Setting-up the Applicator
5.1
Adjusting the Supporting Plate
The supporting plate (2) can be set vertically to adjust the position of the label on the tube and therefore to adjust the
measure E.
E
F
B
R
P=37
N
L
E
F
B
R
P=10
N
L
AXON 1.1
AXON 1.2
L
Tube length
F
Length of tread or cap
E
Distance label - upper edge labeling area
R
Distance label - liner edge
P
Distance paper guiding edge - chassis
N
Distance chassis - supporting plate
Supporting plate over chassis - N > 0
Supporting plate under chassis - N < 0
The following correlation can be deduced from the
figure:
L +
N
= F +
E
+ B + R + P
The measure for the positioning of the supporting plate
results in:
N
= (F + B + R + P - L) +
E
Figure 13
Measures for supporting plate positioning
3
2
1
Set the supporting plate (2) by turning the spindle
(1) to the measure
N
.
Figure 14
Setting the supporting plate