BLE RS-485 Serial Adapter

User Manual V1.3

4:2

0x00 : Even Parity

Byte4

Byte5

Byte6

Baud Rate

Device Mode

Reset To Default

00:9600

01:19200

02:38400

03:57600

04:115200

05:230400

06:2400

07:4800

08:1200

09

460800

10

921600

0x00:

 Peripheral

0x01: Reset

6. Command set via COM port:

Command

Value

Description

AT

Check the connection status between control terminal and the RS-232 
adapter. Response: “OK” when the connection is ok. Response: 
“ERROR” when the connection is not ok.

AT

Test the RS-232 status when first connect the adapter with the 
controller.

(Default)

N

The command will disable the auto link function.

?

Inquire the current setting.

BAUD=

This command is used to specify the baud rate of COM port.
The command will need 200 ms delay.

1200

1200 bps

2400

2400 bps

4800

4800 bps

9600

9600 bps

(Default)

19200

19200 bps

38400

38400 bps

57600

57600 bps

115200

115200 bps

230400

230400 bps

460800

460800 bps

921600

921600 bps

?

Inquire the current baud rate.

BIT=

7

7 data bit

8

8 data bit

?

Inquire the current data bit

5

Summary of Contents for BLE-485C

Page 1: ...ge Weight 105 g Package Contents BLE 422 485 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data...

Page 2: ...Remark 1 000000000 by default in red bold character 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 3 Power sup...

Page 3: ...rvice and AT command will support all the functions please check the page 4 section 5 and page 5 section 6 4 3 Range max 50 m in open space 4 4 TX Power Max 3 dBm 4 5 RX Sensitivity 89 dBm typical 4 6...

Page 4: ...UUID UUID_Device Information 0000180A 0000 1000 8000 00805F9B34FB UUID_Firmware Revision String 00002A26 0000 1000 8000 00805F9B34FB UUID_NOTIFY 20 bytes 00031234 0000 1000 8000 00805F9B0130 UUID_RxD...

Page 5: ...connection is ok Response ERROR when the connection is not ok AT Test the RS 232 status when first connect the adapter with the controller Default N The command will disable the auto link function In...

Page 6: ...ice name for the adaptor You can specify a friendly name using 0 to 9 A to Z a to z space and which are all valid characters Note that first space or last space or isn t permitted The default name is...

Page 7: ...re the current setting VERSION This command is used to inquiry the firmware version Inquire the version codes 7 RS 485 Wire connection 8 APP Download Android iOS APP Sample code Please contact the sup...

Page 8: ...n and select one Connect and configure Data transmission test 8 Disconnect TX area RX area Data mode Clear data and log Device list Select one Enable Central Setup Reset Default Serial Port setting Ba...

Reviews: