13
cab - Produkttechnik GmbH
Transfer ribbon :
Type :
Hermes 4N/5N : preferably ribbons designed for the
use with near edge printheads
Hermes 4F/5F : standard ribbons
Length :
1476' in (450 m)
1968' in (600 m) on inquiry
Width :
max. 4.3 in (110 mm)
Core diameter :
1 in (25 mm)
Max. roll diameter :
3.6 in (92 mm)
Colour :
inside or outside
Control panel :
4 Function keys with LED display
Backlit LCD with 2 lines of text, 16 characters per line
LCD can be set to display in 8 different languages
Control features :
Print stop and error message at the LCD display at
- Paper out
- Ribbon out
- Printhead/ Transport system open
Information via peripheral interface and warning light at
- passing the adjusted minimum diameter of the supply roll of
labels or transfer ribbon (if the warning sensors are installed)
Dimensions :
Hermes 4N/4F : Heigth : 15.4 in (390 mm), Width : 10.9 in (277 mm),
Depth :16.5 in (420 mm)
Hermes 5N/5F : Heigth : 21.3 in (542 mm), Width : 10.9 in (277 mm),
Depth : 21.3 in (542 mm)
Weight :
Hermes 4N/4F : 46.3 lb. (21 kg)
Hermes 5N/5F : 55.2 lb. (25 kg)
Operating voltage :
Switcheable between 230 V A.C/ 50 Hz or 115 V A.C/ 60 Hz
Maximum
1,5 A (at 230 V) / 3 A (at 115 V)
power input :
Circuit protection :
T 4 A (at 230 V) / T 6.3 A (at 115 V)
Environment :
Operation at 50° to 95°F (10° to 35°C) at a humidity of 30 to 85%
Transport at -13° to 158°F (-25° to +70°C) at a max. humidity of 95%
non-condensing
Storage at 41° to 104°F (5° to 40°C) at a humidity of 5 bis 85%
Summary of Contents for Hermes Series