Frequency

Escala

Resolución

Precisión

30~1000Hz

0.1Hz

0.5%+1 graduación

Minimum test voltage: 50V

 

Harmonics test

Orden del armónico

Precisión de la tensión del 

armónico

1

±(3.0%+10)

2-6

±(3.5%+10)

7-8

±(4.5%+10)

9-10

±(5.0%+10)

11-15

±(7%+10)

16-20

±(10%+10)

Minimum test current: 2A; Minimum test voltage: 50V

Accessories

Artículo

Cantidad

Manual de instrucciones abreviado

1

Pilas AA 1.5V

4

Cables de prueba

1

Cables con cocodrilo

3

Cable de comunicación RS232

1

CD con software PC

1

Maletín de transporte

1

32

Replacing the test leads

Replace the test leads if they have arrived damaged or 

peeled.

 

Warning

Use test leads that comply with EN 61010-31, CAT III 

600V or higher.

Replacing the batteries

Warning

To avoid electric shock, be sure to remove the test 

leads from the circuit to be measured before opening 

the battery cover of the clamp.

Warning

Do not mix old and new batteries. Do not mix alkaline, 

normal (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) 

batteries.

1. If the symbol “         ” appears on the display, it means that 

the batteries must be replaced.

2. Loosen the fixing screw of the battery cover and remove it.

3. Replace the exhausted batteries with new ones.

4. Replace the battery cover and fix it in its original position.

Note:

Do not reverse the polarity of the batteries.

Summary of Contents for 8900

Page 1: ...C LOGIC 8900 Digital clamp meter USER MANUAL...

Page 2: ...Test data storage 21 Read saved data 22 RS232C communication interface 22 Input current and voltage 23 Backlitdisplay 23 Auto off 23 Secure clamping diagram 24 Power curve diagram 25 Low battery indic...

Page 3: ...e read this instruction manual carefully Especially the safety contents 01 02 Security instructions This three phase wattmeter is designed and manufactured in accordance with the EN61010 1 safety stan...

Page 4: ...nt waveform 3 A high speed and low consumption single chip microprocessor is used and a sophisticated algorithm is used resulting in great speed and precision in obtaining results and the possibility...

Page 5: ...surement function result and unit symbol 7 Trigger press the trigger and the clamp will open release it and the clamp will close 8 RS232C interface the specialized optical electrical interface cable i...

Page 6: ...you can press the SET key and then the and keys you can adjust the current and voltage scale and then press the SET key again to return to normal mode This key also serves as a confirmation key during...

Page 7: ...scale setting mode you can press the key to change the tension scale During the harmonic check you can change the order of the harmonics When reading the stored data you can press the key to advance...

Page 8: ...se Symbol C A Reverse phase Lack of phase Negative symbol MIN Minimum value MAX Maximum value USED Used MEMO Save READ Read V Voltage W Watts A Current VAr Reactive power Hz Frequency VA Apparent powe...

Page 9: ...perform the measurement and display the result on the screen and the percentage of harmonics present will be shown on the next line 3 In the voltage measurement function press the SET key to display...

Page 10: ...DE key to display the percentage of harmonics and the ratio of harmonic distortion F and r will be displayed cyclically 4 Press the keys to display the value of each individual harmonic If the current...

Page 11: ...he value of power factor voltage and current 3 Press the WATT key to display the phase angle power factor cos and sin A negative power factor means that the measured load is capacitive in nature 4 Pre...

Page 12: ...n 6 Press the WATT key to show the apparent power the power factor cos the phase angle and the sin Negative power factor means that the tested load has capacitive characteristic 7 Press the I key and...

Page 13: ...a data is stored in the memory of the clamp can read it for checking 2 Set the thumbwheel to the SEARCH position and press the HOLD key 3 Press the READ key to display the memory location and the sav...

Page 14: ...iagram Auto off 1 If there is no function change or any key press for 10 minutes the gripper will automatically turn off After the caliper turns off be sure to set the thumbwheel to the OFF position t...

Page 15: ...not connected to any circuit to avoid electric shock Before using the clamp again please make sure the back cover is fully attached Only batteries of the same model or electrical specification can be...

Page 16: ...reading 6000 3 Scale selection Fully automatic scale selection 4 Frequency detection automatic When harmonics are high it is better to use manual adjustment to check the frequency in order to ensure...

Page 17: ...0 1kVAr 600kVAr 3 5 0 1kVAr Minimum test current 2A Minimum test voltage 50V The reactive power is calculated according to the measured values of V A and kW AC RMS voltage Escala Precisi n Resoluci n...

Page 18: ...test leads if they have arrived damaged or peeled Warning Use test leads that comply with EN 61010 31 CAT III 600V or higher Replacing the batteries Warning To avoid electric shock be sure to remove...

Page 19: ...C LOGIC 8900 Pinza amperim trica digital MANUAL DE USUARIO...

Page 20: ...datos de prueba 21 Lectura de datos guardados 22 Interfaz de comunicaci n RS232C 22 Corriente y tensi n de entrada 23 Pantalla retroiluminada 23 Auto apagado 23 Diagrama de sujeci n segura 24 Diagram...

Page 21: ...cialmente los contenidos de seguridad 01 02 Instrucciones de seguridad Esta pinza vatim trica trif sica est dise ada y fabricada de acuerdo a la normativa de seguridad EN61010 1 y a la especificaci n...

Page 22: ...te distorsi n en la forma de onda de corriente 3 Se utiliza un microprocesador de chip sencillo alta velocidad y bajo consumo y se emplea un sofisticado algoritmo dando como resultado una gran rapidez...

Page 23: ...unci n de medici n el resultado y el s mbolo de la unidad 7 Gatillo pulse el gatillo y la pinza se abrir su ltelo y la pinza se cerrar 8 Interfaz RS232C el cable de interfaz ptico el ctrico especializ...

Page 24: ...porcentaje arm nico Tecla SET En el modo de medici n puede presionar la tecla SET y luego las teclas y puede ajustar la escala de corriente y tensi n y luego presionar de nuevo la tecla SET para volv...

Page 25: ...En el modo de ajuste de la escala de tensi n puede presionar la tecla para cambiar la escala de tensi n Durante la comprobaci n de arm nicos puede cambiar el orden de los arm nicos Al leer los datos...

Page 26: ...al S mbolo C A Fase inversa Falta de fase S mbolo negativo MIN Valor m nimo MAX Valor m ximo USED Ocupado MEMO Guardar READ Leer V Tensi n W Vatios A Corriente VAr Potencia reactiva Hz Frecuencia VA P...

Page 27: ...realizar la medici n y mostrar en pantalla el resultado y el porcentaje de arm nicos presentes ser mostrada en la l nea siguiente 3 En la funci n de medici n de tensi n presione la tecla SET para most...

Page 28: ...la LCD 3 Presione la tecla MODE para mostrar el porcentaje de arm nicos y se mostrar n c clicamente la relaci n de distorsi n arm nica F y r 4 Presione las teclas para mostrar el valor de cada arm nic...

Page 29: ...a tensi n y corriente 3 Presione la tecla WATT para mostrar el ngulo de fase factor de potencia cos y sen Un factor de potencia negativo significa que la carga medida tiene car cter capacitivo 4 Presi...

Page 30: ...para mostrar la potencia aparente el factor de potencia cos el ngulo de fase y el sen El factor de potencia negativo significa que la carga comprobada tiene caracter stica capacitiva 7 Presione la tec...

Page 31: ...os a 4 hilos Lectura de datos guardados 1 Cuando un dato est guardado en la memoria de la pinza puede realizar la lectura del mismo para su comprobaci n 2 Sit e la rueda selectora en la posici n SEARC...

Page 32: ...AL INTERFACE PC COM Diagrama de conexi n RS232C 1 Si no se produce un cambio de funci n o una pulsaci n de cualquier tecla durante 10 minutos la pinza autom ticamente se apagar Una vez que la pinza se...

Page 33: ...conectados a ning n circuito para evitar descargas el ctricas antes de usar de nuevo la pinza por favor aseg rese de que la tapa trasera est completamente fijada S lo se pueden utilizar pilas de id n...

Page 34: ...xima 6000 3 Selecci n de escalas Selecci n de escalas totalmente autom tica 4 Detecci n de frecuencia autom tica Cuando los arm nicos son elevados es mejor utilizar el ajuste manual para comprobar la...

Page 35: ...1kVAr 600kVAr 3 5 0 1kVAr M nima corriente de prueba 2A M nima tensi n de prueba 50V La potencia reactiva se calcula de acuerdo a los valores medidos de V A y kW Tensi n AC RMS Escala Precisi n Resolu...

Page 36: ...e prueba si estas han llegado da adas o peladas Advertencia Utilice puntas de prueba que cumplan con las normativa EN 61010 31 CAT III 600V o superior Sustituci n de las pilas Advertencia Para evitar...

Reviews: