BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
6
INSTALLING THE OPERATOR
! ADVISORIES!
A.
THIS LINEAR ACTUATOR MUST ME MOUNTED SO THE PISTON
FULLY EXTENDS AND
FULLY RETRACTS
. WHEN FULLY RETRACTED THERE SHOULD BE
INCH PISTON LEFT
OUT OF THE FRONT.
B.
THIS LINEAR ACTUATOR HAS AN OFFSET BETWEEN THE FRONT AND REAR MOUNTING
BRACKET. THE FRONT BRACKET IS ABOUT 3/16+N OF AN INCH LOWER THAN THE REAR
BRACKET, REVIEW THE BRACKET ALIGNMENT DETAIL FOR THE OFFSET DIMENSION.
1.
SCRIBE THE CENTERLINE OF THE GATE LEAF ONTO THE GATEPOST.
2.
MEASURE FOR THE OFFSET DESCRIBED IN THE ADVISORY #B AND SCRIBE ANOTHER
LINE.
3.
CUT THE REAR MOUNTING BRACKET IN ACCORDANCE WITH THE DIMENSIONS
SPECIFIED ON THE MOUNTING GEOMETRY DETAIL.
4.
WELD THE REAR MOUNTING BRACKET TO THE GATE POST.
5.
DETERMINE THE “C” DIMENSION AND CUT THE FRONT MOUNTING BRACKET TO THE
PROPER LENGTH.
6.
EXTEND THE PISTON TO FULLY EXTENDED POSITION. THIS CAN BE ACHIEVED BY
TEMPORARILY CONNECTING THE CONTROL PANEL TO THE OPERATOR AND USING THE
MOTOR TO EXTEND THE PISTON, PRODUCING 9 7/8” OF PISTON. IT IS VERY IMPORTANT
WITH THE “600A” THAT THE PISTON
“BOTTOMS OUT IN BOTH DIRECTIONS”
.
7.
SCREW THE “I” BOLT INTO THE END OF THE PISTON
TO
OF THE LENGTH OF THE
THREADS.
8.
ATTACH THE OPERATOR TO THE FRONT MOUNTING BRACKET.
9.
WITH THE GATE IN THE FULL CLOSED POSITION, LEVEL THE OPERATOR AND SCRIBE
THE LOCATION FOR THE FRONT MOUNTING BRACKET.
10.
REMOVE THE FRONT MOUNTING BRACKET FROM THE FRONT OF THE GATE OPERATOR
AND WELD IT TO THE GATE LEAF AT THE SCRIBED LOCATION.
11.
ATTACH THE OPERATOR TO THE FRONT MOUNTING BRACKET.
12.
WITH THE OPERATOR IN MANUAL BYPASS, OIL FILLER CAP, SCREW ON, SWING THE
GATE OPEN AND CLOSED ABOUT 6 TIMES SLOWLY, TO PURGE THE AIR FROM THE
VALVE SYSTEM. SLOWLY OPEN THE FILLER CAP TO EXPEL ANY AIR IN THE OPERATOR.