EN
43
7 .4 .1 Resetting the litres per day counter
f
Press the circle button.
The product is set to
PAUSE
.
f
Press the checkmark button.
The prompt
RESET ?
appears on the display.
f
Press the checkmark button again.
The litres per day counter is set to
ZERO
LITRES
.
7 .4 .2
Setting the switch-on and switch-off
point for pressure production
NOTE
Membrane cartridge wear!
The membrane cartridges are worn down quickly if the
operating times are too short (frequent starting and
stopping)
►
When setting the switch-on and switch-off point for pres-
sure production, a difference of at least 1 bar must be main-
tained.
The integrated pump in the product produces the
outlet water pressure required to fill the system.
When the preset system pressure is reached, pres-
sure production stops. This pressure value is refer-
red to as the switch-off point (
STOP
).
If the system pressure falls to a preset value, the
pump begins to produce the outlet water pressure
again. This pressure value is referred to as the
switch-on point (
START
).
The switch-off point (
STOP
) and switch-on point
(
START
) for pressure production are set as follows:
f
Press the circle button.
The product is set to
PAUSE
.
f
Press and hold one of the two arrow buttons
for three seconds.
f
Press the checkmark button to switch be
-
tween the switch-off point (
STOP
) and switch-
on point (
START
).
f
Press the arrow buttons to increase or lower
the point selected earlier.
8
Additional functions in the
BWT RO systems app
To install the
BWT RO systems app
,
you require a scanner app on your
mobile device. Some of the scanner
apps available on the market are not
compatible.
The
BWT RO systems app
displays all the values
from the product display. You can set limit values
and reset the litres per day counter in the technici-
an menu in the
BWT RO systems app
.
The
BWT RO systems app
is
connected to the
product via Bluetooth.