3

3

AUS

For the backwashing process, the waste water con-
nection is opened by turning the turning knob (5) 
and the backwashing element is also turned. The 
particles on the filter cloth are removed by suction 
from the suction-ring backwashing system and then 
washed out. 

4  Installation conditions

The unit must be installed by a licenced tradesper-
son to AS/NZS 3500.

A connection must be available for draining the flus-
hing water.

The filter installation must be protected against 
freezing conditions, solvent vapours, fuel oil, che-
micals of all kinds, UV radiation and heat sources 
above 40 °C.

If the unit has been dropped or damaged, plastic 
parts must be replaced even if there is no visible 
damage. A cover is recommended where the filter 
is installed in direct sunlight.

The unit should be installed to allow clear access 
for removal.

Observe the local installation regulations, gener-
al guidelines, general hygiene regulations and the 
technical specifications.

A connection to the sewage system (discharge) of 
min. DN 40 should be available.

Attention: The installation site must be protect-
ed against frost and must ensure the protection of 
the filter against e.g. solvent vapours, fuel oil, lees, 
chemicals of any kind, UV radiation and heat sourc-
es above 40 °C.

Attention: Keep the plastic parts free from grease, 
solvents and acidic as well as basic detergents. The 
plastic parts must be replaced even if there is no vis-
ible damage after severe concussions and shocks 
e.g. due to the use of unsuitable tools or if dropped 
on stone floors etc (danger of bursting). Avoid ex-
treme pressure impact.

Σ

m

3

 0 0 0

> 20  mm

Summary of Contents for Avanti RF Series

Page 1: ...nt filter complete with dual check valve backflow prevention device Installation and operating manual AUS Suitability Suitable for domestic and commer cial installations to remove sedi ment and improv...

Page 2: ...umbing fixtures and fittings from mal functioning and against damage caused by foreign particles such as rust swarf and sand The filters are not intended for use with chemically treated circulating wa...

Page 3: ...cover is recommended where the filter is installed in direct sunlight The unit should be installed to allow clear access for removal Observe the local installation regulations gener al guidelines gene...

Page 4: ...must be in stalled at a minimum distance of 20 mm above the highest possible waste water level free discharge 6 Startup Check the filter and the flushing water pipe for prop er installation The stop v...

Page 5: ...pipe is not connected to the waste water drain Backwashing Open the turning knob 5 counter clockwise until you can hear water running out and then close it again Check whether the filter is correctly...

Page 6: ...ng knob repeat backwash sev eral times If the fault cannot be rectified using these notes please contact your local Reece branch Flow rate Avanti RF Type 1 Flow rate Avanti RF Type 2 6 7 26 7 43 3 55...

Page 7: ...0 15 5 Filter screen m 90 110 Nominal pressure PN bar 16 Water temperature C 5 30 Ambient temperature max C 5 40 Overall length without fitting A mm 100 140 Overall length with fitting B mm 205 327 To...

Page 8: ...Due to limitations in the printing process the colours in this brochure are a guide only The manufacturer distributor reserves the right to vary specifications or delete models from their range witho...

Reviews: