•
Both transceivers are now in
Joining mode
. They will find each
other and establish encrypted communication. In about 10 seconds,
the TWP LEDs on both transceivers will illuminate (blinking or steady
on), indicating a successful
Join
.
C4L6400-TWP connection diagram
C4L6400-TWP Installation Steps
Step 1. Hardware Check and Preparation
•
Please check the product physical defects. If you find the defects, do not operate the product.
•
Prepare 1) Network cable, 2) Extend UTP cable, 3)
Power supply to C4L6400-TWP units.
(Please check the cable short, Spec. and connection status)
Step 2 . Installation
•
Use one C4L6400-TWP transceiver at each end of the UTP. Up to four remote transceivers and
UTP runs may be connected to a fifth transceiver at the control room using Ethernet splitters.
•
Connect the power supplies into the transceivers to provide power to the entire system, including
the cameras.
•
All transceivers are in Join Mode. They will find each other and establish basic level encrypted
communication.
If you use more than 1 master unit of installation site, you should follow the
Un-joining and joining steps below.
Un-Joining and Joining Transceivers for Encrypted communication(Optional)
If you want to build enhanced encrypted communication Network Group to another, it must be returned
to an un-joined state.
Step 1.Un-Joining to build enhanced encrypted network
•
Do this by applying power, and pressing the small push-button (Grp) for 10 seconds until the TWP
and ETH LEDs illuminate and then go out, about one seconds. The transceiver is now ready to be
joined to build encrypted Network Group.
Step 2. Joining mode
•
For more transceivers in an enhanced encrypted network, disconnect the joined transceiver from
grouped UTP cable and connect the new un-joined transceiver.
•
On the new un-joined transceiver, momentarily depress the small push-button(Grp) using the
straightened paper-clip. The ETH LED will blinking.
•
Depress the small push-button(Grp) on the any transceiver within existing encrypted Network
Group.
Step 3. Adding Transceivers (if required)
•
Disconnect one of the transceivers and replace it with a
new un-joined
transceiver.
•
Repeat step 2 to add additional transceivers to the same Network Group.
C4L6400-TWP Installation Warnings
•
Do not use the transceiver near the harsh (temperature, humidity, cabling quality) installation site.
•
If transceiver flooded by water or other liquid materials, please turn off the power source and
disconnect all of cables from transceiver. And request to C4Line technical team for after service .
•
Do not use transceiver over 120
℉
(50
℃
) temperature condition for transceiver’s operation
performance and lifetime.
•
Do not disassemble transceiver at a person’s service.