8
Technical data
Rondomat HVD
Unit
400
600
900
1200
1550
Max. flow velocity*
m³/t
10/15
18/21
25/30
32/39
41/50
Pressure drop at max. flow
velocity
bar
1,1 / 1,5
Min. flow velocity *
m³/t
0,08
0,35
0,35
3,0
3,0
Capacity at 1°dH
m³
1085
1680
2520
3290
4340
Capacity at 5°dH
m³
217
336
504
658
868
Capacity at 15°dH
m³
72
108
168
220
289
Capacity at 20°dH
m³
54
84
126
165
217
Salt consumption pr.
regeneration
kg.
31
48
72
94
124
Time pr. regeneration
min.
50
55
60
65
70
Max. water temperature
°C
35
Water pressure max.
bar
10
Pipe connection
DN
50
100
Water connection
DN
40
Height [A]
mm
2520
2600
2800
2750
2800
Width [B]
mm
2800
3000
3120
3550
4000
Depth [C]
mm
1400
1500
1600
1800
1900
Height Salt container [D]
mm
1120
Diameter salt container [E]
mm
1350
Capacity salt container
litre
1000
Water consumption pr.
Regeneration*
m³
0,55
0,75
1,05
1,48
2,0
Product number:
422162320
422162470
422162670
422162920
422163220
Product number; hardness test
701995010
Product number; Salt alarm
401528200
*At 15 °C, 3,0 bar before the unit and new clean ion exchange resin. At continually operation should the capacity on
some models be reduced, depending on the condition of the raw water. * Brine is not included in the water consumption