C.Scope Cable Avoidance Tool:
Function Checks
Generator Mode
- Locate an outdoor test area that is free from extraneous fields
resulting from overhead and underground cables. The area should also not be near
fences, steel framed buildings, or on reinforced concrete as the signal will be reduced.
Place the Signal Generator on the ground in the normal orientation and switch on - a
tone should be heard. Set to Continuous and ensure highest output power is selected.
With the C.Scope Cable Avoidance Tool in the orientation shown, and Sensitivity rotated
fully clockwise, the results indicated should be obtained.
DISTANCE
MODE
AUDIO
METER
6metres
Generator
Present
Full scale
12metres
Generator
Less than at 6m
Less than Full scale
6metres
Radio
Present
6metres
Power
None
None