Manufactured By
:
Byan Systems, Inc.
413 Linden
Lusk, WY 82225
(307)334-2865
(800)223-2926
Device Control System Power:
Connect outgoing power to the gate control system to TB2 using included wiring
(14/3 cord):
1.
115VAC Hot (Black)
2.
115VAC Neutral (White)
3.
Earth Ground (Green)
Commercial Power
Connect in-coming 115VAC single phase commercial power to TB1:
1.
115VAC Hot (Black)
2.
115VAC Neutral (White)
3.
Earth Ground (Green)
Device Control Functions
:
Connect supplied function control wiring harness (18/6 cord) to TB3
1.
Remote control device
2.
Motor 1 open contact.
3.
Motor 1 open common.
4.
Motor 1 cycle common.
5.
Motor 1 cycle contact.
6.
Motor 2 cycle contact.
7. Motor 2 cycle common.
8. Motor 2 open common.
9. Motor 2 open contact.
10. NOT USED
1 2 3 4 5 6 7 8 9 10
3 2 1
3 2 1
K1 four pole relay
R
elay
R
el
ay
re
la
y
Main chip
Dip switch
TB2
TB1
TB3