10
11
3
Installation
3.3
Preparing the Applicator for Using a Tamp Pad Type 1321
!
Attention!
Make sure that the pad assembly can not fall if the screws are loosen.
Risk of damages and injuries.
It's possible to use the applicator with the cylinder assembly in different high position. That's depend by the type of
pad. In the delivery status the pad assembly is mounted in a low position. That position is suitable for the most pads.
In case of using a large tamp pad it's necessary to change the adapter profile with the, in the shipment of the tamp
included longer profile.
1
2
6
5
3
5
2
3
1
4
1
2
3
Fig. 10
Changing the attachment of the cylinder unit
Fig. 11 Changing adapter profile for tamp pad
116x102 and 116x152
1. Loosen screws (2) and move the pad assembly with the bearing (3) at the adapter profile (1) so that it's possible
to work on the screws (5).
2. Loosen screws (5).
3. For tamp pad 116x102 and 116x152 move the adapter profile (1) out of the tamp assembly (3). Put in the longer
profile (6) in the direction like the picture
4. Move pad assembly with adapter profile (1) in a higher position to the next hole (4).
5. Mount the cylinder assembly in new position with screws (5) .
6. Tighten screws (2).