CRL JACKSON 1295 RIM PANIC EXIT DEVICE
13
crlaurence.com | usalum.com
NOT TO SCALE
L
FRAME PREPARATION
INTERIOR
EXTERIOR
Mounting Instructions
1. Prepare Lock Stile per Template, drill Cylinder
mounting holes if required.
2. Locate Centerline of Cylinder on exterior of Door
and drill if required.
3. Trim Tail Piece to fit into Panic Drive Bushing Assembly.
4. Mount Cylinder and secure with mounting screws.
(Supplied by lock mfg.) If trim is required prepare
per Template.
5. Locate mounting hole on Inactive Stile.
Drill and tap 1/4"-20 Thds. 40" (1016) from the bottom of
the Door.
FIG. 13
1/4"-20
Tap Hole
(2) 8-32 x 1/4"
FHMS
Base Cover Plate
1/4"-20 x 1/2"
Pan HD SMS
40" (1016) from
bottom of door
40" (1016) from
bottom of door
Apply Dogging
Instruction Label
to back of Cover
Inactive Stile
Jamb
Active Stile
(2) 12-24 x 3/4"
FHSMS
(2) 10-24 x 5/8"
Pan HD MS
Offset Hung Installation
1/8"
(3.2)
1-3/16"
(30.2)
1-5/16"
(61.4)
5/8"
(15.9)
31/32"
(24.6)
2"
(50.8)
3/4"
(19)
2-1/8"
(54)
1-1/16"
(27)
Base Cover Plate
CL
"C" Strike
Cylinder
"C" Strike
DOOR HARDWARE INSTALLATION (CONTINUED)
Panic Attachment
1. Remove front and rear Base Cover Plates by removing
(4) 8-32 x 1/4" Flat HD Screws. Secure active end of
panic by installing (2) 12-24 x 3/4" Flat HD MS.
Secure inactive end with single 1/4"-20 x 1/2" Pan
HD SMS through Base Cover Plate Bracket. Re-install
Base Cover Plates on each end of Panic Base.
2. To install "C" Strike, locate 10-24 tap holes on
Active Stile (2 places).
3. Mount and secure "C" Strike.
4. Check operation of all parts including Cylinder
(if applicable) to assure proper operation.