![Cablematic SimPal-T4 User Manual Download Page 37](http://html1.mh-extra.com/html/cablematic/simpal-t4/simpal-t4_user-manual_3188719037.webp)
SimPal-T4 POWER SOCKET USER MANUAL
3.7.2 Set thermostat control parameters
Method
Master
sends following SMS message in order to:
Set thermostat control parameters:
#24#0#mode#low-temp#high-temp#
(15)
Mode parameter can be 1 or 2, Warming mode is 1, cooling mode is 2;
Temp range should be within -10 to 50 degree.
For example #24#0#1#15#25#, it means set SimPa-T4 thermostat control parameter, work with
warming mode, and turn on socket when temperature lower than 15 degree, turn off socket
37
Summary of Contents for SimPal-T4
Page 1: ...SimPal T4 GSM Power Socket User Manual Manual version 2 0...
Page 14: ...SimPal T4 POWER SOCKET USER MANUAL 1 1 Package contents 14...
Page 15: ...SimPal T4 POWER SOCKET USER MANUAL 1 2 Sockets instructions 15...
Page 16: ...SimPal T4 POWER SOCKET USER MANUAL 16...
Page 17: ...SimPal T4 POWER SOCKET USER MANUAL Figure 2 Temperature sensor Instruction 17...
Page 53: ...SimPal T4 POWER SOCKET USER MANUAL 53...
Page 54: ...l l lt a r D A SimPal _...