background image

NÜO Flux Manual

Installation

7

NÜO FLUX

Installation on built walls

1) Using a level, make a hole in the wall for the rear case measuring 82 x 82 mm and 52 mm deep. 

Do not forget to pass the reader cable through. 

Grout the hole with plaster and place the rear case in the hole.

82

82

52

Plaster

Place the magnet at the top. This magnet will work as a tamper. 

Recommended height for installation is between 1.2 and 1.5 m.

2) Remove the NÜO FLUX reader front glass 

panel using the suction cup supplied. Place 

the suction cup in a corner for ease of oper-

ation.

3) Pass the cable through the opening made 

and attach the reader to the rear case using 

the screws supplied as shown in the drawing. 

Finally, replace the front glass panel.

1. 

Installation on working surfaces:

The NÜO FLUX reader can be flush mounted in various environments. The various installation methods 

are described below, covering built walls, plasterboard walls, and integration into other equipment such as 

turnstiles or gates:

Summary of Contents for NUO FLUX

Page 1: ...Manual 41762 42039 NÜO FLUX ...

Page 2: ...2 ...

Page 3: ...oustic light display Communication encrypted with AES AND 3DES encryption algorithms IP65 protection Operating temperature from 20 C to 50 C for in door and outdoor installations References according to black and white model White 42039 Black 41762 REGULATIONS ISO IEC 14443 A and B AES128 NIST FIPS PUB 197 MIFARE Plus EAL4 Common Criteria certification NFC MIFARE emulation compliant EN 60950 1 200...

Page 4: ...ly 250 mA maximum ALARM 2 sound levels incorporated for granted access and denied access ILLUMINATION Automatically regulated according to environmental conditions Colours according to status Red White Terminal offline Degraded Red Pink Terminal in card enrolment mode Flashing blue Terminal in firmware update mode Blue Terminal on standby Green Access granted Red Access denied White Card writing o...

Page 5: ...E 92 x 92 x 57 mm height x width x depth EMBEDDED CASE DIMENSIONS 82 x 82 x 52 mm height x width x depth ACCESSORIES Embedded case Suction cup to remove front glass panel Bag with accessories Screws to fasten reader to the embedded case Screws washers and nuts for surface mounting 3 metres of piped cable with 4 wires 2 twisted pairs and a female con nector ...

Page 6: ...uilt in piped cable used to connect the reader has the following technical characteristics Gauge 0 22 mm Arrangement 2 twisted pairs Resistance 2 Ohms A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input out put readers or with 2 readers that are very close together TYPE OF WIRING AND WIRING DISTANCE WIRING SPECIFICATIONS DISTANCE BETWEEN READERS The wir...

Page 7: ...n is between 1 2 and 1 5 m 2 Remove the NÜO FLUX reader front glass panel using the suction cup supplied Place the suction cup in a corner for ease of oper ation 3 Pass the cable through the opening made and attach the reader to the rear case using the screws supplied as shown in the drawing Finally replace the front glass panel 1 Installation on working surfaces The NÜO FLUX reader can be flush m...

Page 8: ...case to the wall These tabs apply pressure against the wall as the screws are turned 82 82 Plasterboard Plasterboard Place the magnet at the top This magnet will work as a tamper Recommended height for installation is between 1 2 and 1 5 m 3 Remove the NÜO FLUX reader front glass panel using the suction cup supplied Place the suction cup in a corner for ease of oper ation 4 Pass the cable through ...

Page 9: ...the suction cup supplied Place the suction cup in a corner for ease of oper ation 78 80 78 80 3 Place the reader in the hole and insert the screws in the holes located in the corners of the reader 4 The equipment can be installed with the screws nuts and washers supplied or if tapped holes have been used then only the screws are required Once secure place the front glass panel to complete the inst...

Page 10: ...owed For more detailed information consult the equipment manuals referenced earlier READER WIRING Respect the specified input voltage Install the reader using voltage free power cables NÜO readers support an input voltage ranging from 11 to 28 VDC 24 VDC is recommended in order to avoid possible voltage drops These signals must be perfectly isolated in order to prevent damaging the equipment or in...

Page 11: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interferen...

Reviews: