Rondomat HVD 400-1550
Softening Unit
Installation and operation manual EN
659997220/
EN
/4
Page 1: ...Rondomat HVD 400 1550 Softening Unit Installation and operation manual EN 659997220 EN 4...
Page 2: ...u 8 5 1 2 Functions in the menu 8 5 2 Operation 9 5 2 1 Information in operation 9 5 2 2 Functions in Operation 9 5 3 Mimic 10 5 3 1 Information in Mimic 10 5 4 Auto Man 10 5 4 1 Information in Auto M...
Page 3: ...ounters 13 5 11 Language 14 5 11 1 Information in Language 14 5 11 2 Functions in Language 14 5 12 Time and date 14 5 12 1 Information in time date 14 5 12 2 Functions in time date 14 5 13 Password 15...
Page 4: ...ly low salt and water consumption during operation due to the built in conductivity measurement The system is controlled by a PLC so it is always possible to change the operating parameters The PLC is...
Page 5: ...t rinse which displaces the salt solution through the ion exchanger The regeneration ends with a second flush that is controlled by the conductivity of the wastewater After 2nd flush the filter is aut...
Page 6: ...yed This valve is for filling the last part of the Strong cation and the inert resin Firstly the top pip have to be removed so the water can over float when the resin is filled into the container At t...
Page 7: ...EN 7 c Fill the salt container with water by opening the valve for incoming water Let the valve stay open for operation Figure 2 Salt Container Keep undissolved salt out of the tube...
Page 8: ...Press Alarm settings Press Reg settings On the operating screen it is possible to start and stop the operation and regeneration On the mimic screen is indicated status of operation and valve pump On t...
Page 9: ...ed Reg Timer Regeneration time in the activated step 5 2 2 Functions in Operation Press OFF ON Press Start Reg Press Step Reg Changes to alarm history where all alarm occurrences are stamped with time...
Page 10: ...mps Pumps Black OFF White ON Valves Black closed White open 5 4 Auto Man 5 4 1 Information in Auto Manuel This function visualize the manual interference AUT MAN 5 4 2 Functions in Auto Manuel Selecte...
Page 11: ...pr m Select options 5 6 Alarm settings 5 6 1 Information in Alarm Settings Delay of various alarms and set points for the conductivity in the second flush 5 6 2 Functions in Alarm Settings Setting di...
Page 12: ...the hardness of the raw water It s possible change between dH fH and ppm CaCO3 The capacity in the Ion exchange resin preconfigured to 2 8 m3 Password See chapter 5 13 5 8 Alarm 5 8 1 Information in A...
Page 13: ...Functions in Alarm Log By pressing the START button can the UP DOWN buttons be used to go through the registered alarms CLEAR ALL Deletes the log Password Se afsnit5 13 5 10 Counters 5 10 1 Informatio...
Page 14: ...options 5 11 2 Functions in Language To select a language Press the preferred language 5 12 Time and date 5 12 1 Information in time date Date and time 5 12 2 Functions in time date Date and time can...
Page 15: ...We recommend to use salt tablets or granulated vacuum salt if using a Saturator The plant is designed for a brine solution of 300g liter of water Frequently empty and rinse the salt container The qua...
Page 16: ...After a prolonged period of closure take the following precautions Drain the filter containers for liquid and perform a double regeneration on the ion exchanger BWT Denmark A S offers various types of...
Page 17: ...r 10 Pipe connection DN 50 100 Water connection DN 40 Height A mm 2520 2600 2800 2750 2800 Width B mm 2800 3000 3120 3550 4000 Depth C mm 1400 1500 1600 1800 1900 Height Salt container D mm 1120 Diame...
Page 18: ...EN 18 9 Spare part drawing...
Page 19: ...6 1 Once a year 12 Pressure gauge for reduc valve 200781108 13 Dist syst T 14 36 flange top 350244100 1 14 Dist syst T 24 flange bottom 350244108 1 15 Salt hose 5 8 401528050 1 16 Drain elbow 40537873...
Page 20: ...EN 20 11 P I Diagram...
Page 21: ...45 43 600 900 BWT BWT dk www BWT dk Here by declares that HVD 400 600 900 1200 1550 is in conformity with the provisions of the Machinery Directive Directive 2006 42 EC is in conformity with the provi...
Page 22: ...__________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _____...
Page 23: ...__________________________________________________________ _______________________________________________________________________________________ _____________________________________________________...
Page 24: ...EN 24 Bwt com...