4.2 Module Cleaning

Excess dirt and dust accumulating on the glass surface of the

module can reduce its power output. Therefore BYD recommends
periodic cleaning of PV modules especially during times when the
modules do not have the expected power output. The cleaning process
must be implemented after the PV modules are disconnected and
cooled, and after cleaning PV modules must ensure dry ,next it are
connected. Non-professional authorized personnel are not allowed to
clean modules, and make sure they have appropriate safety equipment
for aerial work and the risk consciousness of high altitude work. Please
check the glass surface of the module for cracks and damages before
cleaning. If there are already cracks on the module, please do not clean
but inform the installer or maintenance service provider. Do not wear
metal accessories like a watch or jewelry during cleaning PV modules,
avoid the broken of modules.

4.2.1 Module Cleaning Condition

The cleaning works of PV module should be carried out at morning,

evening, overcast sky or irradiance less than 200W/m

2

. The use of cold

water to clean a PV module heated up sunshine might cause cracks in
the glass cover of the module, so strictly forbidden proceed cleaning
work during the noon or a strong period of sunlight.

4.2.2 Module Cleaning Method

Module cleaning method divided into general clean and washing

clean.

1.

General Clean

(1) To the attachment which can easy to clean like dry dust, leaves

on the PV module surface, cleaner can use dry and professional mop or
soft cloth to clean.

(2) To the attachment which are not easy to clean like mud, birds

droppings, sticky stuff on the PV module surface, cleaner can use
scraper or gauze to wipe, but avoid using hard material, to prevent
destroy glass surface. Use cleaning effect to judge whether clean or
not.

2. Washing Clean
(1) To the inorganic compound like wet dust which are not easy to

clean on the PV modules surface, cleaner can carry out general clean
(2) first, then use clean water which pressure less than 500KPa to
washing, finally, use clean gauze wipe the waterlogging. To avoid cell
micro crack or module broken, cleaner must attention the water
pressure should not too large.

(2) To the organic like animal corpse (such as mosquitoes and

flies), dung or plant sap which are closely attach to the glass surface,
cleaner can carry out general clean (2) first, then use clean water which
pressure less than 5MPa to washing meanwhile match up professional
cleaner like soft soap water or neutral disinfectant (such like alcohol,

Summary of Contents for M6C-30

Page 1: ...the Parameter of Modules d Canceled information of manufacturer Fang Shuili Han Peng 5 2014 9 5 Add manufacturer location Fang Shuili 6 2015 3 5 Add Vietnam Factory Han Peng 7 2015 8 28 Add Insertion...

Page 2: ...ule b Modify cleaning pressure c Add installation height of module Zhao bishuai Mao yonghua 15 2017 12 20 Add an equation for calculating the voltage of sting Li Shangkun 16 2018 5 23 a Modify power f...

Page 3: ...D Project No Code 2M SOP0007540 Edition 13 Page 3 30 3 Installation Manual and User Manual for BYD Photovoltaic Modules BYD COMPANY LIMITED ADD No 1 Yan an Road Kuichong Longgang District 518119 Shenz...

Page 4: ...age manual 5 3 Installation 6 3 1 Warning 6 3 2 Mechanical installation 8 3 2 1 Mounting system 8 3 2 2 Clamping 11 3 2 3 Insertion system 12 3 3 Electric installation 14 3 3 1 Grounding 14 3 3 2 Gene...

Page 5: ...en circuit voltage short circuit current weight dimensions etc 1 2 Barcode Each module has only one bar code as shown below FIG 1 Bar code SH 130701 P630 ASEC 001 SH Manufacturer location SH Shanghai...

Page 6: ...ngs fuse sizes and size of controls relating to the PV output 5 The installation work of the PV array can only be done under the protection of sun sheltering covers or sunshades and only qualified per...

Page 7: ...talled on the roof the whole system mounting should be installed around 20CM away from the roof The recommended standoff height is 20 cm The PV array installation slope should more than 5in ft 127mm 3...

Page 8: ...t least 25 years 3 2 Mechanical installation 3 2 1 Mounting system Use screws put through the mounting holes according to the following figure for fixing the module If all mounting holes are used a lo...

Page 9: ...40 35 942 860 1360 PHC 36 1992 992 50 40 35 942 800 1300 MHC 36 1992 992 50 40 35 942 800 1300 PHT 36 1948 1022 50 40 35 972 800 1300 P6E 18 1482 676 50 40 35 626 628 802 482 566 P6E 24 1325 992 50 40...

Page 10: ...f module K denotes 1500V system Voltage of module L denotes 1500V system Voltage of half cell transverse module During installation of the modules it should be made sure that all mounting holes are us...

Page 11: ...stallation diagram of four fixtures under pressure of 5400Pa TAB 3 The dimensions corresponding to fixture installation Model Measure P6C 18 P6C 24 P6C 27 P6C 30 L 1640 P6C 30 L 1650 P6C 30 L 1645 P6C...

Page 12: ...st Installation method with clamping on the short side of the frame as below FIG 8 Schematic diagram of four clamps under pressure of 2400Pa Installation method FIG 9 Schematic diagram of short side p...

Page 13: ...Guide rail installation diagram During the installation on the long side of the frame you need to take care that the cells on the front side and that the grounding holes on the back side don t get cov...

Page 14: ...of mounting modes with border thickness Thickness Installation 50mm 45mm 40mm 35mm 30mm Refer Long side bolt FIG 2 FIG 3 FIG 4 FIG 5 Long side press FIG 6 FIG 7 Long side rail FIG 10 FIG 12 FIG 13 Sho...

Page 15: ...ualified electrician and also the grounding itself must be done by a qualified electrician The ground wire should have at least the same size as the electrical conductors 10 12 AWG exposed copper wire...

Page 16: ...t be bent or crushed on the direct exit of the cable screw joint include connecter and box A minimum bending radius R 4 cable diameter must be maintained The cable must be routed in a way that tensile...

Page 17: ...be multiplied by 1 25 for C Si or non C Si we recommend the maximum number of series connected modules for each module series as stated below Type The maximum number of modules in series BYD P6E 18 37...

Page 18: ...ll be limited by the number of parallel connection We recommended the maximum number of modules is 3 The fuse protection needs to be determined as well 7 To prevent the cables and the connectors from...

Page 19: ...m corrosion A firs inspection should be carried out 12 months after installation and inspections every 10 years thereafter 2 Regularly check the electric wiring of the modules for reliable connection...

Page 20: ...to clean a PV module heated up sunshine might cause cracks in the glass cover of the module so strictly forbidden proceed cleaning work during the noon or a strong period of sunlight 4 2 2 Module Cle...

Page 21: ...rds of abnormal output in the monitoring recording analysis whether caused by leakage current or not and check whether exist damage or sticky on the modules connection and related electrical component...

Page 22: ...n operation or maintenance of the module that is important to know but it is not necessarily hazardous CAUTION A caution message indicates a potential threat to minor injury or alerts against behavior...

Page 23: ...21 37 45 8 73 BYD250P6C 30 250 30 13 8 30 37 76 8 81 BYD255P6C 30 255 30 40 8 39 38 07 8 89 BYD260P6C 30 260 30 67 8 48 38 38 8 97 BYD265P6C 30 265 30 93 8 57 38 69 9 05 BYD270P6C 30 270 31 18 8 66 3...

Page 24: ...5P6C 18 135 16 74 8 07 21 29 8 64 BYD140P6C 18 140 17 20 8 16 21 59 8 72 BYD145P6C 18 145 17 59 8 25 21 89 8 80 BYD150P6C 18 150 18 00 8 34 22 19 8 88 BYD155P6C 18 155 18 40 8 43 22 49 8 96 BYD160P6C...

Page 25: ...210 25 74 8 16 32 37 8 73 BYD215P6E 27 215 26 06 8 25 32 68 8 81 BYD220P6E 27 220 26 38 8 34 32 99 8 89 BYD225P6E 27 225 26 69 8 43 33 30 8 97 BYD230P6E 27 230 27 00 8 52 33 61 9 05 BYD235P6E 27 235 2...

Page 26: ...92 47 31 9 35 BYD350M6F 36 350 39 02 8 97 47 64 9 41 BYD355M6F 36 355 39 36 9 02 47 97 9 47 BYD360M6F 36 360 39 7 9 07 48 3 9 53 BYD365M6F 36 365 40 04 9 12 48 63 9 59 BYD370M6F 36 370 40 38 9 17 48...

Page 27: ...25P6F 18 125 15 86 7 89 20 69 8 48 BYD130P6F 18 130 16 30 7 98 20 99 8 56 BYD135P6F 18 135 16 74 8 07 21 29 8 64 BYD140P6F 18 140 17 20 8 16 21 59 8 72 BYD145P6F 18 145 17 59 8 25 21 89 8 80 BYD150P6F...

Page 28: ...39 04 9 8 BYD310M6K 30 310 33 06 9 39 39 14 9 87 BYD315M6K 30 315 33 26 9 48 39 23 9 94 BYD210P6K 27 210 25 74 8 16 32 37 8 73 BYD215P6K 27 215 26 06 8 25 32 68 8 81 BYD220P6K 27 220 26 38 8 34 32 99...

Page 29: ...74 45 52 9 23 BYD340PHT 36 340 38 51 8 83 45 73 9 28 BYD345PHT 36 345 38 68 8 92 45 94 9 33 BYD350PHT 36 350 38 86 9 01 46 15 9 38 BYD355PHT 36 355 39 03 9 10 46 36 9 44 BYD360PHT 36 360 39 21 9 19 46...

Page 30: ...3 8 74 45 52 9 23 BYD340PHL 36 340 38 51 8 83 45 73 9 28 BYD345PHL 36 345 38 68 8 92 45 94 9 33 BYD350PHL 36 350 38 86 9 01 46 15 9 38 BYD355PHL 36 355 39 03 9 10 46 36 9 44 BYD360PHL 36 360 39 21 9 1...

Reviews: