![C-COR Flex Max901e Equipment Manual Download Page 14](http://html1.mh-extra.com/html/c-cor/flex-max901e/flex-max901e_equipment-manual_3080022014.webp)
1
1-4
Flex Max901e 1GHz Trunk and Bridger Amplifiers
1502154 Rev D
Part Numbers (Model Options)
Flex Max901e Trunk Amplifiers
1
2
3
4
5
6
7
8
9
10
11
12
F
M
T
E
x
x
x
–
x
x
x
x
x
x
x
N
1
Series
E
Flex Max901e series
a
a) 15A current passing capability.
2
Tilt Configuration
D
Equal trunk and bridger tilt
a
G
Optimized tilt for 1GHz operation
b
a) Must choose “
5
” in #3 block,
Spacing
. Suitable for replacement of
FNT7, FNT8, and FNT9 series amplifiers
b) Must choose “
8
” in #3 block,
Spacing
.
3
Spacing
5
32dB
a
8
33dB
b
a) 18dB factory equalization. Must choose “
D
” in #2 block,
Bandwidth
.
b) 13dB factory equalization. Must choose “
G
” in #2 block,
Bandwidth
.
4
Frequency Split
J
42/54MHz
N
65/85MHz
Q
55/70MHz
5–6 Level Control
K0
427.25MHz NTSC TV
KB
439.25MHz NTSC TV
KC
451.25MHz NTSC TV
KL
423.25MHz NTSC TV
KN
471.25MHz NTSC TV
L0
499.25MHz NTSC TV
L4
495.25MHz NTSC TV
MB
645.00MHz QAM
RM
711.00MHz QAM
SD
609.00MHz QAM
7
Return
3
14.5dB active gain
a
6
18dB active gain
b
7
18dB active gain with return switches
c
a) Select "
D
" in #2 block,
Bandwidth
.
b) Select "
7
" if future element management transponder is planned.
c) Operation of return switches requires a transponder.
8
Output Configuration
F
Trunk with two bridger outputs—user-configurable to
4 outputs with
–25dB External
testpoints
a, e
H
Trunk with two bridger outputs—user-configurable to
4 outputs with
–20dB Internal
testpoints
b, e
P
Trunk with two bridger outputs—user-configurable to
4 outputs with
–20dB External
testpoints
c, e
S
Trunk with two bridger outputs—user-configurable to
4 outputs with
–25dB Internal
testpoints
d, e
a) Select "
A
", "
F
", or "
L
", in #10 block,
Housing
.
b) Select "
A
", "
C
", or "
K
" in #10 block,
Housing
.
c) Select "
A
", "
F
", or "
L
" in #10 block,
Housing
.
d) Select "
A
", "
C
", or "
K
" in #10 block,
Housing
.
e) Plug-in splitters and directional couplers must be ordered separately.
9
Powering
1
None
a
6
2.3A, 90V, 50/60Hz, H.E. transformerless
b
a) Select “
A
” in #10 block,
Housing
. Required when ordering RF module
only.
b) 40–90 V operating range; includes detachable cable.
10
Housing
A
None
a
C
6-port Flex Max, 1GHz,
Internal
testpoints
b
F
6-port Flex Max, 1GHz,
External
testpoints
c
K
6-port Flex Max, 1GHz, four 90° access ports,
Internal
testpoints
b
L
6-port Flex Max, 1GHz, four 90° access ports,
External
testpoints
c
a) Select “
1
” in #11 block,
Housing Finish
. Required when ordering RF
module only.
b) Select “
H
” or “
S
” in #8 block,
Output Configuration
.
c) Select “
F
” or “
P
” in #8 block,
Output Configuration
. Forward
external testpoints only.
11
Housing Finish
1
Standard (or N/A)
a
4
Corrosion protected
a) Required when ordering RF module only.
12
Element Management
N
EMS capable
a, b
a) Transponder sold separately:
AM protocol (P/N 810-0354-01A)
HMS protocol (P/N 810-0354-01H)
b) Must order mounting bracket kit (P/N 1501024)
Summary of Contents for Flex Max901e
Page 2: ......
Page 3: ...Flex Max901e 1GHz Amplifiers Trunks FMTE and Bridgers FMBE 1502154 Revision D...
Page 10: ...viii Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 20: ...1 1 10 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 56: ...4 4 20 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 102: ...7 7 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 142: ...B B 32 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 146: ...C C 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 160: ...D D 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 164: ...E E 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 170: ...Index 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Page 171: ......