BWT Bewades LC Installation And Operating Manual Download Page 4

DE

DE

5

4

Safety Instructions

1�1 

General safety instructions

The  product  was  manufactured  according  to  all 

recognised regulations and technical standards and 

was in compliance with the relevant legal require

-

ments when it was put into circulation. 
Nevertheless, it can pose a risk of personal injury 

or  property  damage  if  you  do  not  observe  this 

chapter and the safety instructions throughout this 

documentation.

 

● Read this documentation thoroughly and in full 

before working with the product.

 

● Retain the documentation in such a way that it is 

accessible to all users at all times.

 

● Always  hand  over  the  product  to  third  parties 

together with the full documentation.

 

● Follow  all  of  the  instructions  in  relation  to  the 

proper handling of the product.

 

● If you detect damage to the product or the mains 

supply,  stop  its  operation  and  notify  a  service 

technician immediately.

 

● Use only accessories, spare parts and consuma

-

ble materials that have been approved by BWT.

 

● Adhere to the environmental and operating con

-

ditions specified in the “Technical data” chapter.

 

● Use your personal protective equipment. It en

-

sures your safety and protects you from injury.

 

● Only perform tasks that are described in these 

operating instructions or if you have been trained 

to do so by BWT.

 

Perform all tasks in compliance with all applicable 

standards and provisions.

 

● Instruct the operator in the function and operation 

of the product.

 

Instruct the operator in the maintenance of the 

product.

 

● Instruct the operator in relation to potential dan

-

gers that may arise while operating the product. 

1�2 

Scope of the documentation

This  documentation  applies  exclusively  to  the 

product the production number of which is listed in 

chapter 12 “Technical Data”. 
This  documentation  is  intended  for  operators, 

installers without training from BWT, installers with 

training from BWT (e.g. drinking water specialists), 

and BWT service technicians.
This documentation contains important information 

for fitting the product safely and properly, starting 

up, operating, using, maintaining, and disassem

-

bling the product, and for correcting simple faults 

independently.
Read this documentation in full before working with 

the product. Pay particular attention to the chapter 

“Safety Instructions”.

1�3 

Personnel qualifications

The installation work described in these instructions 

requires basic knowledge of mechanics, hydraulics 

and electrical systems as well as knowledge of the 

corresponding specialist terms.
To ensure that the device is installed safely, this work 

must be performed only by a qualified specialist or 

a trained person under the guidance of a qualified 

specialist.
A qualified specialist is anyone who can assess the 

work assigned to him or her, identify potential risks, 

and take suitable safety measures thanks to his or 

her specialist training, knowledge and experience 

as well as his or her knowledge of the applicable 

regulations. A qualified specialist must comply with 

the applicable specialist regulations.
An  instructed  person  is  anyone  who  has  been 

instructed and, if necessary, trained by a qualified 

specialist in the transferred tasks and the potential 

risks  presented  by  improper  behaviour  and  who 

has been educated about the necessary protective 

equipment and measures. 

1�4 

Transport and installation

To avoid damage during transport to the installation 

location, do not remove the BWT product from the 

packaging until you have reached the relevant lo

-

cation. Then dispose of the packaging in the correct 

manner. Check that the delivery is complete.
If there is a risk of frost, drain all components that 

convey water.
Lift or transport the product or its components only 

from the designated suspension eyes or attachment 

points, if present.
The product must be installed or mounted on a suf

-

ficiently strong and level horizontal surface and must 

be adequately secured against falling or tipping.

Summary of Contents for Bewades LC

Page 1: ...Subject to change 1 511088 14277 2022 03 BWT Wassertechnik GmbH Printed in Germany UV disinfection unit Bewades LC Installation and operating manual EN...

Page 2: ...d and approved in German If there are any discrepancies between the German edition of the manual and editions in other languages the information in the German document should be given preference In th...

Page 3: ...esign of UV units 9 5 Installation conditions 9 5 1 General 9 5 2 Installation site and environment 9 5 3 Feed water 9 5 4 Installation 9 5 5 Operation 9 6 Installation 10 6 1 Installation diagram 10...

Page 4: ...BWT e g drinking water specialists and BWT service technicians This documentation contains important information for fitting the product safely and properly starting up operating using maintaining and...

