Cable Detection Utili-Gen User Manual Download Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

   

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

 

 

 

 

Your Utili-Finder 
kit will include 
the following 
items…

BATTERIES

• When battery symbol shows 
   one bar replace batteries. 

• The Utili-Finder 
   locator takes 
   6 x LR6 (AA) 
   batteries.

  

 

STEP 3: SEARCH

• Do not swing the Utili-Finder. Hold at a 90

o

 angle.  

• Sweep the floor in a zig zag pattern ensuring the whole 
   area is covered. 

• When the visual and audible displays are at their highest 
   then you are directly over a buried service.

 

  

FUNCTIONALITY OF KEYS

STEP 4: MARK

• When the bar graph is at the highest point you are 
   directly over the service and should mark the ground. 

• Joining your marks indicates the path of the service. 
 
 

DEPTH READING

MODE SELECT: 

Depress and release the F button  
to select the operating mode.

 

F BUTTON

Functional test: 

Ensure the Utili-Finder and 
Utili-Gen are both turned off. 
Depress and hold the F button 
and turn on the Utilifinder. 
The Utili-Finder will 
automatically carry 
out a functional test.

 

 

Step 1 

Position Utili-Finder over the service

Step 2 

Ensure Utili-Finder is set to 33 kHz mode

Step 3 

Press and release i key for depth reading

+

i

F

i

33 

kHz

metres

33 kHz

Auto

STEP 1: UTILI-GEN

STEP2: UTILI-FINDER

ON

Plug the Utili-Gen 
into the wall and 
switch on the 
power.

  

The green light confirms that power cables can 
be traced. The blue light indicates that some 
other services can be traced. 

220V AC 

i BUTTON 

information:  

Depress the i button for 2 seconds and release. The Utili-Finder website 
address will be displayed, this website provides all online support and 
training information.
 

33kHz 

(default) 

Detects the Utili-Gen signal.

AUTO

 

Detects all services carrying a detectable signal.

PAS means unit is within set tolerances
ERR means unit is outside set tolerances and may need servicing

                 • Repeat the test in a different location if the unit displays ERR
                 • The Locator will automatically repeat the function test if it fails
                 • Repeated failure will indicate a faulty unit, which must be returned for service

• Squeeze trigger 
   to turn on 
   Utili-Finder.
 
• LCD activates. 
 

safety DireCtions 

The symbols used in this manual have the following meanings:

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation or an unintended use which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor or moderate injury and/or 
appreciable material, financial and environmental damage.

Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and 
efficient manner.

The following directions should enable the person responsible for the product, and the person who actually uses the equipment, to anticipate and 
avoid operational hazards.

PermitteD use:

The products are intended to be used for the detection and localization of underground metallic services: cables and metallic pipes. Utili-Gen is for

indoor use only.

rePair:

The products contain no user serviceable parts and do not require regular maintenance. Only Utili-Finder authorised service workshops are entitled to repair

these products.

Do not

• Use products with obviously recognizable damage or defects

• Connect Utili-Gen to a electrical socket with recognizable damage or defects or when wet

• Open or modify the product using tools, for example screwdriver

• Disable electrical equipment safety systems

• Remove hazard notices

HazarDs of use

High mechanical stress, high ambient temperatures or immersion into fluids can cause leakage, fire or explosions of the batteries.

Precautions:

Protect the batteries from mechanical influences and high ambient temperatures. Do not drop or immerse batteries into fluids.

During the transport, shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard.

Precautions:

Before shipping the product or disposing of it, discharge the batteries by running the product until they are flat.

The depth reading might not reflect the real depth when the Utili-Finder picks up the signal induced into the service by the Utili-Gen. This signal is 
radiated from the centre of the service, readings with larger diameter pipes will read shallow. 

Precautions: 

Always compensate depth reading for service size.

The absence of a positive indication does not guarantee the non-existence of a service.
Services without a detectable signal may be present.
The Utilifinder cannot locate non-metallic services such as plastic pipes, typically used by the water and gas utilities.

Precautions: 

Always excavate with care. 

When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are
observed. Before transportation or shipping contact your local passenger or freight transport company.

DisPosal

The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in 
force in your country. 
Always prevent access to the product by unauthorised personnel.

If the product is improperly disposed of, the following can happen:--

• If polymer parts are burnt, poisonous gases are produced which may impair health

• If batteries are damaged or are heated strongly, they can explode and cause poisoning, burning, corrosion or environmental contamination

• By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations, exposing themselves and third parties 

to the risk of severe injury and rendering the environment liable to contamination

• Improper disposal of silicone oil may cause environmental contamination

Precautions:

Product specific treatment and waste management information can be downloaded from the Utili-Finder website at www.utilifinder.com or received

from your Utili-Finder dealer.     

eleCtromagnetiC ComPatibility emC

The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and
electrostatic discharges are present, and without causing electromagnetic disturbances to other equipment.

eleCtromagnetiC raDiation Can Cause DisturbanCes in otHer equiPment. 

Although the product meets the strict regulations and standards which are in force in this respect, the manufacturer cannot completely exclude the 
possibility that other equipment may be disturbed.

labelling:

utili-finDer

utili-gen

DANGER

W

WARNING

C

CAUTION

WARNING

C

CAUTION

WARNING

C

S.No.:

Type:

6x LR6(AA) Alkaline
9V               nominal / 200mA max.

Power:     

NOTICE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

Cable Detection Ltd.
Stoke On Trent
Staffordshire
Made in the UK

WARNING

C

WARNING

C

CAUTION

Reviews: