10
Connections
Hoses must be cut with a sharp blade to ensure that it stays round, do not use a tool that deforms the hose
in any way.
Valve block
The integrated valve block contains four valves, a brine pump and a pressure switch. The valve block distributes
water and brine through the machine. The brine pump is used for both Neuthox® production and softener
regeneration. The valves are marked individually on the block.
AV02, Cell inlet valve (NC)
AV04, Drain valve (NO)
AV07, 3/2-way valve (directs flow to production process when inactive)
Switches water flow between production- and regeneration process
AV08, Tank fil valve (NC)