Page 5: ...1 6 How warnings are displayed In this document warnings precede any sequence of actions that could cause harm to persons or da mage to property All hazard prevention measures must be followed Warnin...

Page 6: ...k 5 is in place If this is not the case the emitter protection tubeisforcedupwardsbythewaterpressure WARNING Ultraviolet rays Burn hazard for eyes and skin Only start up the unit with the protective c...

Page 7: ...erial and a spanner for the threaded joint Bewades 70W70 08 LC 200W200 11LC and 400W200 17LC Radiation chamber with built in agitators in stain less steel Switchbox with ballast for emitter 1 Emitter...

Page 8: ...reseeable misuse Operating the system with parameters other than those specified in this documentation and in sec tion 3 1 Non compliance with the operating and environ mental conditions specified in...

Page 9: ...above the unit to facili tate emitter replacement see dimensions If the cable length between the UV emitters and the ballast unit is longer than 6 m please consult our technical department The emissio...

Page 10: ...ssurize unit unless the upper emitter protection tube lock 5 is in place If this is not the case the emitter protection tubeisforcedupwardsbythewaterpressure WARNING Ultraviolet rays Burn hazard for e...

Page 11: ...chamber Rotate the O ring 2 from the bag of accessories over the top of the emitter protection tube and secure the threaded joint 3 While doing so pull the emitter protection tube up approx 1mm see d...

Page 12: ...tight and tighten further using the special spanner from the bag of accessories if necessary a small gap remains between the tensioning screw and the cover of the UV unit Insert the emitter 6 careful...

Page 13: ...in place If this is not the case the emitter protection tubeisforcedupwardsbythewaterpressure WARNING Ultraviolet rays Burn hazard for eyes and skin Only start up the unit with the protective cap 8 on...

Page 14: ...e emitter protection tube with a soft cloth If required an acid e g citric acid or a solvent e g alcohol can be used Insert the emitter protection tube 1 follow the lower guide in the radiation chambe...

Page 15: ...nd connect with the plug 7 of the blue protective cap 8 Attach the blue protective cap 8 and secure it with 2 stud screws Open shut off valves up and downstream of the unit The unit is now ready for u...

Page 16: ...The prerequisite for proper function and the warran ty are a regular inspection by the operator every 2 months and routine maintenance EN 806 5 by the BWT after sales service staff or an installer au...

Page 17: ...g every 8000 h Emitter casing tube every 8000 h Support ring every 8000 h Starter only 80 W emitter every 10000 starts Functional tests Check connection line and housing for damage Check the wiring Ch...

Page 18: ...missioning and dis posal 12 1 Decommissioning The product may only be shut down and dismantled by qualified specialists Observe all applicable safety regulations when dismantling the system 12 2 Dispo...

Page 19: ...number see the label on the title page of this manual and the type plate of the product Bewades Type 100W100 11LC 200W200 11 LC 400W200 17 LC Nominal connection width DN 50 2 IG 50 2 IG 80 Volume flo...

Page 20: ...r emitter replacement Bewades 80W80 11 LC B A D E F clearance for emitter replacement B A D E Bewades 70W70 08 LC G P K Bewades A B C D E F G K P 70W70 08 LC 76 1 68 316 410 380 400 200 120 80W80 11 L...

Page 21: ...learance for emitter replacement B A D E F clearance for emitter replacement C Bewades 200W200 11 LC B A C D E G P K Bewades A B C D E F G K P 100W100 11 LC 128 114 1096 1310 1300 400 200 120 200W200...

Page 22: ...he treatment of foodstuffs with electrons gamma rays and x rays neutrons or ultraviolet rays Lebensmittelbestrahlungs verordnung German Food and Commodities Law Lebens mittel und Bedarfsgegenst ndeges...

Page 23: ...C Baureihe Bewades LC series Bewades LS s rie ist entwickelt konstruiert und gefertigt in bereinstimmung mit den oben genannten Richtlinien in alleiniger Verantwortung von is developed designed and pr...

Page 24: ...GmbH Walter Simmer Stra e 4 A 5310 Mondsee Phone 43 6232 5011 0 E Mail office bwt at BWT Wassertechnik GmbH Industriestra e 7 D 69198 Schriesheim Phone 49 6203 73 0 E Mail bwt bwt de Further informat...