Both transceivers are now    in 

Joining mode

. They will find each 

other and establish encrypted communication. In about 10 seconds, 
the TWP LEDs on both transceivers will illuminate (blinking or steady 
on), indicating a successful 

Join

C4L6400-TWP connection diagram 

 

C4L6400-TWP Installation Steps

 

Step 1. Hardware Check and Preparation 

 

Please check the product physical defects. If you find the defects, do not operate the product. 

 

Prepare 1) Network cable, 2) Extend UTP cable, 3)

 

Power supply to C4L6400-TWP units.   

(Please check the cable short, Spec. and connection status) 

Step 2 . Installation 

      Use one C4L6400-TWP transceiver at each end of the UTP.    Up to four remote transceivers and 

UTP runs may be connected to a fifth transceiver at the control room using Ethernet splitters. 

 

Connect the power supplies into the transceivers to provide power to the entire system, including 
the cameras. 

 

All transceivers are in Join Mode. They will find each other and establish basic level encrypted 
communication. 

If you use more than 1 master unit of installation site, you should follow the 
Un-joining and joining steps below. 

Un-Joining and Joining Transceivers for Encrypted communication(Optional) 

If you want to build enhanced encrypted communication Network Group to another, it must be returned 
to an un-joined state. 

Step 1.Un-Joining to build enhanced encrypted network

 

 

Do this by applying power, and pressing the small push-button (Grp) for 10 seconds until the TWP 

and ETH LEDs illuminate and then go out, about one seconds. The transceiver is now ready to be 
joined to build encrypted Network Group. 

Step 2. Joining mode 

 

For more transceivers in an enhanced encrypted network, disconnect the joined transceiver from 
grouped UTP cable and connect the new un-joined transceiver.   

 

On the new un-joined transceiver, momentarily depress the small push-button(Grp) using the 
straightened paper-clip. The ETH LED will blinking. 

 

Depress the small push-button(Grp) on the any transceiver within existing encrypted Network 
Group. 

 

Step 3. Adding Transceivers (if required) 

 

Disconnect one of the transceivers and replace it with a 

new un-joined

 transceiver. 

 

Repeat step 2 to add additional transceivers to the same Network Group. 

C4L6400-TWP Installation Warnings 

 

Do not use the transceiver near the harsh (temperature, humidity, cabling quality) installation site.

 

 

If transceiver flooded by water or other liquid materials, please turn off the power source and 
disconnect all of cables from transceiver. And request to C4Line technical team for after service .

 

 

Do not use transceiver over 120

  (50

) temperature condition for transceiver’s operation 

performance and lifetime.

 

 

Do not disassemble transceiver at a person’s service.

 