ELECTRICAL

 

!

WARNING

: Compressor installation must be performed by a qualified electrician in accordance with the National Electri-

cal Code (NEC) or the Canadian Electrical Code (CEC), the National Electrical Safety Code (NESC) OSHA code, and/or any
local or state codes having precedence�

Be sure of proper wire sizing and that the circuit breaker and the distance from the breaker is within suggested range� Confirm your 
electrical-supply voltage matches what is required for the motor�

 

!

WARNING

: The compressor must be grounded� Grounding reduces the risk of electric shock� Certain C-Aire models are

equipped with a cord that has a grounding wire with a grounding plug� The plug must be plugged into an outlet that is
installed and grounded in accordance with all local codes and ordinances�

 

!

WARNING

: Improper installation of the grounding plug will result in a risk of electric shock� When repair or replacement of

the cord or plug is required, do not connect the grounding wire to either flat-blade terminal� The insulated wire with a green
outer surface and yellow stripes is the grounding wire�

NOTE

: The installation, electric motor, wiring, and all electrical controls must be in accordance with NFPA 70-1996 National Electric 

Code, National Electric Safety Code, and state and local codes� Failure to abide by the national, state, and local codes may result in 
physical harm and/or property damage�

 

!

DANGER

: High voltage may cause personal injury or death� Disconnect and lockout/tagout, per OSHA regulation 1910�147,

all electrical power supplies before opening the electrical enclosure or servicing�

 

!

DANGER

: Never assume a compressor is safe to work on if it is not operating� It could restart at any time� Always discon-

nect/ lockout/tagout before servicing�

 

!

CAUTION

: Dry pipe sprinkler compressor must be wired to a reliable power source to be compliant with AHJ�

WIRING DIAGRAM

S

33

 DIGITAL AMD

YELLOW

WHITE

RED

BLACK

WHITE

BLACK

GREEN

BLACK

WHITE

GREEN

BLACK

WHITE

GROUND

GROUND

DIGITAL

AMD

POWER

SOLENOID

COMPRESSOR

Summary of Contents for S33

Page 1: ...Fire Protection Air Compressor Owner s Manual REV A Dec 2 21 MODEL S33...

Page 2: ...CE 8 VALVES AND SWITCHES 8 TROUBLESHOOTING 9 WARRANTY 10 6 MANUAL DRAIN VALVE RM 260R 0050 8 3 4 OUTLET 2 SAFETY VALVE BR SV 25 70 1 AIR FILTER FA S28 10 TANK 5 DIGITAL AMD GEN 3 EL D0911 S261R K 9 JU...

Page 3: ...d air can be extremely dangerous and harmful when it is not understood or is misused PRODUCT NUMBERING SYSTEM Mount SET PRESSURE IN SECONDS IDEAL FOR QUIET SETTINGS Nursing Homes Apartments Churches I...

Page 4: ...ank air every day to decrease risk of bursting NOTE Per UL 1450 46 17 C Aire recommends a maximum of 70 duty cycle for its compressors INSTALLATION SELECTING A LOCATION C Aire compressors are to be in...

Page 5: ...anchors not included to attach mounting bracket INSTALL AIR FILTER ASSEMBLY BOLT UNIT TO MOUNTING BRACKET HANG UNIT ON MOUNTING BRACKET INSTALL MOUNTING BRACKET INLET AND DISCHARGE PIPING CAUTION Do n...

Page 6: ...ent of the cord or plug is required do not connect the grounding wire to either flat blade terminal The insulated wire with a green outer surface and yellow stripes is the grounding wire NOTE The inst...

Page 7: ...arrow buttons can perform a 1 1 change to the set value The compressor will not run in this mode If the compressor remains in this mode for 60 seconds with no adjustments it will automatically revert...

Page 8: ...24HRS 7 DAYS STARTS SETTTINGS LOCKED C P M C To lock the settings hold the M and the P simultaneously for 3 seconds until the SETTINGS LOCKED light is illuminated RUN MAX MIN PSI kPa BAR 24HRS 7 DAYS...

Page 9: ...ALLATION DIAGRAM Dry Pipe Valve System pressure varies depending on size of system Water in system Air Source Low Pressure S33R LD1 115PD No AMD Permitted Adjustable 5 55 PSI Braided Flex Hose Include...

Page 10: ...ELIEF VALVE safety valve see parts identification Pressure relief valves are standard on all units Pressure relief valves aid in preventing system failures by relieving system pressure when compressed...

Page 11: ...Clean or replace filter element Tighten joints Fuse or breaker trip Wrong size fuse or breaker Wrong size wire Motor starting under load Loose wires Compressor is being overworked Check fuse breaker s...

Page 12: ...pair service adjustment removal or replacement F Misuse or abuse G C AIRE HAS NO OBLIGATION UNDER THESE WARRANTIES OR OTHERWISE REGARDLESS OF THE FORM OF ACTION FOR SPECIAL INDIRECT CONSEQUENTIAL OR I...

Page 13: ...11...

Page 14: ...12 380 West 1st Street Dresser WI 54009 800 762 2247 651 462 3440 www cairecompressors com...

Reviews: