background image

A

1

B

C

Spout

Base of Tap

Work Surface

White Plastic

Locating Washer

Lock Nut

Compression Nut

Blue Flexible Tube

Ferrule

Tube Insert

Star Washer

Black Rubber Washer

2

A

Piercing Screw

Cold Mains

Supply

Red Flexible

Tube

3

C

B

1. Selecting the Tap Location

 (cont)

(A) Line bottom of sink with newspaper to prevent metal shavings,

parts, or tools from falling down drain and damaging sink disposal

unit if fitted.

(B) If sink is porcelain-coated, place masking tape over are to be drilled to

prevent excess chipping of enamel. Use a cone-shaped grinding wheel to

grind away a 3/4-inch diameter circle of porcelain before drilling.

WARNING: 

Wear safety glasses to prevent eye injury.

(C) Mark hole with center punch. Use a 6mm drill bit for a pilot hole, then

using a 12mm diameter bit, drill a hole completely through the sink or

worktop. Smooth rough edges with a file.

2. Mounting the Tap

(A) The tap should be positioned on a work surface adjacent to a sink

where the spout can properly discharge water into the basin.

(B)  Using a pencil, mark the work surface to indicate the centre of the tap.
(C) Drill a 1/2” hole where marked on the work surface.
(D) Insert the black rubber washer into the base of the tap.
(E)  Insert the threaded section of the tap body into the 1/2” hole.
(F)  Assemble the washers and lock nut on the threaded section as over.
(G) Tighten the lock nut to prevent the tap moving. Do not over tighten.
(H) Ensure compression nut, ferrule and tub insert are positioned on the blue
    flexible tubes shown over.
(I)  Insert the open end of the blue flexible tube assembly into the base of the

threaded section of the tap.

(J) Tighten the compression nut to ensure a watertight seal.

Do not over tighten.

3. Installing the Saddle Valve

Before carrying out any installation TURN OFF THE WATER 
SUPPLY AT THE MAIN STOP COCK.

•  Place the saddle clamp on to the cold mains supply pipe to the kitchen

 

sink. Make sure that the 

saddle 

A is in place as shown in the diagram.

• Tighten the locking screw C to clamp the pipe securely.

• Turn the piercing screw B clockwise and fully home to puncture the pipe

.

Leave in this position until final assembly (see section 7) 

4. Mounting the Filter System

(A)

Select location under sink where filter is to be mounted.

NOTE:

 Allow 50 mm clearance below housing or 280mm below filter head

 to enable filter cartridge changes. 

CAUTION:

 Filter head should be mounted on stud or firm surface. The 

mounting bracket will support the weight of the filter and prevent the strain on 

the cold water line.

(B)

Filter head should be mounted in vertical position, use mounting bracket

as a template to mark screw locations. Mount filter head in marked

location using screws.

2

01767SR_ TPF Operating Instructions.indd   2

02/06/2014   16:42

To Detach Cartridge

R3

B

A

B

A

R4

To Attach Cartridge

5. Connecting the Saddle Valve & Tap Tube

to the Filter Head

The cartridge head tube fitting system is a push-fi t system where the tube 

securing mechanism is integrated into the cartridge head itself. 
First make sure the tube ends are clean. Just push the tube end squarely into 

the joint housing in the cartridge head, until it hits the shoulder (approximately 

10-15 mm) referring to the arrows on top of the housing to indicate flow

 

direction and that pipes are connected appropriately. (See image opposite)
Once the tube is in place, to confirm that the joint is secure, tug gently 

backwards on the tube. 
The tube should now be secure.
If for any reason you need to remove one of the tubes, press the blue 

compression ring in the corresponding cartridge head housing inwards. This

 

should free the tube and allow easy removal.

6.

 

Installing the  Cartridge

Hold cartridge from the bottom when installing or changing the cartridge. 

Use caution not to scrape knuckles on bracket when locking the cartridge into 

place. Line up the arrow on the cartridge with unlocked padlock on head. 

Insert cartridge and turn arrow to locked padlock. 

(See Diagram R4)

7.

 

Putting the Filter into Operation

•  Open the quarter turn tap fully to allow for continuous fl ow, then slowly

 

turn the piercing screw B anti-clockwise allowing water to enter the 

f

ilter

 

slowly and displace trapped air and loose particles.

• When the water runs clear, turn the piercing screw B anti-clockwise until

 

fully 

open and the water fl ows at maximum rate,

 (1.9 L/min).

• Allow water to fl ow through the system for around 15 minutes when fi rst

 

installed or when left unused for a prolonged period of time.

• Always fl ush for 10 seconds prior to use.
• Check for leaks before leaving installation. If it leaks, see Troubleshooting. 

R. Filter Cartridge Replacement

NOTE

: It is recommended that the cartridge be replaced every six months, or

when you notice a change in taste, odour, or fl ow of the water being fi ltered.
(1) Turn off the water supply to the fi lter and dispense water from drinking

water tap until water fl ow stops to relieve pressure.

(2) Place towel under the system to catch any water drips.
(3) (a) Turn arrow from locked to unlocked position.

(b) Remove cartridge.

(4) (a) Line up arrow with unlocked position on head and insert cartridge.

(b) Turn to locked position.

(5) Turn on water and check for leaks. If it leaks, see Troubleshooting.
(6) Flush water through drinking water tap for 5 minutes to remove

carbon fi nes. Check for leaks before leaving installation. If it leaks,

see Troubleshooting.

3

5

Inlet

Outlet

01767SR_ TPF Operating Instructions.indd   3

02/06/2014   16:42

Leave in this position until final assembly (see section 7)

saddle

(1.9 L/min).

Summary of Contents for TFPKIT

Page 1: ...0002 mg L 0 0002 mg L 0 00005 mg L 0 00005 mg L Avg Min Reduction 99 99 8 99 99 99 99 999 96 99 95 99 3 99 3 98 6 98 97 7 97 7 97 5 97 5 4 01767SR_ TPF Operating Instructions indd 4 02 06 2014 16 42 Performance Data Taste Fresh Protection Drinking Water System Installation and Operating Instructions Model TFPKIT Speci ications Pressure Range 30 72 psi 2 1 5 bar Temperature Range 40 100 F 4 4 37 7 ...

Page 2: ... in marked location using screws 2 01767SR_ TPF Operating Instructions indd 2 02 06 2014 16 42 To Detach Cartridge R3 B A B A R4 To Attach Cartridge 5 Connecting the Saddle Valve Tap Tube to the Filter Head The cartridge head tube fitting system is a push fit system where the tube securing mechanism is integrated into the cartridge head itself First make sure the tube ends are clean Just push the ...

Page 3: ... in marked location using screws 2 01767SR_ TPF Operating Instructions indd 2 02 06 2014 16 42 To Detach Cartridge R3 B A B A R4 To Attach Cartridge 5 Connecting the Saddle Valve Tap Tube to the Filter Head The cartridge head tube fitting system is a push fit system where the tube securing mechanism is integrated into the cartridge head itself First make sure the tube ends are clean Just push the ...

Page 4: ...0002 mg L 0 0002 mg L 0 00005 mg L 0 00005 mg L Avg Min Reduction 99 99 8 99 99 99 99 999 96 99 95 99 3 99 3 98 6 98 97 7 97 7 97 5 97 5 4 01767SR_ TPF Operating Instructions indd 4 02 06 2014 16 42 Performance Data Taste Fresh Protection Drinking Water System Installation and Operating Instructions Model TFPKIT Speci ications Pressure Range 30 72 psi 2 1 5 bar Temperature Range 40 100 F 4 4 37 7 ...

Reviews: