C-DOT DSS MAX-XL Installation Manual Download Page 225

 CABLE PREPARATION AND LAYING 

INSTALLATION MANUAL 225 

10.6.10. Detail of BM-CM Clock Cable 

CDOT ASSY NO. 

:  ACB-MAXXBCNN-000 

DRAWING NO. 

:  Fig. 10.46 (a) & 10.46 (b) 

CABLE PART NO. 

:  MCA-CX0188AU-401 

CABLE MARKER NO. 

:  BCNN*  

CABLE SPECIFICATION 

:  RG-188 A/u 50 j  (ohm) coaxial cable 

CABLE UNIT COLOUR CODE 

:-   

CABLE LENGTH 

:  20 mtrs 

SOURCE TERMINATION PART NO. 

:  MCC-BPSCB207-XXX 

MCC-BPPOH207-XXX 

DESTINATION TERMINATION NO. 

:  Same as source termination part No. 

SOURCE 

:  As per Table 10.24 

DESTINATION 

:  As per Table 10.24 

ASSEMBLY PROCEDURE 

:  Refer Fig. 10.46 (b) 

* NN varies from 01 to 64 for BM 1 to BM 32 (for each BM there are two 

cables for Bus0 and Bus1). 

Summary of Contents for DSS MAX-XL

Page 1: ...C DOT DSS MAX XL INSTALLATION MANUAL...

Page 2: ...System Practices Section No 401 305 0496 Draft 03 August 1999 C DOT DSS MAX XL INSTALLATION MANUAL 1999 C DOT Printed in India...

Page 3: ...IATED AS C DOT DSS MAX XL IN THE REST OF THIS PUBLICATION THE INFORMATION IN THIS SYSTEM PRACTICE IS FOR INFORMATION PURPOSES AND IS SUBJECT TO CHANGE WITHOUT NOTICE A COMMENT FORM HAS BEEN INCLUDED A...

Page 4: ...on information than the detailed step by step procedures This manual includes various chapters on floor marking grouting iron work installation cable preparation and laying IOP installation etc Each c...

Page 5: ...ion 19 2 5 Expansion Bolt 20 2 6 Insertion of the Bolt 20 2 7 Tightening of the Bolt 20 Chapter 3 Iron Work Installation 23 3 1 Introduction 23 3 2 Material and Tools Required 23 3 3 Iron Work Fixing...

Page 6: ...pter 8 Power Distribution Panel and its FBI Mounting 85 8 1 Introduction 85 8 2 PDP Installation 85 8 3 Mounting of FBI Card 86 Chapter 9 IOP PDP and OMA Installation 92 9 1 Introduction 92 9 2 Instal...

Page 7: ...s 316 Chapter 13 Invertor Arrangement 317 13 1 Introduction 317 13 2 Inverter Input 317 13 3 Inverter Output Supply Distribution 317 Chapter 14 Sign Writing 320 14 1 Introduction 320 14 2 Sign Writing...

Page 8: ...SUM and ISTU Testing 361 18 12 System Initialisation in Different Configurations 362 18 13 Inter BM Testing 362 18 14 Alarm Testing 363 18 15 System Stability 364 18 16 Load Testing 368 18 17 Exchang...

Page 9: ...iled marking procedure However before carrying out the floor marking certain standard terms need to be understood and are therefore defined 1 2 STANDARD TERMS 1 2 1 Floor Floor means the normal floor...

Page 10: ...uare 1 8 Brass Screws 2mm to 3mm with a cut on top 30 1 4 MARKING PROCEDURE FOR SWITCH ROOM IOP ROOM 1 4 1 Marking of First Datum Line Mark some points along the length of the room at a distance of 60...

Page 11: ...FLOOR MARKING INSTALLATION MANUAL 11...

Page 12: ...string dipped in ultra marine indigo or blue ink Fix some brass screws along the datum lines with a clearance of 2M between them 1 5 MARKING OF SUITE LINES GROUTING HOLES The suite lines are drawn as...

Page 13: ...FLOOR MARKING INSTALLATION MANUAL 13...

Page 14: ...Chapter 1 14 C DOT DSS MAX XL...

Page 15: ...l be added and CM will then be installed in third suite 1 6 MARKING OF IOP ROOM Datum lines are drawn in the IOP room as per the procedure adopted above Refer Fig 1 5 Marking of IOP lines has to be ma...

Page 16: ...Chapter 1 16 C DOT DSS MAX XL...

Page 17: ...FLOOR MARKING INSTALLATION MANUAL 17 DESIGN DSSMAX MAX XL MAX XLIM MXI EL1...

Page 18: ...Chapter 1 18 C DOT DSS MAX XL...

Page 19: ...entre point for drilling An electrical concrete drilling machine with 32 mm carbide tip spiral bit is used for drilling on concrete floor During drilling care is taken for the hole to be straight and...

Page 20: ...he Expansion Bolt is inserted into the hole completely with the expander nut leading in A flat steal plate of 150mm x 150mm x 6mm is used to flatten the steel ferrule prior to loading on the bolt At t...

Page 21: ...GROUTING INSTALLATION MANUAL 21...

Page 22: ...Chapter 2 22 C DOT DSS MAX XL...

Page 23: ...2 MAI WKSTZ001 301 Base Mount Assy 2 1 2 3 4 5 3 MPI WKSTZ006 401 Base Mount Spacer 8 16 32 48 64 80 4 MPI WKSTZ003 401 Base Joining Plate 1 2 4 6 8 10 5 MAP WKSTZ082 201 Vertical Pillar Assy FS 1 1 2...

Page 24: ...x STL M16 8 16 32 48 64 80 30 MCS HESTM032 401 SCR Hex STL M18x60 12 18 36 54 72 90 31 MCW PLSTS005 401 Washer STL M18 25 50 100 150 200 250 32 MCW SPSTS010 401 Washer SPR STL M18 25 50 100 150 200 25...

Page 25: ...assembly after completion of the following activities Floor marking as detailed in Chapter No 1 Grouting as detailed in Chapter No 2 There are two types of basemount assemblies called basemount assemb...

Page 26: ...Chapter 3 26 C DOT DSS MAX XL...

Page 27: ...g plates as shown in detail of B in Fig 3 2 Similarly a gap of 17 mm should be ensured between second and third basemount assy where no joining plate is used This is shown in detail of A in Fig 3 2 3...

Page 28: ...Chapter 3 28 C DOT DSS MAX XL...

Page 29: ...IRON WORK INSTALLATION INSTALLATION MANUAL 29...

Page 30: ...Chapter 3 30 C DOT DSS MAX XL...

Page 31: ...cable runway is to be laid it must be ensured that it does not cause obstructions for laying mother trough assemblies at the beginning and end of the suite There are 3 types of mother trough assembli...

Page 32: ...suite 2 using mother power trough 2 and mother trough 2 L 3 3 4 2 Mounting of Mother Trough Assy Right In an identical way as for mounting mother trough assy L mother trough assy R is mounted and fix...

Page 33: ...rough and false panel assembly 3 trough are fixed on to the child trough Each panel is meant for two cabinets With this the cables dropping from child trough to the cabinets are not visible from the f...

Page 34: ...Chapter 3 34 C DOT DSS MAX XL...

Page 35: ...IRON WORK INSTALLATION INSTALLATION MANUAL 35...

Page 36: ...Chapter 3 36 C DOT DSS MAX XL...

Page 37: ...IRON WORK INSTALLATION INSTALLATION MANUAL 37...

Page 38: ...Chapter 3 38 C DOT DSS MAX XL...

Page 39: ...fter the erection of first suite and cabinet placement second suite erection is to be done as shown in Fig 3 11 It is similar to the first suite The interconnecting trough assemblies are different whi...

Page 40: ...Chapter 3 40 C DOT DSS MAX XL...

Page 41: ...IRON WORK INSTALLATION INSTALLATION MANUAL 41...

Page 42: ...Chapter 3 42 C DOT DSS MAX XL...

Page 43: ...IRON WORK INSTALLATION INSTALLATION MANUAL 43...

Page 44: ...Chapter 3 44 C DOT DSS MAX XL...

Page 45: ...1 Support Box Assembly mm 1 2 MCS HESTM006 401 SCR HEX STL M8x50 6 3 MCW HESSP006 401 Washer M8 6 4 MCW SPSTS006 401 Washer SPR STL M8 6 Table 3 4 5 Mother Trough Assy and Power Trough end Fixing with...

Page 46: ...with Support Box Assembly Sl No CDOT PART NO DESCRIPTION QTY 1 MAI WKSTZ005 201 Child Trough Assembly 1 1 2 MCS HESSM052 401 SCR HEX SST M8x20 12 3 MCW HESSP006 401 Washer SPR STL M8 12 4 MCW SPSTS00...

Page 47: ...ated in power room and DC Distribution Panel DCDP in switch room 4 2 LIST OF MATERIAL AND TOOLS REQUIRED S NO DESCRIPTION QUANTITY 1 Intermediate Distribution Panel 1 2 DC Distribution Panel 2 3 Rawl...

Page 48: ...Chapter 4 48 C DOT DSS MAX XL...

Page 49: ...ber of full suites and IOP PDP inverters emergency light etc Both are mounted on the floor It has two slots on the top one for entry of the input cables from IDP 3 pair in copy 0 and 3 pair in copy 1...

Page 50: ...Chapter 4 50 C DOT DSS MAX XL...

Page 51: ...close to fourth suite as shown in Fig 1 4 switch room layout Internal details of DCDPs are shown in Fig 4 3 4 4 2 Mouting of FBI Cards on DCDP As shown in Fig 4 3 FBI card is mounted on each DCDP with...

Page 52: ...Chapter 4 52 C DOT DSS MAX XL...

Page 53: ...RIAL TOOLS REQUIRED 5 2 1 For Taking Out the Cabinet from Packing Case S NO DESCRIPTION QUANTITY 1 Double End Spanner 17 18 to remove M10 Screw 2 2 Pen Knife 1 5 2 2 For Mounting Castors on Cabinet an...

Page 54: ...ivers for M4 CSK and M8 CH Head Screws 2 4 Ganging Panel MPM AXCBZ098 201 1 5 Ganging Member Right MPM AXCBZ094 401 2 6 Ganging Member Left MPM AXCBZ095 401 2 7 Ganging Bracket 2 MPM AXCBZ097 401 2 8...

Page 55: ...CABINET INSTALLATION INSTALLATION MANUAL 55...

Page 56: ...Chapter 5 56 C DOT DSS MAX XL...

Page 57: ...semount 5 6 LEVELLING MOUNTING THE CABINET ON BASEMOUNT The cabinet is made in level with other cabinet as well as on the Basemount using a levelling rod as shown in Fig 5 6 The levelling screw is mad...

Page 58: ...Chapter 5 58 C DOT DSS MAX XL...

Page 59: ...CABINET INSTALLATION INSTALLATION MANUAL 59...

Page 60: ...Chapter 5 60 C DOT DSS MAX XL...

Page 61: ...CABINET INSTALLATION INSTALLATION MANUAL 61...

Page 62: ...Chapter 5 62 C DOT DSS MAX XL...

Page 63: ...orm of verticals having backmount frames on both sides one for exchange side and the other for line side This MDF is supplied in multiples of 5 verticals The no of verticals to be installed depends up...

Page 64: ...Chapter 6 64 C DOT DSS MAX XL...

Page 65: ...MDF INSTALLATION INSTALLATION MANUAL 65...

Page 66: ...and support assy item 3 using Hex bolt item 26 lock washer item 27 and Hex nut item 28 as shown in Fig 6 5 Cross member assy item 6 passing through long prop assy item 4 is fixed onto Angle long item...

Page 67: ...MDF INSTALLATION INSTALLATION MANUAL 67...

Page 68: ...Chapter 6 68 C DOT DSS MAX XL...

Page 69: ...MDF INSTALLATION INSTALLATION MANUAL 69...

Page 70: ...Chapter 6 70 C DOT DSS MAX XL...

Page 71: ...MDF INSTALLATION INSTALLATION MANUAL 71...

Page 72: ...Chapter 6 72 C DOT DSS MAX XL...

Page 73: ...MDF INSTALLATION INSTALLATION MANUAL 73...

Page 74: ...Chapter 6 74 C DOT DSS MAX XL...

Page 75: ...MDF INSTALLATION INSTALLATION MANUAL 75...

Page 76: ...S Angle 35x35x5x3183 3 11 MPM DFLPA010 401 Strip 5 M S Flat 20x4x1240 22 12 MPM DFMPA011 401 Leg M S Angle 50x50x5x210 6 13 MPM DFMPA012 401 Angle Brace M S Angle 50x34x5 6 14 MPM DFMPA015 201 Horizon...

Page 77: ...p 10 38 MPM DFMPA505 301 Earth Bar 4 2 39 MCS HESTM005 401 SCR HEX STL M8X40 10 40 MPM DFLPA500 301 Test Jack Flat 2 41 MCG EBMIA001 401 Expansion Bolt M6x65 8 42 MCS CSSSZ057 401 SCR CSK SST M5x12 11...

Page 78: ...ed in Operation and Maintenance Control OMC Room at convenient location height of eye level on a table so that the alarm is audible visible to the operator The alarms can be acknowledged by the operat...

Page 79: ...le IOP Printer Cable and IOP HDLC link cables Details on these cables are given in chapter 10 sec 10 5 23 10 6 5 10 6 6 10 6 1 and 10 6 2 respectively 7 3 MM ADP INSTALLATION The ADP is placed on a ta...

Page 80: ...n 10 6 3 For terminations at the ADP end a 25 pin D Type female connector is used and at the HPU end it is two 7 2 IDC connector enclosed in a hood For 48V DC supply a 4 core single cable is connected...

Page 81: ...IOP ADP INSTALLATION INSTALLATION MANUAL 81...

Page 82: ...Chapter 7 82 C DOT DSS MAX XL...

Page 83: ...IOP ADP INSTALLATION INSTALLATION MANUAL 83...

Page 84: ...Chapter 7 84 C DOT DSS MAX XL...

Page 85: ...DP installation and mounting of FBI card on PDP and setting of shorting stubs on it 8 2 PDP INSTALLATION As this forms a part of Iron work no separate unpacking and installation are required 8 2 1 Vis...

Page 86: ...busbars two signal cables are connected to J37 and J39 pins respectively of the FBI card mounted on PDP Similarly FBI card gets the 48V in pins J41 and J43 from copy 0 48V and copy 1 48V busbars resp...

Page 87: ...Copy 0 F16 16 Cabinet No 8 BM LM Copy 1 F17 F18 F19 2 FBI Copy 0 F20 2 FBI Copy 1 Note In case of CM cabinet the Fuse rating i e F5 F6 is 36 Amps For enabling the fuse blow indication some points are...

Page 88: ...se F5 sensing enabled Fuse F6 sensing enabled Filter box fuse sensing enabled for cabinet no 3 TABLE 8 5 SL No W24 W34 W7 W8 STATE 1 Short Short Short Short Fuse F7 sensing enabled Fuse F8 sensing ena...

Page 89: ...s ER46 which is coming from top hat of the cabinet To access we have to remove the top hat All the above cables end in mate n lock connectors thus compatible with earlier MAX L version of connectors u...

Page 90: ...Chapter 8 90 C DOT DSS MAX XL...

Page 91: ...POWER DISTRIBUTION PANEL AND ITS FBI MOUNTING INSTALLATION MANUAL 91...

Page 92: ...and the tag block On the top of the IOP PDP Fuse Blown Indicator FBI card is mounted The function of this card is to sense the presence of 48V supply to IOPs and ADP In case of failure of 48V supply t...

Page 93: ...IOP PDP AND OMA INSTALLATION INSTALLATION MANUAL 93...

Page 94: ...Chapter 9 94 C DOT DSS MAX XL...

Page 95: ...ws 4 3 Wooden Plugs 4 4 Rubber Grommets 4 5 Drilling Machine 1 6 Screw Driver 1 9 3 2 OMA Mounting The OMA panel is wall mountable The front cover of OMA panel is opened with the help of four screws p...

Page 96: ...Chapter 9 96 C DOT DSS MAX XL...

Page 97: ...Point 2 of IOP PDP 6 Gnd IOP PDP FBI Point 1 Switch Room Alarm Power plant Switching cubicle 2 Power Room Alarm 9 3 3 OMA Daisy Chaining Alarm signals of Power failures in switching equipments like va...

Page 98: ...Chapter 9 98 C DOT DSS MAX XL...

Page 99: ...bles iii Signal cables iv MDF cables 10 2 CRIMPING PROCEDURE Most of the cables used are provided with a copper lug at both ends for termination These lugs are crimped to the cable with a proper crimp...

Page 100: ...nt DESTINATION TERMINATION PART NO This number gives the detail of the termination arrangement used at the terminating point SOURCE PLACEMENT This gives the place detail from where the cable will star...

Page 101: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 101...

Page 102: ...Chapter 10 102 C DOT DSS MAX XL...

Page 103: ...FICATION Power cable Single core 240mm2 CABLE UNIT COLOUR CODE Black CABLE LENGTH To suite site requirement SOURCE TERMINATION PART NO MCT ERTCH014 401 300mm2 Terminal Tube DESTINATION TERMINATION NO...

Page 104: ...Chapter 10 104 C DOT DSS MAX XL...

Page 105: ...E UNIT COLOUR CODE Black CABLE LENGTH To suite site requirement SOURCE TERMINATION PART NO MCT ERRIN310 401 25mm2 Ring Terminal Crimp Type DESTINATION TERMINATION NO MCT ERRIN310 401 25mm2 Ring Termin...

Page 106: ...Chapter 10 106 C DOT DSS MAX XL...

Page 107: ...le 48V Gnd Bus Bar 240mm2 GR01 5 ACB MAXLGM01 000 FIG 10 3 Earth Collector Plate MDF Lines 25mm2 GMO1 6 ACB MAXLGM02 000 FIG 10 3 Earth Collector Plate MDF Trunks 25mm2 GMO2 7 ACB MAXLGMP1 000 FIG 10...

Page 108: ...ERRIN200 401 SOURCE Earth collector plate DESTINATION Antistatic flooring ASSEMBLY PROCEDURE Crimping tool SYB 95 Die to be used JBR 1 Note 1 For earthing the antistatic material a copper strip is fa...

Page 109: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 109...

Page 110: ...N Power cable Single core 25mm2 CABLE UNIT COLOUR CODE Black CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERRIN310 401 25mm2 Ring Terminal crimp type DESTINATION TERMINATION NO Stripped...

Page 111: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 111...

Page 112: ...CATION Power cable Single core 25mm2 CABLE UNIT COLOUR CODE Black CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERRIN310 401 25mm2 Ring Terminal Crimp type DESTINATION TERMINATION NO MCT...

Page 113: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 113...

Page 114: ...DCDP2 Digital GND Bus Bar PDP Digital GND Bus Bar Suite 5 25mm2 GDP5 7 ACB MAXLGCP1 000 Fig 10 6 DCDP1 Chassis GND Bus Bar PDP Chassis GND Bus Bar Suite 1 25mm2 GCP1 8 ACB MAXLGCP2 000 Fig 10 6 DCDP1...

Page 115: ...Single core 240mm2 CABLE UNIT COLOUR CODE Blue Red CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERTCH014 401 300mm2 Cu Tube Terminal Crimp Type DESTINATION TERMINATION NO MCT ERTCH014 40...

Page 116: ...Chapter 10 116 C DOT DSS MAX XL...

Page 117: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 117...

Page 118: ...Chapter 10 118 C DOT DSS MAX XL...

Page 119: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 119...

Page 120: ...Chapter 10 120 C DOT DSS MAX XL...

Page 121: ...DE As per Table 10 3 CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERTCH014 401 300mm2 Terminal Tube DESTINATION TERMINATION NO MCT ERTCH014 401 300mm2 Terminal Tube SOURCE As per Table 1...

Page 122: ...Chapter 10 122 C DOT DSS MAX XL...

Page 123: ...000 Fig 10 9 IDP 48V busbar DCDP2 48V busbar 240mm2 PPD2 Blue 3 ACB MAXLPGD1 000 Fig 10 9 IDP 48V GND busbar DCDP1 48V GND busbar 240mm2 PGD1 Red 4 ACB MAXLPGD2 000 Fig 10 9 IDP 48V GND busbar DCDP2...

Page 124: ...LE SPECIFICATION Power cable Single core 25mm2 CABLE UNIT COLOUR CODE As per Table 10 4 CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERRIN310 401 25mm2 Ring Terminal Crimp Type DESTINATI...

Page 125: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 125...

Page 126: ...IOP PDP 25mm2 PPM1 Blue 2 ACB MAXLPPM1 000 Fig 10 10 48V DCDP1 IOP PDP MCB 48V busbar IOP PDP 25mm2 PPM1 do 3 ACB MAXLPPC1 000 Fig 10 10 48V DCDP1 MISC MCB IOP PDP 48V OMC busbar 25mm2 PPC1 do 4 ACB M...

Page 127: ...SPECIFICATION Power cable Single core 120mm2 CABLE UNIT COLOUR CODE As per Table 10 5 CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERRIN421 401 150mm2 Ring Terminal Crimp Type DESTINATI...

Page 128: ...Chapter 10 128 C DOT DSS MAX XL...

Page 129: ...10 11 DCDP2 48V MCB Suite 4 PDP copy 0 48V busbar Suite 4 120mm2 PL07 Blue 8 ACB MAXLPL08 000 FIG 10 11 DCDP2 48V MCB Suite 4 PDP copy 1 48V busbar Suite 4 120mm2 PL08 Blue 9 ACB MAXLPL09 000 FIG 10 1...

Page 130: ...bar PDP copy 1 48V gnd busbar Suite 4 120mm2 PN08 Red 19 ACB MAXLPN09 000 FIG 10 11 DCDP2 48V gnd busbar PDP copy 0 48V gnd busbar Suite 5 120mm2 PN09 Red 20 ACB MAXLPN10 000 FIG 10 11 DCDP2 48V gnd b...

Page 131: ...PECIFICATION Power cable Single core 25mm2 CABLE UNIT COLOUR CODE As per Table 10 6 CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCT ERRIN310 401 25mm2 Ring Terminal Crimp Type DESTINATION T...

Page 132: ...Chapter 10 132 C DOT DSS MAX XL...

Page 133: ...DP1 48V gnd Invertor 1 48V gnd cable 25mm2 PGI1 Red 3 ACB MAXLPPI2 000 FIG 10 12 DCDP1 48V INV 2 Invertor 2 48V cable 25mm2 PPI2 Blue 4 ACB MAXLPGI2 000 FIG 10 12 DCDP1 48V gnd Invertor 2 48V gnd cabl...

Page 134: ...core 16mm2 CABLE UNIT COLOUR CODE Red CABLE LENGTH As per Table 10 7 SOURCE TERMINATION PART NO MCT ERRIN038 401 16mm2 Ring Terminal Crimp Type DESTINATION TERMINATION NO MCT ERRIN038 401 16mm2 Ring T...

Page 135: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 135...

Page 136: ...DP GND Cabinet 7 copy 0 Red busbar 16mm2 PG13 7710 8 ACB MAXLPG15 000 FIG 10 13 PDP GND Cabinet 8 copy 0 Red busbar 16mm2 PG15 8680 9 ACB MAXLPG02 000 FIG 10 13 PDP GND Cabinet 1 copy 1 Red busbar 16m...

Page 137: ...m2 FPXX CABLE UNIT COLOUR CODE Blue CABLE LENGTH As per Table 10 8 a PPXX 120 cm FPXX SOURCE TERMINATION PART NO 16mm2 Reducer Terminal DESTINATION TERMINATION NO MCT ERRIN038 401 16mm2 Ring Terminal...

Page 138: ...Chapter 10 138 C DOT DSS MAX XL...

Page 139: ...0 Blue Busbar FBI Card J13 16mm2 1mm2 PP13 FP13 8075 1200 8 ACB MAXLPP15 000 FIG 10 14 a PDP fuse F15 Cabinet 8 copy 0 Blue Busbar FBI Card J15 16mm2 1mm2 PP15 FP15 9055 1200 9 ACB MAXLPP02 000 FIG 10...

Page 140: ...7 000 FIG 10 14 b Copy 0 busbar of CM cabinet FBI card J17 2 5mm2 FP17 3700 18 ACB MAXXFP19 000 FIG 10 14 b Copy 0 busbar of CM cabinet FBI card J19 2 5mm2 FP19 3700 19 ACB MAXXFP18 000 FIG 10 14 b Co...

Page 141: ...401 CABLE MARKER NO FPXX CABLE SPECIFICATION Power Cable 2 5mm2 CABLE LENGTH As per Table 10 8 a Sl No 17 20 SOURCE TERMINATION PART MCT ERRIN102 401 Ring terminal DESTINATION TERMINATION NO MCC FASTP...

Page 142: ...Chapter 10 142 C DOT DSS MAX XL...

Page 143: ...DFXX CABLE SPECIFICATION Power Cable single core 1mm2 CABLE UNIT COLOUR CODE Blue CABLE LENGTH As per Table 10 8 b SOURCE TERMINATION PART MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 Insulati...

Page 144: ...Chapter 10 144 C DOT DSS MAX XL...

Page 145: ...E Black CABLE LENGTH 7 Meters SOURCE TERMINATION PART MCC SPFSC702 002 MCC PIFSC000 001 CONN S R FEMALE 2 PIN HOUSING DESTINATION TERMINATION PART MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 I...

Page 146: ...Chapter 10 146 C DOT DSS MAX XL...

Page 147: ...16 2800mm 7 ACB MAXLDF17 000 Invertor 1 MCB FBI card J7 DF17 1800mm 8 ACB MAXLDF18 000 Invertor 2 MCB FBI card J8 DF18 1800mm 9 ACB MAXLDF19 000 IOP PDP copy 0 MCB FBI card J9 DF19 1800mm 10 ACB MAXLD...

Page 148: ...ble Single Core 10mm2 CABLE UNIT COLOUR CODE Black CABLE LENGTH As per Table 10 9 SOURCE TERMINATION PART NO 10mm2 Ring Terminal MCT ERRIN200 401 DESTINATION TERMINATION NO 10mm2 Ring Terminal MCT ERR...

Page 149: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 149...

Page 150: ...PDP Digital earth Cabinet 4 copy 0 Black Busbar 10mm2 PD04 5780 5 ACB MAXLPD05 00 FIG 10 15 PDP Digital earth Cabinet 5 copy 0 Black Busbar 10mm2 PD05 6940 6 ACB MAXLPD06 00 FIG 10 15 PDP Digital eart...

Page 151: ...N Power Cable Single Core 10mm2 CABLE UNIT COLOUR CODE Black CABLE LENGTH As per Table 10 10 SOURCE TERMINATION PART NO 10mm2 Ring Terminal MCT ERRIN200 401 DESTINATION TERMINATION NO 10mm2 Ring Termi...

Page 152: ...Chapter 10 152 C DOT DSS MAX XL...

Page 153: ...ACB MAXLPE02 000 do Cabinet 2 Chassis 3940 PE 02 3 ACB MAXLPE03 000 do Cabinet 3 Chassis 4940 PE 03 4 ACB MAXLPE04 000 do Cabinet 4 Chassis 5940 PE 04 5 ACB MAXLPE05 000 do Cabinet 5 Chassis 7100 PE...

Page 154: ...FICATION PVC insulated 2 5mm2 cable CABLE UNIT COLOUR CODE Black CABLE LENGTH As per Table 10 11 SOURCE TERMINATION PART MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 Insulating Boot DESTINATION...

Page 155: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 155...

Page 156: ...binet 6 Copy 0 FF06 7070 7 ACB MAXLFF07 000 FBI Card J27 Cabinet 7 Copy 0 FF07 8080 8 ACB MAXLFF08 000 FBI Card J28 Cabinet 8 Copy 0 FF08 9050 9 ACB MAXLFF09 000 FBI Card J29 CM cabinet Copy 0 child c...

Page 157: ...XCT02 000 Powermate Male Connector MCC MPMSC000 001 Pin for Male Connector DESTINATION TERMINATION NO MCC PPFXCT02 000 Powermate Female Connector MCC MPSSC000 001 Pin for Female Connector SOURCE BM LM...

Page 158: ...Chapter 10 158 C DOT DSS MAX XL...

Page 159: ...OURCE TERMINATION PART NO MCC PPMXCT02 000 Power Mate Male Connector MCC MPMSC000 001 Pin for Male Connector DESTINATION TERMINATION NO MCT ERRIN017 401 Ring Terminal 2 5mm2 SOURCE Frame 1 copy 1 Filt...

Page 160: ...Chapter 10 160 C DOT DSS MAX XL...

Page 161: ...10mm2 Reducer Terminal DESTINATION TERMINATION NO MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 Insulating Boot SOURCE Refer Table 10 12 a DESTINATION Refer Table 10 12 a ASSEMBLY PROCEDURE Cri...

Page 162: ...Chapter 10 162 C DOT DSS MAX XL...

Page 163: ...Red CABLE LENGTH 1200mm SOURCE TERMINATION PART NO MCT ERRIN102 401 2 5mm2 Ring Terminal Crimp Type DESTINATION TERMINATION NO MCC FASTP001 401 MCC FASTP002 401 SOURCE Refer Table 10 12 b DESTINATION...

Page 164: ...Chapter 10 164 C DOT DSS MAX XL...

Page 165: ...R NO DPUX Blue DGUX Red CABLE SPECIFICATION PVC insulated 2 5mm2 cable CABLE UNIT COLOUR CODE As per Table 10 13 CABLE LENGTH As per Table 10 13 SOURCE TERMINATION PART NO MCT ERRIN102 401 2 5mm2 Ring...

Page 166: ...Chapter 10 166 C DOT DSS MAX XL...

Page 167: ...3 DPU2 Blue 2800mm 3 ACB MAXLDPU3 000 DCDP2 Blue busbar copy 0 FBI card J41 DPU3 Blue 1800mm 4 ACB MAXLDPU4 000 DCDP2 Blue busbar copy 1 FBI card J43 DPU4 Blue 2800mm 5 ACB MAXLDGU1 000 DCDP1 Red busb...

Page 168: ...opy 1 CABLE SPECIFICATION 2 5mm2 PVC insulated Cable CABLE UNIT COLOUR CODE Blue CABLE LENGTH 75 cm SOURCE TERMINATION PART NO MCT ERRIN102 401 Ring Terminal 2 5mm2 Crimp type DESTINATION TERMINATION...

Page 169: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 169...

Page 170: ...ND copy 1 CABLE SPECIFICATION 2 52 PVC insulated Cable CABLE UNIT COLOUR CODE Red CABLE LENGTH 85 cm SOURCE TERMINATION PART NO MCC ERRIN102 401 Ring terminal 2 5 mm2 crimp type DESTINATION TERMINATIO...

Page 171: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 171...

Page 172: ...insulated 2 5mm2 cable CABLE UNIT COLOUR CODE Red CABLE LENGTH Site dependent SOURCE TERMINATION PART MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 Insulating Boot DESTINATION TERMINATION NO MCC...

Page 173: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 173...

Page 174: ...F3 000 Suite 1 PDP FBI card J32 DCDP2 FBI card J42 PGF3 4 ACB MAXLPGF4 000 Suite 2 PDP FBI card J32 Suite 1 PDP FBI card J42 PGF4 5 ACB MAXLPGF5 000 Suite 3 PDP FBI card J32 Suite 2 PDP FBI card J42 P...

Page 175: ...ION PART NO MCC FASTP001 401 Faston Receptacle MCC FASTP002 401 Insulating Boot DESTINATION TERMINATION NO Stripped wire SOURCE As per Table 10 15 a DESTINATION As per Table 10 15 a ASSEMBLY PROCEDURE...

Page 176: ...Chapter 10 176 C DOT DSS MAX XL...

Page 177: ...oot DESTINATION TERMINATION NO Stripped wire SOURCE As per Table 10 15 b DESTINATION As per Table 10 15 b ASSEMBLY PROCEDURE Crimping Tool SYT 2 Note 1 XXX takes values as per Table 10 15 b TABLE 10 1...

Page 178: ...PMG1 Red CABLE SPECIFICATION PVC insulated 2 5mm2 CABLE UNIT COLOUR CODE Blue Red CABLE LENGTH Site dependent SOURCE TERMINATION PART NO 2 5mm2 Ring Terminal MCT ERRIN018 401 DESTINATION TERMINATION N...

Page 179: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 179...

Page 180: ...PVCSCP03 401 CABLE MARKER NO PGR1 CABLE SPECIFICATION PVC insulated 2 5mm2 cable CABLE UNIT COLOUR CODE Red CABLE LENGTH Site dependent SOURCE TERMINATION PART NO Stripped wire DESTINATION TERMINATION...

Page 181: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 181...

Page 182: ...pendent SOURCE TERMINATION PART NO 2 5mm2 Ring Terminal MCT ERRIN018 401 DESTINATION TERMINATION NO Stripped wire SOURCE As per Table 10 16 DESTINATION OMA Panel PT 1 INV TB 1 Table 10 16 ASSEMBLY PRO...

Page 183: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 183...

Page 184: ...O MCA PVCSCP03 401 CABLE MARKER NO GP01 CABLE SPECIFICATION PVC Insulated 2 5mm2 CABLE UNIT COLOUR CODE Red CABLE LENGTH Site dependent SOURCE TERMINATION PART NO 2 5 mm2 Ring Terminal MCT ERRIN018 40...

Page 185: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 185...

Page 186: ...nd 80 0 2mm cable CABLE LENGTH 6 mtrs SOURCE TERMINATION PART NO MCC PSICZ000 301 4 Pin Power Plug female DESTINATION TERMINATION NO MCC PSICZ000 301 4 Pin Power Plug Female SOURCE Refer Table 10 17 D...

Page 187: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 187...

Page 188: ...e multistrand 32 0 2 mm PVC wire CABLE LENGTH 35 mtrs max SOURCE TERMINATION Power supply shell connector MCC PDFXST02 000 DESTINATION TERMINATION NO Power Supply Shell Connector MCC PDFXST02 000 SOUR...

Page 189: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 189...

Page 190: ...2 IOP0 to IOP1 3 Central Module to ADP 4 BP Terminal Cables AM CM BM and SUM 5 IOP to VDU terminals 6 IOP to printers 7 Test access cables 8 Concentration cables 9 BM CM Data cable 10 BM CM Clock cab...

Page 191: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 191...

Page 192: ...yethylene high density cable WIRE SPECIFICATIONS 0 4 mm conductor wire dia including insulation 1 mm SOURCE TERMINATION PART NO MCC BPCSZ011 401 MCC BPCSZ012 401 and MCC BPCSZ022 401 SOURCE PLACEMENT...

Page 193: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 193...

Page 194: ...X0 000 IOP 0 VHI HDLC2 CM HPU frame 6 copy 0 J20 position 3 HDX0 2 ACB IOPHHDX1 000 IOP 0 VHI HDLC0 CM HPU frame 6 copy 1 J36 position 3 HDX1 3 ACB IOPHHDY0 000 IOP 1 VHI HDLC2 CM HPU frame 6 copy 0 J...

Page 195: ...twisted pair cable 26 AWG CABLE UNIT COLOUR CODE Grey CABLE LENGTH 5 5 mtrs max SOURCE TERMINATION PART NO 1 25 pin D type wire wrap male MCC DCMMZ002 301 2 Hood with screw lock MCC DHXXXT25 100 DESTI...

Page 196: ...Chapter 10 196 C DOT DSS MAX XL...

Page 197: ...air single strand round cable unit WIRE SPECIFICATIONS 0 4 mm conductor wire dia including insulation 1 mm SOURCE TERMINATION PART NO MCC BPCSZ011 401 MCC BPCSZ012 401 MCC BPCSZ022 401 SOURCE PLACEMEN...

Page 198: ...Chapter 10 198 C DOT DSS MAX XL...

Page 199: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 199...

Page 200: ...Chapter 10 200 C DOT DSS MAX XL...

Page 201: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 201...

Page 202: ...cluding unsheathed section SOURCE TERMINATION PART NO 7X2 IDC Crimp connector MCC BPCSZ012 401 MCC BPCSZ011 401 MCC BPCSZ022 401 DESTINATION TERMINATION PART NO 25 pin D type wire wrap Female MCC DCFM...

Page 203: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 203...

Page 204: ...hone cable only 4 pairs are used CABLE LENGTH 25m max excluding unsheathed section SOURCE TERMINATION PART NO 7X2 IDC Crimp connector MCC BPCSZ012 401 MCC BPCSZ011 401 source MCC BPCSZ022 401 DESTINAT...

Page 205: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 205...

Page 206: ...PART NO 9 Pin D type wire wrap MCC DCFMZ009 301 MCC DHXXXT09 100 DESTINATION TERMINATION PART NO 25 Pin D type wire wrap MCC DCFMZ002 301 MCC DHXXXT25 100 SOURCE As per Table 10 19 DESTINATION As per...

Page 207: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 207 DESIGN DSSMAX MAX XL MAX XLIM MXI IPTC...

Page 208: ...ASIO 5 CRP Terminal TEX5 6 ACB IOPHTEX6 000 IOP0 VHI ASIO 6 Operator Terminal TEX6 7 ACB IOPHTEX7 000 IOP0 VHI ASIO 7 Operator Terminal TEX7 8 ACB IOPHTEY1 000 IOP1 VHI console Console Terminal TEY1...

Page 209: ...SOURCE TERMINATION PART NO 9 pin D type wire wrap female MCC DCFMZ009 301 MCC DHXXXT09 100 DESTINATION TERMINATION PART NO 25 pin D type wire wrap female MCC DCFMZ002 301 MCC DHXXXT25 100 SOURCE As pe...

Page 210: ...Chapter 10 210 C DOT DSS MAX XL DESIGN DSSMAX MAX XL MAX XLIM MXI IPPC...

Page 211: ...r table 10 21 SOURCE TERMINATION PART NO MCC BPCSZ009 401 and 2X7 contact block flat cable MCC BPCSZ010 401 2X7 piercing block with cover DESTINATION TERMINATION PART NO MCC BPCSZ009 401 and MCC BPCSZ...

Page 212: ...Chapter 10 212 C DOT DSS MAX XL...

Page 213: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 213...

Page 214: ...00 TA05 X 1 4 2 A 3 X 3 4 2 A 4 X 3 5 2 A 4 X 3 4 2 A 4 X 3 5 2 A 4 X 3 6 2 A 4 Daisy chained Cable for test access 280 cm Note Connector insertion position indicated as X P Q R S T X BM number P Rack...

Page 215: ...09 401 and MCC BPCSZ010 401 DESTINATION TERMINATION PART NO MCC BPCSZ009 401 and MCC BPCSZ010 401 SOURCE As per Table 10 22 DESTINATION As per Table 10 22 CONNECTIVITY CONDUCTOR ALIGNMENT One to one B...

Page 216: ...Chapter 10 216 C DOT DSS MAX XL...

Page 217: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 217...

Page 218: ...A 1 Terminal Unit 14 ACB MAXXTL14 000 TL14 X 1 2 14 A 3 X 3 1 14 A 1 TU21 TU22 15 ACB MAXXTL15 000 TL15 X 1 2 13 A 4 X 3 1 13 A 2 16 ACB MAXXTL16 000 TL16 X 1 2 14 A 4 X 3 1 14 A 2 17 ACB MAXXTL17 000...

Page 219: ...0 ACB MAXXTL40 000 TL40 X 1 4 14 A 4 X 3 4 14 A 2 41 ACB MAXXTL41 000 TL41 X 3 4 13 A 3 X 3 5 13 A 1 Terminal Unit 42 ACB MAXXTL42 000 TL42 X 3 4 14 A 3 X 3 5 14 A 1 TU42 TU43 43 ACB MAXXTL43 000 TL43...

Page 220: ...r 126 sq mm PEHD insulated twisted into pair CABLE UNIT COLOUR CODE CABLE LENGTH 2 x 20 meter SOURCE TERMINATION PART NO MCC BPCCB307 302 MCC BPWPB307 302 MCC BPCSZ013 401 DESTINATION TERMINATION PART...

Page 221: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 221...

Page 222: ...Chapter 10 222 C DOT DSS MAX XL...

Page 223: ...D11 7 B 1 2 6 7 BD13 8 A 3 4 7 8 BD15 8 B 1 2 8 9 BD17 9 A 3 4 9 10 BD19 9 B 1 2 10 11 BD21 10 A 3 4 11 12 BD23 10 B 1 2 12 13 BD25 11 A 3 4 13 14 BD27 11 B 1 2 14 15 BD29 12 A 3 4 15 16 BD31 12 B 1 2...

Page 224: ...1 2 6 7 BD14 8 A 3 4 7 8 BD16 8 B 1 2 8 9 BD18 9 A 3 4 9 10 BD20 9 B 1 2 10 11 BD22 10 A 3 4 11 12 BD24 10 B 1 2 12 13 BD26 11 A 3 4 13 14 BD28 11 B 1 2 14 15 BD30 12 A 3 4 15 16 BD32 12 B 1 2 16 17 B...

Page 225: ...LE SPECIFICATION RG 188 A u 50 j ohm coaxial cable CABLE UNIT COLOUR CODE CABLE LENGTH 20 mtrs SOURCE TERMINATION PART NO MCC BPSCB207 XXX MCC BPPOH207 XXX DESTINATION TERMINATION NO Same as source te...

Page 226: ...Chapter 10 226 C DOT DSS MAX XL...

Page 227: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 227...

Page 228: ...BC07 6 B4 4 5 BC09 7 B3 5 6 BC11 7 B4 6 7 BC13 8 B3 7 8 BC15 8 B4 8 9 BC17 9 B3 9 10 BC19 9 B4 10 11 BC21 10 B3 11 12 BC23 10 B4 12 13 BC25 11 B3 13 14 BC27 11 B4 14 15 BC29 12 B3 15 16 BC31 12 B4 16...

Page 229: ...6 B4 4 5 BD10 7 B3 5 6 BD12 7 B4 6 7 BD14 8 B3 7 8 BD16 8 B4 8 9 BD18 9 B3 9 10 BD20 9 B4 10 11 BD22 10 B3 11 12 BD24 10 B4 12 13 BD26 11 B3 13 14 BD28 11 B4 14 15 BD30 12 B3 15 16 BD32 12 B4 16 17 BD...

Page 230: ...1 Refer Table No 10 25 for uu vv xx yy CABLE DESCRIPTION Shielded digital cable 4 pairs 32 0 2mm black colour PVC wire CABLE UNIT COLOR CODE GREY CABLE LENGTH Digital cable 4x25 m excluding unsheathe...

Page 231: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 231...

Page 232: ...Chapter 10 232 C DOT DSS MAX XL...

Page 233: ...hundred metres These parts are required to be connected as shown in Fig 10 47 a 10 47 b Connections for Digital Trunk Cable CM XL end using 4 pair cable Table 10 25 Cable No s for Different RBM No s...

Page 234: ...1 Blue xx White uu Bl 2 Orange xx White uu O 2 3 Green xx White uu G 4 Brown xx White uu Br 5 Blue yy White vv Bl 6 Orange yy Brown vv White vv O 7 Green yy White vv Br White vv G Note i For the value...

Page 235: ...board should be assembled with shrouds latch frames and latches at site Detail of Reference Clock Cable C DOT ASSY NO ACB NSCERCKN 000 DRAWING NO FIG 10 47 c 10 47 d CABLE PART NO MCA PVCTPS04 401 CAB...

Page 236: ...Chapter 10 236 C DOT DSS MAX XL CABLE UNIT MARKER N VARIES FROM 0 TO 2 DESIGN DSSMAX MAX XL MAX XLIM MXI RCC...

Page 237: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 237 DESIGN DSSMAX MAX XL MAX XLIM MXI RCCC...

Page 238: ...ECTOR B TAB TO RETAIN 3 CONNECTOR J27 NSC 0 J46 NSC 1 TAB TO RETAIN 3 12 MTRS Note See Fig 10 47 c 10 47 d 10 6 13 CM Intra Rack Cables In this section all the internal cables of CM XL are briefly cov...

Page 239: ...S 1 AD01 ACB CMXLAD01 001 5 J33 5 J41 08 Cms 2 AD02 ACB CMXLAD02 001 5 J34 5 J42 08 Cms 3 AD03 ACB CMXLAD03 001 6 J22 6 J30 08 Cms 4 AD04 ACB CMXLAD04 001 6 J23 6 J31 08 Cms 5 DA01 ACB CMXLDA01 001 5...

Page 240: ...Chapter 10 240 C DOT DSS MAX XL...

Page 241: ...06 ACB CMXLCG06 001 CF 2 S 07 CF 3 S 06 28 Cms 7 CG07 ACB CMXLCG07 001 CF 3 S 03 3 FT 01 16 Cms 8 CG08 ACB CMXLCG08 001 CF 3 S 07 3 FT 06 16 Cms 9 CG09 ACB CMXLCG09 001 CF 3 S 07 CF 4 S 06 28 Cms 10 C...

Page 242: ...Chapter 10 242 C DOT DSS MAX XL...

Page 243: ...000 5 J11 3 04 A J 02 280 Cms 11 CK11 ACB CMXLCK11 000 5 J20 4 24 B J 06 280 Cms 12 CK12 ACB CMXLCK12 000 5 J12 3 04 A J 01 280 Cms 13 CK13 ACB CMXLCK13 000 5 J57 2 24 A J 01 320 Cms 14 CK14 ACB CMXLC...

Page 244: ...Chapter 10 244 C DOT DSS MAX XL...

Page 245: ...001 6 J3 6 J48 60 Cms 2 DL02 ACB CMXLDL02 001 6 J14 6 J37 60 Cms 3 DL03 ACB CMXLDL03 001 6 J8 5 J49 60 Cms 4 DL04 ACB CMXLDL04 001 6 J7 5 J32 60 Cms 5 DL05 ACB CMXLDL05 001 6 J18 5 J29 60 Cms 6 DL06...

Page 246: ...Chapter 10 246 C DOT DSS MAX XL...

Page 247: ...B13 ACB CMXLEB13 000 2 11 J 03 3 11 J 01 30 Cms 14 EB14 ACB CMXLEB14 000 3 11 J 03 2 11 J 01 50 Cms 15 EB15 ACB CMXLEB15 000 2 12 J 03 3 12 J 01 30 Cms 16 EB16 ACB CMXLEB16 000 3 12 J 03 2 12 J 01 50...

Page 248: ...Chapter 10 248 C DOT DSS MAX XL...

Page 249: ...B 1 1 26 B 1 142 Cms 13 EC13 ACB CMXLEC13 000 2 26 B 4 1 02 A 4 140 Cms 14 EC14 ACB CMXLEC14 000 2 26 B 3 1 02 A 3 144 Cms 15 EC15 ACB CMXLEC15 000 2 26 B 2 1 02 B 4 132 Cms 16 EC16 ACB CMXLEC16 000...

Page 250: ...Chapter 10 250 C DOT DSS MAX XL...

Page 251: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 251...

Page 252: ...ER12 ACB CMXLER12 000 FB 21 J 03 FB 22 J 02 12 Cms 13 ER13 ACB CMXLER13 000 FB 22 J 03 6 12 AB W 01 100 Cms 6 12 AB W 02 6 11 AB W 01 25 Cms This cable is single cable with multiple connectors in a da...

Page 253: ...1 150 Cms 5 15 AB W 02 5 21 AB W 01 60 Cms 5 21 AB J 02 4 24 B J 04 130 Cms 34 ER34 ACB CMXLER34 000 4 24 B J 03 4 24 A J 04 60 Cms 35 ER35 ACB CMXLER35 000 4 24 A J 03 3 22 AB J 02 130 Cms 36 ER36 AC...

Page 254: ...Chapter 10 254 C DOT DSS MAX XL...

Page 255: ...SLOT CONNECTOR POSITION NUMBER LENGTH REMARKS 1 FE01 ACB CMXLFE01 000 6 J1 TH FFB J 01 250 Cms T Top Flat Assy 2 FE02 ACB CMXLFE02 000 6 J54 TH FFB J 28 250 Cms EF M B Route the above cables along the...

Page 256: ...8 15 Cms 5 FN05 ACB CMXLFN05 000 TH FN 05 TH FFB J 10 30 Cms 6 FN06 ACB CMXLFN06 000 TH FN 06 TH FFB J 11 15 Cms 7 FN07 ACB CMXLFN07 000 TH FN 07 TH FFB J 17 30 Cms 8 FN08 ACB CMXLFN08 000 TH FN 08 TH...

Page 257: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 257...

Page 258: ...25 106 Cms Copy 1 14 MB14 ACB CMXLMB14 000 1 J30 2 J24 96 Cms Copy 1 15 MB15 ACB CMXLMB15 000 1 J27 2 J23 87 Cms Copy 1 16 MB16 ACB CMXLMB16 000 1 J24 2 J22 75 Cms Copy 1 17 MB17 ACB CMXLMB17 000 4 J1...

Page 259: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 259...

Page 260: ...Chapter 10 260 C DOT DSS MAX XL...

Page 261: ...1 285 Cms 9 MS09 ACB CMXLMS09 001 6 J9 1 J12 245 Cms 10 MS10 ACB CMXLMS10 001 6 J10 1 J14 245 Cms 11 MS11 ACB CMXLMS11 001 6 J5 1 J32 270 Cms 12 MS12 ACB CMXLMS12 001 6 J6 1 J34 270 Cms 13 MS13 ACB CM...

Page 262: ...Chapter 10 262 C DOT DSS MAX XL...

Page 263: ...Cms 5 PS 05 ACB CMXLPS05 000 3 J1 3 J29 100 Cms 6 PS 06 ACB CMXLPS06 000 3 J2 3 J30 100 Cms 7 PS 07 ACB CMXLPS07 000 4 J1 4 J37 100 Cms 8 PS 08 ACB CMXLPS08 000 4 J2 4 J36 100 Cms 9 PS 09 ACB CMXLPS09...

Page 264: ...Chapter 10 264 C DOT DSS MAX XL...

Page 265: ...25 Cms 12 PW12 ACB CMXLPW12 001 FB 12 J 01 3 M 04 35 Cms 13 PW13 ACB CMXLPW13 001 FB 13 J 01 4 M 01 25 Cms 14 PW14 ACB CMXLPW14 001 FB 14 J 01 4 M 04 115 Cms 15 PW15 ACB CMXLPW15 001 FB 15 J 01 4 M 03...

Page 266: ...Chapter 10 266 C DOT DSS MAX XL...

Page 267: ...0 5 J24 2 J6 220 Cms ADDRESS 0 2 PB02 ACB CMXLPB02 000 5 J23 2 J7 220 Cms DATA 0 3 PB03 ACB CMXLPB03 000 5 J22 3 J6 180 Cms ADDRESS 1 4 PB04 ACB CMXLPB04 000 5 J21 3 J7 180 Cms DATA 1 5 PB05 ACB CMXLP...

Page 268: ...Chapter 10 268 C DOT DSS MAX XL...

Page 269: ...0 1 22 J 02 1 05 J 01 2 22 J 02 50 Cms 9 SB09 ACB CMXLSB09 000 1 05 J 01 1 06 J 01 2 05 J 02 55 Cms 10 SB10 ACB CMXLSB10 000 1 08 J 01 1 09 J 01 2 06 J 02 70 Cms 11 SB11 ACB CMXLSB11 000 1 10 J 01 1 1...

Page 270: ...5 ACB CMXLSB25 000 4 06 J 02 4 07 J 02 3 15 J 02 95 Cms 26 SB26 ACB CMXLSB26 000 4 08 J 02 4 09 J 02 3 16 J 02 90 Cms 27 SB27 ACB CMXLSB27 000 4 10 J 02 4 11 J 02 3 17 J 02 85 Cms 28 SB28 ACB CMXLSB28...

Page 271: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 271...

Page 272: ...Chapter 10 272 C DOT DSS MAX XL...

Page 273: ...GTH REMARKS 1 SR01 ACB CMXLSR01 000 2 J4 1 J16 60 Cms 2 SR02 ACB CMXLSR02 000 2 J5 1 J22 60 Cms 3 SR03 ACB CMXLSR03 000 2 J26 1 J18 60 Cms 4 SR04 ACB CMXLSR04 000 2 J27 1 J20 60 Cms 5 SR05 ACB CMXLSR0...

Page 274: ...Chapter 10 274 C DOT DSS MAX XL...

Page 275: ...LENGTH REMARKS 1 SS01 ACB CMXLSS01 000 5 J16 2 04 A J 05 280 Cms 2 SS02 ACB CMXLSS02 000 5 J8 2 04 A J 06 280 Cms 3 SS03 ACB CMXLSS03 000 5 J17 3 04 A J 05 280 Cms 4 SS04 ACB CMXLSS04 000 5 J9 3 04 A...

Page 276: ...PART NO 1 Wire wrap contact block 4 Nos MCC BPWCB207 401 2 Polarised Hood 14 contact module MCC BPPOH207 401 4 Nos 3 Ring Terminal 2 5 mm2 M6 MCT ERRIN015 401 4 32 0 2mm PVC wire green MCA PVCSC512 4...

Page 277: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 277...

Page 278: ...dent SOURCE TERMINATION PART NO MCC BPCSZ006 301 32X2 IDC contact block assy MCC BPCSZ005 301 Piercing block MCC BPCSZ007 301 Universal cover MCS PHSTT002 401 Screw tapping 2x9 5 DESTINATION TERMINATI...

Page 279: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 279...

Page 280: ...Chapter 10 280 C DOT DSS MAX XL...

Page 281: ...ve 1 pair is spare CABLE LENGTH Site dependent SOURCE TERMINATION PART NO MCC BPCSZ006 301 32x2 IDC Contact Block Assy MCC BPCSZ005 301 Piercing Block MCC BPCSZ007 301 Universal cover MCS PHSTT002 401...

Page 282: ...Chapter 10 282 C DOT DSS MAX XL...

Page 283: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 283...

Page 284: ...401 2x7 Contact Block Assy MCC BPCSZ012 401 2x7 Piercing Block MCC BPCSZ013 401 Cover 2 module DESTINATION TERMINATION PART NO NA done on site CABLE UNIT COLOUR CODE White CABLE UNIT DESCRIPTION 8 pai...

Page 285: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 285...

Page 286: ...Chapter 10 286 C DOT DSS MAX XL...

Page 287: ...endent site dependent SOURCE TERMINATION PART NO MCC BPCSZ011 401 MCC BPCSZ012 401 MCC BPCSZ013 401 DESTINATION TERMINATION PART NO NA done at site SOURCE As per Table 10 44 PLACEMENT TAB NO RETAINED...

Page 288: ...Chapter 10 288 C DOT DSS MAX XL...

Page 289: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 289...

Page 290: ...LENGTH site dependent Site dependent SOURCE TERMINATION PART NO MCC BPCSZ011 401 MCC BPCSZ012 401 MCC BPCSZ013 401 DESTINATION TERMINATION PART NO NA done on site SOURCE As per Table 10 44 PLACEMENT...

Page 291: ...CABLE PREPARATION AND LAYING INSTALLATION MANUAL 291 DESIGN DSSMAX MAX XL MAX XLIM MXI TTCL...

Page 292: ...Chapter 10 292 C DOT DSS MAX XL...

Page 293: ...E LENGTH Site dependent SOURCE TERMINATION PART NO 1 Wire wrap contact block 4 Nos MCC BPWCB207 401 2 Polarised Hood 14 contact module MCC BPPOH207 401 4 Nos 3 Ring Terminal 2 5 mm 2 M6 MCT ERRIN015 4...

Page 294: ...Chapter 10 294 C DOT DSS MAX XL...

Page 295: ...rey XX 1 1 21 A 1 2 AA22 Black XX 1 1 22 A 1 2 AA23 Pink XX 1 1 23 A 1 2 AA24 Green XX 1 1 24 A 1 2 3 ACB MAXXA003 000 A003 NN AA03 White XX 1 2 3 A 1 2 AA04 Yellow XX 1 2 4 A 1 2 AA05 Brown XX 1 2 5...

Page 296: ...1 2 AA06 Blue XX 1 4 6 A 1 2 AA07 Grey XX 1 4 7 A 1 2 AA08 Black XX 1 4 8 A 1 2 AA09 Pink XX 1 4 9 A 1 2 AA10 Green XX 1 4 10 A 1 2 8 ACB MAXXA008 000 A008 NN AA17 White XX 1 4 17 A 1 2 AA18 Yellow X...

Page 297: ...2 2 19 A 1 2 AA20 Blue XX 2 2 20 A 1 2 AA21 Grey XX 2 2 21 A 1 2 AA22 Black XX 2 2 22 A 1 2 AA23 Pink XX 2 2 23 A 1 2 AA24 Green XX 2 2 24 A 1 2 13 ACB MAXXA013 000 A013 NN AA03 White XX 2 3 3 A 1 2...

Page 298: ...1 2 AA05 Brown XX 2 5 5 A 1 2 AA06 Blue XX 2 5 6 A 1 2 AA07 Grey XX 2 5 7 A 1 2 AA08 Black XX 2 5 8 A 1 2 AA09 Pink XX 2 5 9 A 1 2 AA10 Green XX 2 5 10 A 1 2 18 ACB MAXXA018 000 A018 NN AA17 White XX...

Page 299: ...17 A 1 2 AA18 Yellow XX 3 1 18 A 1 2 AA19 Brown XX 3 1 19 A 1 2 AA20 Blue XX 3 1 20 A 1 2 AA21 Grey XX 3 1 21 A 1 2 AA22 Black XX 3 1 22 A 1 2 AA23 Pink XX 3 1 23 A 1 2 AA24 Green XX 3 1 24 A 1 2 23...

Page 300: ...2 27 ACB MAXXA027 000 A027 NN AA03 White XX 3 4 3 A 1 2 AA04 Yellow XX 3 4 4 A 1 2 AA05 Brown XX 3 4 5 A 1 2 AA06 Blue XX 3 4 6 A 1 2 AA07 Grey XX 3 4 7 A 1 2 AA08 Black XX 3 4 8 A 1 2 AA09 Pink XX 3...

