ins.
The module is attached to the FNB-1
secondary ring and the FNB-2 primary ring.
The switch that inserts the module into the
FNB-1 is turned off. The switch that inserts the
module into the FNB-2 is turned on. MAC-1
resides on the secondary of FNB-1; MAC-2
resides on the primary of FNB-2.
Table 2. 9F241-12 FNB Resource Configuration Codes (Continued)
Configuration
ID
FDDI Connections
Description