13
Filter
600, 800, & 1000L Models
The 600, 800, & 1000L Goldline models have a suction filter with built in isolation valve.
To isolate the filter for cleaning, push and turn the yellow handle 90
on the base of the filter bowl to withdraw
valve to shut off tank flow and then remove filter bowl and element.
When filter bowl and element has been replaced, tighten bowl nut and refit shutoff valve to filter, push in and turn
90
to lock in place.
MAINTENANCE
After Use
o
At the end of spraying, flush the system (using the tank rinsing system if fitted) three times with fresh
water. Finish with a final rinse using C-Dax Neutralise rinsing solution. Include the spraying device/s in
this operation.
o
Drain tank using remote drain bung.
o
Remove the strainer basket under the lid of the sprayer, rinse and refit.
o
Isolate filter using gate valve or filter isolation bung.
o
Remove the main filter element, clean and refit, ensuring that the filter bowl O-ring is in place, and the
bowl nut is tight. Replace element if damaged or unable to be cleaned.
o
Clean the outside of the sprayer to remove any spray residue.
o
Lubricate the control unit levers
o
Remove and clean spray tips and nozzle filters on spray boom (if fitted).
o
Fully extend the extension legs after use to maintain stability.
Routinely
o
Check calibration of sprayer and boom (if fitted).
o
Lubricate any moving boom or accessory parts.
o
Lubricate drive shaft.
o
Check spray hoses for kinks or damage, replace if necessary.
o
Check pump accumulator pressure
o
Check the oil level and condition in the spray pump.
Annually or End of Season
o
Replace oil in spray pump (or after 200 hours, which ever comes first). Use SAE 30 antifoam oil
o
Replace nozzles on spray boom
o
Flush tank sprayer completely. Only water to be left in the system.
600L, 800L, &
1000L Filter