CA RIOCN8WS Assembly Instruction Manual Download Page 7

FA00946M4A - 11/2017

FA00946M4A - 11/2017

Functional checks

Issue a start command (each RIO accessory will fl ash * blue) 

Make sure that the RIOLX8WS activates.

Interfere with the gate's opening or closing and check 
whether the RIOPH8WS and/or RIOED8W devices activate 
the required safety function.

When the maneuver is complete, each RIO accessory will 
fl ash* red and switch into LOW POWER mode to preserve 
the batteries.

 

In LOW POWER mode, the photocells will respond 

more slowly - the LED fl ashes blue - to the manual op-
eration test.

* If this does not happen, cut off  the mains power supply 
and increase the radio signal's range/power by setting 
jumper 

 to position H.

Troubleshooting

Alerts

Possible causes

Fix

No RIO accessory is 
saved.

Confi gure RIO 
accessories.

   

The photocells:
a. detect an 

obstruction;

b. are misaligned;
c. have fl at bat-

teries.

a. Remove the 

obstruction.

b. Align the photo-

cells.

c. Replace the 

batteries.

   

The sensitive 
safety-edge does 
not intervene.

Check settings 
and adjustments 
on the sensitive 
safety-edge.

 LED on, steady   LED off    LED fl ashes

 Buzzer active

Reviews: