Cabletron Systems 7F06-02 FDDI SmartSwitch User Manual Download Page 2

Summary of Contents for 7F06-02 FDDI SmartSwitch

Page 1: ...Title Page 7F06 02 FDDI SmartSwitch Interface Module User s Guide 903 9031672 02 ...

Page 2: ......

Page 3: ...duct names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equ...

Page 4: ...CI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CABLETRON SYSTEMS INC PROGRAM LICENSE AGREEMENT IMPORTANT Before utilizing this product carefully read this License Agreement This document is an agreement between you the end user and Cabletron Systems Inc Cabletron that sets forth your ri...

Page 5: ...EQUENTIAL DAMAGES IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION SPECIAL INCIDENTAL CONSEQUENTIAL OR RELIANCE DAMAGES OR OTHER LOSS ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBIL...

Page 6: ... 73 23 EEC EN 55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ___________________________________ _____...

Page 7: ...FPIM Module Specifications 2 1 2 1 1 FPIM 00 and FPIM 01 2 1 2 1 2 FPIM 02 and FPIM 04 2 2 2 1 3 FPIM 05 and FPIM 07 2 3 CHAPTER 3 INSTALLATION REMOVAL 3 1 Unpacking The 7F06 02 Module 3 1 3 2 Installing FPIMs 3 2 3 3 Installing Removing The 7F06 02 Module 3 3 3 3 1 Installing in the 7C03 SmartSwitch 3 3 3 3 2 Removing from the 7C03 SmartSwitch 3 4 3 3 3 Installing in the 7C04 or 7C04 R Workgroup ...

Page 8: ...artSwitch Interface Module User s Guide CHAPTER 5 TECHNICAL SPECIFICATIONS 5 1 Standards 5 1 5 2 EMI 5 1 5 3 EMC 5 1 5 4 Network Interfaces 5 1 5 5 Safety 5 2 5 6 Service 5 2 5 7 Physical 5 2 5 7 1 Dimensions 5 2 5 7 2 Weight 5 2 ...

Page 9: ...special features of Cabletron Systems 7F06 02 Module This chapter also includes a list of related manuals Chapter 2 Network Requirements contains a list of available FPIMs and the network requirements that should be considered before installing the 7F06 02 Module Chapter 3 Installation Removal contains instructions for installing and removing the 7F06 02 in the 7C03 MMAC SmartSwitch the 7C04 Workg...

Page 10: ... 7X00 SmartSwitch Module through the chassis backplane The front panel connections are standard Cabletron FPIMs There are two FPIMs for each channel These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors and twisted pair cable either shielded or unshielded Figure 1 1 7F06 02 Module A P S B A SN B F D D I 1 A D D F I 2 B 7F06 02 P S B A SP ...

Page 11: ...dges or routers The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis The 7C04 Workgroup SmartSwitch and the 7C04 R Workgroup SmartSwitch are stand alone chassis that provide the same functions 1 3 FEATURES The 7F06 02 Module provides two FDDI ports via front panel FPIMs The 7F06 02 Module includes the following features 1 3 1 FPIMs The front panel connection...

Page 12: ...anel FPIMs provide FDDI connections allowing the use of single mode or multimode fiber cable with MIC or SC type connectors 1 4 RELATED MANUALS The following Cabletron Systems manuals supplement the procedures and other technical data provided in this manual The procedures will be referenced where appropriate but will not be repeated 7X00 SmartSwitch Control Module User s Guide 7F06 02 Local Manag...

Page 13: ...rebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers Phone 603 332 940...

Page 14: ...Chapter 1 Introduction 1 6 7F06 02 FDDI SmartSwitch Interface Module User s Guide ...

Page 15: ...es Fiber Port Interface Modules FPIM to provide front panel cable connections The FPIMs are user installable Refer to Section 3 2 Installing FPIMs 2 1 1 FPIM 00 and FPIM 01 The FPIM 00 and FPIM 01 provide a multimode fiber connection The FPIM 00 uses a MIC style connector and the FPIM 01 uses an SC type connector The specifications for both devices are listed in Table 2 1 while the transmitter pow...

Page 16: ...onnection The pinouts for both are listed in Table 2 3 The link distance is up to 100 meters on unshielded twisted pair cable as specified by ANSI TP PMD Table 2 2 Transmitter Power Parameters Parameter Typical Value Worst Case Worst Case Budget Typical Budget 50 125 µm fiber 13 0 dBm 15 0 dBm 13 0 dB 17 5 dB 62 5 125 µm fiber 10 0 dBm 12 0 dBm 16 0 dB 20 5 dB 100 140 µm fiber 7 0 dBm 9 0 dBm 19 0...

Page 17: ...cations for both devices are listed in Table 2 4 The link distance is up to 40 kilometers max and 25 kilometers typical on single mode fiber optic cable as specified by ANSI SMF PMD Table 2 4 FPIM 05 and FPIM 07 Specifications Parameter Typical Minimum Maximum Transmitter Peak Wave Length 1300 nm 1270 nm 1330 nm Spectral Width 60 nm 100 nm Rise Time 3 0 nsec 2 7 nsec 5 0 nsec Fall Time 2 5 nsec 2 ...

Page 18: ...Chapter 2 Network Requirements 2 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide ...

Page 19: ...odule by using the following steps 1 Carefully remove the module from the shipping box Save the box and packing materials in the event the module must be reshipped 2 Remove the module from the plastic bag Observe all precautions to prevent damage from Electrostatic Discharge ESD 3 Carefully examine the module and check for damage If damage exists DO NOT install the module contact Cabletron Systems...

Page 20: ...MMAC SmartSwitch chassis by reversing the procedure in Section 3 3 2 Remove the blank front cover over the FPIM slot 3 Install the FPIM as shown in Figure 3 1 Ensure that the rear connector is seated firmly before tightening the two mounting screws Figure 3 1 Installing an FPIM Before installing the 7F06 02 module attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch modul...

Page 21: ... by following the instructions printed on the package 1 As a precaution power down the MMAC 8 before beginning the installation or removal of any modules At the very minimum the 7C03 must be pulled to disconnect it from the power source Damage to modules may result if this procedure is not followed 2 Remove the blank panel covering the slot in which the module will be installed All other slots mus...

Page 22: ... before beginning the installation or removal of any modules At the very minimum the 7C03 must be pulled to disconnect it from the power source Damage to modules may result if this procedure is not followed 2 Use a slotted screwdriver to loosen the two screws that secure the module to the chassis 3 Locate the two ejector tabs on the module to the right of the screws on the top and bottom of the mo...

Page 23: ...martSwitch or SmartSwitch module by following the instructions printed on the package 1 As a precaution power down the MMAC 8 before beginning the installation or removal of any modules At the very minimum the 7C04 or 7C04 R must be pulled to disconnect it from the power source Damage to modules may result if this procedure is not followed 2 Remove the blank panel covering the slot in which the mo...

Page 24: ...e 3 4 Installing the 7F06 02 Module in the 7C04 Workgroup SmartSwitch Figure 3 5 Installing the 7F06 02 Module in the 7C04 R Workgroup SmartSwitch SN 1 2 3 4 7X00 SP Screw Ejector Tab SN 7A06 01 SP FANS 4 3 2 1 PWR SN MAC ADR CPU 7F06 02 7X00 SP SP SP P W R SN M AC AD R C P U 7X00 SP Card Guides ...

Page 25: ...tion power down the MMAC 8 before beginning the installation or removal of any modules At the very minimum the 7C04 or 7C04 R must be pulled to disconnect it from the power source Damage to modules may result if this procedure is not followed 2 Use a slotted screwdriver to loosen the two screws that secure the module to the chassis 3 Locate the two ejector tabs on the module below the screws on th...

Page 26: ...Chapter 3 Installation Removal 3 8 7F06 02 FDDI SmartSwitch Interface Module User s Guide Figure 3 7 Removing the 7F06 02 Module from the 7C04 R Workgroup SmartSwitch FANS SN 4 3 2 1 Ejector Tabs Screws ...

Page 27: ...tatus monitoring system With LANVIEW LEDs the status of each transmit and receive port on the 7F06 02 Module can be determined at a glance This section discusses the function and purpose of the LEDs on the 7F06 02 Module Figure 4 1 shows the LANVIEW LEDs of the 7F06 02 Module Figure 4 1 LANVIEW LEDs A P S B A F D D I 1 7F06 02 SP B A Link Status B Link Status Primary Ring Secondary Ring Receive Tr...

Page 28: ...t Receive LEDs LED Color State Yellow Flashing Data activity flashing to steady on indicates rate Off No activity port can be disabled or enabled Table 4 2 Port Transmit LEDs LED Color State Green Flashing Data activity flashing to steady on indicates rate Off No activity port can be disabled or enabled Table 4 3 Link LEDs A P S B State Green N A N A Green Ports Enabled Active Green Green Off Gree...

Page 29: ...Yellow Green THRU No MAC on Secondary Primary Bypasses Board Green Green Red Yellow WRAP A MAC on Primary Green Yellow Red Yellow WRAP A No MAC on Primary Yellow Green Red Green WRAP B MAC on Primary Yellow Yellow Red Green WRAP B No MAC on Primary Green Green Red Green WRAP AB MAC on Primary Green Off Off Green BYPASS Primary Secondary Green Red Red Green TWISTED A A B B Yellow Off Off Yellow PCM...

Page 30: ...Chapter 4 Troubleshooting 4 4 7F06 02 FDDI SmartSwitch Interface Module User s Guide ...

Page 31: ...e Cabletron Systems reserves the right to change these specifications at any time without notice 5 1 STANDARDS IEEE 802 1D IEEE 802 3i 10BASE T 5 2 EMI The EMI requirements of FCC Part 15 Class A EN 55022 Class A VCCI Class I 5 3 EMC The EMC requirements of EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT 5 4 NETWORK INTERFACES Two FPIMs ...

Page 32: ...ill be a part to ensure that the total system meets allowed limits of conducted and radiated emissions This equipment meets the safety requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 5 6 SERVICE MTBF 200 000 hours MTTR 0 5 hour 5 7 PHYSICAL 5 7 1 Dimensions 31 1D x 22 9 H x 3 1 W centimeters 12 3 D x 9 0 H x 1 2 W inches 5 7 2 Weight Unit 1 8 kgs 4 lbs Shipping 4 5 kgs 10 lbs ...

Reviews: