background image

 

 

 

11.2  Door settings 

Relay output delay time 

 

To set door relay strike time 

 

 

.

*

.  .

Master code

.  .

#

.  .

4

.  .

0 – 99

.  .

#

.  .

*

 

0 – 99 is to set the door relay time to 0 – 99 seconds 

 

 

Door open detection 

 

Door open too long (DOTL) warning. When used with an optional magnetic contact or a magnetic lock with a built-in contact, 
if the door is opened normally, but not closed after one minute, the inside buzzer will beep automatically to remind people to 
close the door and continue for one minute before switching off automatically. 

 

Door forced open warning. When used with an optional magnetic contact or a magnetic lock with a built-in contact, if the 
door is forced open, or if the door is opened after 20 seconds, the inside buzzer and alarm output will both operate. The 
alarm output time is adjustable between 0 – 3 minutes, with the default being 1 minute. 

 

 

To disable door open detection (factory 
default) 

 

 

.

6

.  .

0

.  .

#

.

 

 

To enable door open detection 

 

 

.

6

.  .

1

.  .

#

.

 

 

 

To change a 

PIN

 in card and PIN mode 

(method 1) 

 

Change using card. Note that this is done 
outside of programming mode so the user can 
undertake this themselves. 

 

 

.

*

.  .

Read card

.  .

Old PIN

.  .

#

.  .

New PIN

.  .

#

.  .

New PIN

.  .

#

.

 

 

To change a 

PIN

 in card and PIN mode 

(method 2) 

 

Change using User ID number. Note that this is 
done outside of programming mode so the user 
can undertake this themselves. 

 

 

.

*

.  .

ID number

.  .

#

.  .

Old PIN

.  .

#

.  .

New PIN

.  .

#

.  .

New PIN

. .

#

.

 

 

To delete 

card and PIN

 user 

 

To delete the user just delete the card 

 

 

.

2

.  .

User ID number

.  .

#

.

 

To add a card user in card mode ( 

.

3

.

  

.

0

.

  

.

#

) mode. 

 

To add or delete a 

card

 user 

 

 

The operating is the same as adding and deleting a card user in 

.

3

.

  

.

0

.

  

.

#

 

To delete all users

 

 

To delete all 

users 

 

Please note this is a dangerous operation, use 
with care 

 

 

.

2

.  .

0000

.  .

#

.

 

To unlock the door 

 

For a 

PIN

 user 

 

 

Enter the 

.

PIN

.

 then press 

.

#

.

 

 

For a 

card

 user 

 

 

.

Read card

.

 

 

For a 

card and PIN

 user 

 

 

.

Read card

then enter 

.

PIN

.  .

#

.

 

Summary of Contents for DPS

Page 1: ...c Quantek 59 Sheffield Road Dronfield S18 2GF 44 0 1246 417113 sales cproxltd com www quantek co uk Standalone Keypad Access Control DPS DPS W User Manual Please read the manual carefully before insta...

Page 2: ...delete a PIN or card user 2 User ID number for a PIN user or 2 Read card for a card user Users can be deleted continuously without exiting programming mode To unlock the door for a PIN user Enter the...

Page 3: ...perating voltage 12 24Vdc User capacity 2000 Card reading distance 3 6 cm Active current 60 mA Idle current 25 5 mA Lock output load Max 3A Alarm output load Max 20A Operating temperature 45 to 60 C O...

Page 4: ...alarm positive connected to 12 24V Yellow OPEN Exit button one end the other end connected to GND Brown D_IN Magnetic switch one end the other end connected to GND Red 12 24V 12 24V DC regulated power...

Page 5: ...by Flashing Press keypad Di Operation successful Bright Di Operation failed DiDiDi Enter into programming mode Solid In the programming mode Solid Di Exit from the programming Bright Di Open the door...

Page 6: ...s the last 8 digits printed on the back of the card User ID number auto generation 1 Card number Users can be added continuously without exiting programming mode To add a card user method 4 In this me...

Page 7: ...tes with the default being 1 minute To disable door open detection factory default 6 0 To enable door open detection 6 1 To change a PIN in card and PIN mode method 1 Change using card Note that this...

Page 8: ...re are 10 invalid cards or 10 incorrect PIN s entered in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and inside buzzer will operate for 10 minutes depending on t...

Page 9: ...9 Issue record Site Door location User ID No User name PIN Card number Issue date 0001...