Page 301: ...6 8 A 1 2 AA09 Pink XX 3 6 9 A 1 2 AA10 Green XX 3 6 10 A 1 2 32 ACB MAXXA032 000 A032 NN AA17 White XX 3 6 17 A 1 2 AA18 Yellow XX 3 6 18 A 1 2 AA19 Brown XX 3 6 19 A 1 2 AA20 Blue XX 3 6 20 A 1 2 A...

Page 302: ...2 23 A 1 2 BB24 Black XX 1 2 24 A 1 2 BB25 Pink XX 1 2 25 A 1 2 BB26 Green XX 1 2 26 A 1 2 37 ACB ISTUB005 000 B005 NN BB05 White XX 1 3 5 A 1 2 BB06 Yellow XX 1 3 6 A 1 2 BB07 Brown XX 1 3 7 A 1 2 BB...

Page 303: ...PI07 XX 1 2 7 A 1 PI09 XX 1 2 9 A 1 PI11 XX 1 2 11 A 1 42 ACB ISTUPR07 000 PR07 NN PI19 XX 1 2 19 A 1 PI21 XX 1 2 21 A 1 PI23 XX 1 2 23 A 1 PI25 XX 1 2 25 A 1 43 ACB ISTUPR09 000 PR09 NN PI05 XX 1 3...

Page 304: ...and side as viewed from front of exchange side Similarly on the Line side module label holder is mounted on the bottom side 8 cable units 8 pairs each of 64 pair cable are terminated on 8 disconnectio...

Page 305: ...rticals E M Trunks of TU 1 in BM5 will be terminated on V13 1 to V13 7 Each backmount frame can accommodate 2 EMF cards Detail of termination is given in Fig 10 51 b A maximum of 14 EMF cards can be t...

Page 306: ...ACB MAXXBPTX 000 BPU SCU HPU See sec 10 6 4 VDU 8 DFXX XX 11 to 26 ACB MAXLDFXX 000 Suite MCB s FBI Card 1mm2 9 DGUX X 1 to 4 DCDP s FBI 2 5mm2 10 DPUX X 1 to 4 DCDP s FBI 2 5mm2 11 DTXX XX 1 to 4 AC...

Page 307: ...GCP5 000 DCDP2 Chassis gnd do suite5 do do 32 GDIP ACB MAXLGDIP 000 DCDP1 chassis digital gnd IOP PDP digital GND do do 33 GDP1 ACB MAXLGDP1 000 DCDP1 digital gnd PDP digital gnd suite1 do do 34 GDP2...

Page 308: ...CDP1 48V gnd 240 mm2 Single core power cable Red 58 PGD2 ACB MAXLPGD2 000 IDP 48V gnd DCDP2 48V GND 240 mm2 Single core power cable Red 59 PGF1 ACB MAXLPGF1 000 DCDP1 FBI Card J32 IOP PDP FBI card J42...

Page 309: ...gle core power cable 80 PLXX XX ACB MAXLPLXX 000 As per Table 10 5 120 mm2 Blue do 81 PMG1 ACB MAXLPMG1 000 IOP PDP OMA 48V and Pin of TB2 2 5 mm2 82 PMP1 ACB MAXLPMP1 000 IOP PDP OMA 48V Pin of TB1 2...

Page 310: ...ar IOP PDP FBI Card J41 2 5mm2 Blue PVC insulated cable 104 PPV2 ACB MAXLPPV2 000 do FBI Card J43 2 5mm2 Blue PVC Insulated cable 105 PRI0 ACB IOPHPRI0 000 IOP0 VHI ACIO I Printer1 8 Pair Cable 106 PR...

Page 311: ...Y4 000 IOPI VHI ASIO4 CRP Terminal 8 pair Teleph Cable from IOP to VDU Terminals 120 TEY5 ACB IOPHTEY5 000 IOPI VHI ASIO5 CRP Terminal 8 pair Teleph Cable from IOP to VDU Terminals 121 TEY6 ACB IOPHTE...

Page 312: ...ards and the filter boxes of TUs In IOP input fuse is present In ADP fuse is present only in the power supply card FBI cards mounted on DCDPs IOP PDP and suite PDPs contain two fuses each MCBs HRC fus...

Page 313: ...pe Qty Used Part Code 1 2 Amp Slow blow fuse 1 EFF 00002000 000 11 6 FUSES USED IN CM XL Sl No Fuse MCB Rating Type Qty Reqd Part Code Card 1 1 6Amp Slow blow fuse 2 EFS 00001600 000 FFB 2 500 mA do 6...

Page 314: ...0 Amp MCB 10 EBB C0100120 110 3 400 mA Slow blow fuse 1 EFS 00000400 000 4 2 Amp Slow blow fuse 1 EFS 00002000 000 11 10 CONSOLIDATED LIST OF FUSES AND MCBS Sl No Rating Type Unit Location Code Physic...

Page 315: ...OP PDP IOP PDP 11 16 Amp HRC fuse Suite PDP Suite PDP 12 36 Amp HRC Fuse Suite PDP Suite PDP 13 30 Amp MC B DCDP DCDP 14 120 Amp MCB DCDP DCDP Fuses Used in ISTU Sl No Rating Type Unit Location Code P...

Page 316: ...INSTALLATION MANUAL 316 Chapter 12 Operator Positions Information will be provided later...

Page 317: ...2 is tapped from DCDP1 and for inverter 3 from DCDP2 However if DCDP2 is not installed inverter 3 may also be connected to DCDP1 13 3 INVERTER OUTPUT SUPPLY DISTRIBUTION The arrangement of distributi...

Page 318: ...Chapter 13 318 C DOT DSS MAX XL...

Page 319: ...bution of inverters to VDUs and printers can be given as per the table 13 1 In case of failure of any one of the inverters supply can be trapped from the nearest inverter Note Inverters output ground...

Page 320: ...N WRITING has to be put at site to identify a particular cabinet The format used for this purpose is explained below This is also supported by fig 14 1 14 2 14 2 SIGN WRITING FORMAT ON EVERY SUITE Ver...

Page 321: ...SIGN WRITING INSTALLATION MANUAL 321...

Page 322: ...Chapter 14 322 C DOT DSS MAX XL...

Page 323: ...ny repair 15 2 VDU SETTING Switch ON the VDU terminal and enter setup mode by pressing F3 There are seven different set ups listed below i Display Set up ii Special Set up iii General Set up iv Commun...

Page 324: ...Set up _ _ x x CR pad off Edit Arrow PF Keys Active iii General Set up VT200 mode 7 bit controls VT200 ID User defined keys locked User features unlocked Standard mode Numeric key pad Normal cursor k...

Page 325: ...nnect 2s delay Limited transmit v Printer Set up Speed 9600 Normal print mode X off 8 bits no parity 1 stop bit Print full page Print National only No terminator vi Keyboard Set up Typewriter keys Cap...

Page 326: ...ntervals of 8 15 3 PRINTER SETTING Setting Communication between IOP and Printer requires the following Baud rate 9600 Databits 8 Parity No Parity Stop bits 1 Following is a typical example of switch...

Page 327: ...VDU PRINTER SETTING INSTALLATION MANUAL 327 2 5 UP 2 6 UP 2 7 DOWN 2 8 DOWN Note UP means ON DOWN means OFF...

Page 328: ...instruction required is whether the jumper position needs to be shorted or not to be shorted Example In APC MSC014 F S07 W1 and W4 are two pin Jumpers W1 To be shorted W4 Not to be shorted 3 Pin Jumpe...

Page 329: ...iagram AD of the respective cards can be referred to 16 3 JUMPER SETTINGS IN BM XL LM Following are the card types with current versions requiring jumper settings used in BM LM and their respective sl...

Page 330: ...22 to W29 b c or 2 3 For single ended links 16 3 3 APC BME442 H S02 Jumpers W1 W4 should be shorted W2 W3 Jumpers are to be left open 16 3 4 APC TIC002 F S10 W1 should be shorted for 27C512 in U75 W1...

Page 331: ...PC MFC043 F S08 JUMPER SHORTING POSITION W5 Top 1 2 W6 Right 2 3 W7 Bottom 2 3 16 3 8 APC TGA077 T S02 JUMPER SHORTING POSITION W1 Horizontal b c W2 Horizontal b c 16 3 9 APC TSC008 F S06 JUMPER SHORT...

Page 332: ...C TUC046 T S03 JUMPER SHORTING POSITION W2 Bottom b c 16 3 12 APC TUB003 T M04 JUMPER SHORTING POSITION FUNCTION W1 W3 Left For TUX1 Right For TUX2 Left For TUX3 Right For TUX4 W2 W4 Right For TUX1 Ri...

Page 333: ...13 W14 W16 04 4 W9 W10 W11 W12 W13 W16 06 5 W9 W10 W11 W12 W13 W14 W15 08 6 W9 W10 W11 W12 W13 W15 0A 7 W9 W10 W11 W12 W13 W14 0C 8 W9 W10 W11 W12 W13 0E 9 W10 W11 W12 W13 W14 W15 W16 10 10 W10 W11 W1...

Page 334: ...4 W15 W16 30 26 W11 W12 W13 W15 W16 32 27 W11 W12 W13 W14 W16 34 28 W11 W12 W13 W16 36 29 W11 W12 W13 W14 W15 38 30 W11 W12 W13 W15 3A 31 W11 W12 W13 W14 3C 32 W11 W12 W13 3E Note The mentioned jumper...

Page 335: ...W19 W20 W22 W23 W24 11 10 W18 W19 W20 W23 W24 13 11 W18 W19 W20 W22 W24 15 12 W18 W19 W20 W24 17 13 W18 W19 W20 W22 W23 19 14 W18 W19 W20 W23 1B 15 W18 W19 W20 W22 1D 16 W18 W19 W20 1F 17 W17 W19 W20...

Page 336: ...SB to be left open 16 3 15 Jumper Settings for ISTU Motherboard Part Code APC ILM403 H M00 Only ITC ID an ICC ID jumpers to be put according to the ISTU position Other jumpers to be left open Note Bit...

Page 337: ...JUMPER SETTINGS INSTALLATION MANUAL 337 ICC ID C2 ii When ISTU is in 3rd TU position ITC ID B0 ICC ID C4...

Page 338: ...t W10 W14 W15 short W1o o W9 o o W2 o o W10 o o W3 o o W11 o o W4 o o W12 o o W5 o o W13 o o W6 o o W14 o o W7 o o W15 o o ICC ITC 16 3 16 Jumper Settings for SUM Unit 16 3 16 1 a SUM jumper ID should...

Page 339: ...ollows W2 W3 should be shorted and W1 W4 to be left open 16 4 JUMPER SETTINGS IN CM XL Following are the card types with current versions requiring jumper settings used in CM XL and their respective s...

Page 340: ...1 2 of W1 and W4 are to be shorted For BPU SCU HPU and 7SU with BPC W2 W3 jumpers are to be left open Pin Nos 1 2 of W2 and W3 are to be shorted for 7SU with HPC W1 W4 to be left open 16 4 4 APC CBX38...

Page 341: ...JUMPERS In all slots Jumpers W11 W21 W22 W24 are to be shorted Rest of the Jumpers are to be left open 16 5 JUMPER SETTINGS IN IOP 16 5 1 APC VHC358 O S00 Jumpers W13 W14 W15 W17 W18 are to be shorted...

Page 342: ...Chapter 16 342 C DOT DSS MAX XL...

Page 343: ...JUMPER SETTINGS INSTALLATION MANUAL 343...

Page 344: ...Chapter 16 344 C DOT DSS MAX XL...

Page 345: ...ossible The movement of cards into the slots should be free There should not be any shorting of any pin in the Euro connector 96 pins at the back plane as well as at the front side where we insert the...

Page 346: ...nto the slots at this stage There should not be any loose fitting of fuses in PDPs and filter boxes and FBI cards All filter boxes should be properly mounted Shorting stubs on FBI cards should be thor...

Page 347: ...ts termination to FBI Card corresponding to the particular BM or CM or LM FBI Card jumper setting should be verified For CM FFB on top hat jumper settings should be verified also to detect fan failure...

Page 348: ...ing Bus Termination Unit BTU Testing Space Switch Unit SSU Testing BM Testing through CM System Initialisation in Different Configurations Inter BM Testing Alarm Testing System Stability Load Testing...

Page 349: ...some time so that few blocks of code are loaded i e 0K 36K 72K Hence AP 0 IOP 0 link is tested 6 Press reset on AP 0 link between AP 0 IOP 0 is broken AP 1 should take over code loading with both mem...

Page 350: ...erchange the AP no unit should go to suspect 4 Make AP 1 OOS OPR AP 0 should be INS ACT check the alarm on ADP for AM 5 Repeat step 2 for AP 1 18 4 2 Memory Diagnostics Set up Same as in 18 4 1 1 Make...

Page 351: ...wer on tests for SSC 0 and SSC 1 are successfully completed 3 Give reset on SSC 1 and make sure that SSC 0 has started code loading Check the message on SSC 0 terminals for both ports enabled i e it h...

Page 352: ...e 14 Make CMS1 OOS OPR 15 Give soft start to CM CM should come up through only available CMS2 16 Bring CMS1 inservice 17 Interchange SSC 18 Repeat step 11 to 16 19 Interchange AP 20 Repeat step 3 to 1...

Page 353: ...epeat step 3 for MU 1 6 Interchange SSC 7 Repeat steps 2 to 6 with SSC 1 active 18 6 3 Clock Diagnostics Same as in 18 6 1 Set up 1 Make SSC 0 INS ACT SSC 1 INS SBY 2 Make CLK 0 OOS OPR CLK 1 INS ACT...

Page 354: ...p with all units of AM and CM inservice 3 If any unit is Out Of Service OOS then run diagnostics for that unit and bring it inservice by PUT SWU INS command 18 8 1 IFC PSM ESM Diagnostics Bus Terminal...

Page 355: ...FUNCTIONAL TESTING INSTALLATION MANUAL 355...

Page 356: ...0 1 15 16 8 12 9 0 1 17 18 9 15 10 0 1 19 20 10 16 11 0 1 21 22 11 17 12 0 1 23 24 12 18 13 0 1 25 26 13 19 14 0 1 27 28 14 20 15 0 1 29 30 15 21 16 0 1 31 32 16 22 17 1 4 1 2 17 5 18 1 4 3 4 18 6 19...

Page 357: ...and 3 for all other PSM IFC cards which are equipped 5 Interchange SSC 6 Repeat step 2 to 4 for all IFC cards with SSC 1 active 18 9 SSU TESTING Set up CM is fully initialised and BM CM cables are co...

Page 358: ...ane IDs and Sec 16 3 13 and 16 3 14 for setting these ids TABLE 18 2 Back Plane IDs for Base Modules S No Base Module Number Back Plane id Copy 0 BPU in Decimal Hex Back Plane id Copy 1 BPU in Decimal...

Page 359: ...0x38 57 0x39 30 30 58 0x3A 59 0x3B 31 31 60 0x3C 61 0x3D 32 32 62 0x3E 63 0x3F Note i Shorting of Pins at Back Plane represents 0 ii Opening of Pins at Back Plane represents 1 iii Base Module number...

Page 360: ...hould get a path 9f 67 check the message on BP terminal 10 Give a reset to TSC 1 i e 9f now BM should get path 9e 67 Code load in Base Module will take place but BM will not fully initialise unless it...

Page 361: ...e as SU using equip frame command Connect VDU terminals on SU7 0 and SU7 1 controllers through BP terminal cable for SUM Switch on the power supplies and ensure the power on tests for SU7 0 and SU7 1...

Page 362: ...ice and interchange should be smooth Test set details for BRI PRI are available in Appendix A of the maintenance procedure document 18 12 SYSTEM INITIALISATION IN DIFFERENT CONFIGURATIONS Set up Both...

Page 363: ...0 OOS OPR for BM3 i e IFC2 and IFC17 should be OOS OPR Now make inter BM calls calls should be successful and check speech Bring IFC2 and IFC17 inservice 6 Make inter BM calls in all BMs and check vo...

Page 364: ...eared 3 Repeat steps 1 to 2 for all other PSU cards of BTU0 and BTU1 taking one at a time 18 14 4 SSU Alarm Test Set up A duplex system 1 Switch off one PSU of plane 0 of SSU0 Alarm should be raised o...

Page 365: ...put swu ins for AP 1 frc swu ins for AP 1 put swu oos for MU 0 put swu ins for MU 0 frc swu ins for MU 0 put swu oos for MU 1 put swu ins for MU 1 frc swu ins for MU 1 Interchange AP put swu oos for M...

Page 366: ...u oos for CMS3 C put swu ins for CMS3 frc swu ins for CMS3 put swu oos for CMS4 D put swu ins for CMS4 frc swu ins for CMS4 put swu oos for CLK 0 E put swu ins for CLK 0 frc swu ins for CLK 0 put swu...

Page 367: ...frc swu ins for BP 1 put swu oos for BMS 0 C put swu ins for BMS 0 frc swu ins for BMS 0 put swu oos for BMS 1 D put swu ins for BMS 1 frc swu ins for BMS 1 put swu oos for SCIC 0 E put swu ins for S...

Page 368: ...nd trunks of all types for testing the equipped terminals NN is the number of base module equipped 18 16 LOAD TESTING Set up A duplex system System is completely initialised in full configuration with...

Page 369: ...th NSC AO1 Card Level 2 clock in SCU frame of CM XL supports network synchronisation with TAX clock or higher order atomic clock In this case data transfer rate through modems yields very good through...

Page 370: ...Chapter 18 370 C DOT DSS MAX XL...

Page 371: ...IOP say IOP 0 to Warm start level using init iop command 2 IOPXX cd u admn cmdfile 3 Invoke utility conv_cmd with physical bm no in a command line parameter e g to equip BM No 5 give IOPxx sh conv_cm...

Page 372: ...eneration can be done PROCEDURE TO BE FOLLOWED FOR PREPARATION OF DATA 13 Invoke crp Refer note 1 below for information about the following command files crp Create the command files through CRE CMD F...

Page 373: ...and files are optional i e these are to be used if some hunt groups or service groups are to be created or if some extra features are to be granted to subscribers WARNINGS The given order of command f...

Page 374: ...d command file for modifying day type acsgp cmd command file for creating service group acsrt cmd command file for creating special routes acslv cmd command file for making a lvn supervisor amsdr cmd...

Page 375: ...commands to be given are MOD SYS PARM PAR NAM OWN STD LEN PAR VAL 5 CRE SPL ROUT RUT COD 017932 RUT FLG 1 CNB NA GA CRG RTN 1 8 ILT Y Note 3 For Satellite Exchange Routes may be created in a similar m...

Page 376: ...ter port 7 or port 8 only has to be used but for CLI alone any port can be used after making following modifications in that particular port only Cuts and strap indicated in Fig AII 1 AII 2 AII 3 are...

Page 377: ...v There can be more than one ISTU in any configuration if required v The corresponding cables coming from time switch to TU should be terminated as given below TTXX Cable Position in TU TTXX Cable Pos...

Page 378: ...a maximum of 3 cables may be prepared Two nos of ICs 26 LS31 are to be mounted on DTS 066 T S04 card and straps to be done as per the strap list given This DTS card is to be used in digital trunk slot...

Page 379: ...U104 1 S13 Connect U113 15 to U113 9 S3 Connect U113 2 to Ba19 S14 Connect U113 9 to U113 8 S4 Connect U113 3 to Bc19 S15 Connect U113 8 to U113 7 S5 Connect U104 2 to Ba20 S16 Connect U113 7 to Aa1...

Reviews: