10
EN
1 Scope of delivery
For professional installation of the filter system the following parts are required:
Filter cartridge (1) with hygienic cap and male thread for screwing into the filter head (2).
Filter head (2) with female thread for mounting the filter cartridge (1), suitable for all filter
cartridge sizes with installation label. An Aquastop and two non return valves (inlet and outlet)
are installed in the filter head.
Bracket (3) for mounting the filter cartridge.
The filter cartridge has to be ordered separately from the filter head. The bracket is included in
the scope of delivery of the filter head.
2 Technical Data
2.1 Dimensions und weights
TC200
Total height without bracket, max.
A
mm
(inch)
360
(14
3
/
16
)
Total height with bracket
B
mm
(inch)
385
(15
3
/
16
)
Connection height
C
mm
(inch)
306
(12
1
/
16
)
Distance from floor
D
mm
(inch)
65
(2
9
/
16
)
Installation length
E
mm
(inch)
125
(4
15
/
16
)
Filter cartridge Ø
F
mm
(inch)
88
(3
7
/
16
)
Weight of dry filter cartridge, approx.
kg
(lb)
0.8
(1.8)
Weight of wet filter cartridge, approx.
kg
(lb)
1.3
(2.9)
2.2 Operating conditions
TC200
Connection thread
(intake/outlet)
3
/
8
“
(BSP male)
Nominal flow
L/h
(US gal/h)
180
(48)
Working pressure range
bar
(psi)
2 – 8
(29 - 116)
Intake water pressure
bar
(psi)
> 1.2
(> 17.4)
Pressure loss at 30 L/h
(8 US gallons/h)
¹
bar
(psi)
0.10
(1.5)
Pressure loss at 60 L/h
(16 US gallons/h)
¹
bar
(psi)
0.15
(2.2)
Pressure loss at 180 L/h
(48 US gallons/h)
¹
bar
(psi)
0.60
(8.7)
Water temperature, min.–max.
°C
(°F)
+4 to +30
(+39 to +86)
Ambient temperature, min.–max.
°C
(°F)
+4 to +40
(+39 to +104)
Ambient temperature during transportation/storage, min.–max.
°C
(°F)
-20 to +40
(-4 to +104)
Typical capacity
L
(US gal)
8000
(2113)
Operating position
L
(US gal)
vertical
Minimum flushing volume
L
(US gal)
3
(0.8)
Sum iron and manganese content
mg/L
(ppm)
< 0.2
(<0.2)
Free chlorine
mg/L
(ppm)
< 0.5
(<0.5)
Retention of bacteria
%
(log range)
99.9999
(log 6)
Width of pores of ultrafiltration membrane
µm
0.02
¹with a 1.5 m (59.06 inch) hose DN8 fitted to both the intake and outlet.
3 Usage and design
3.1 Assigned use
This BWT filter cartridge …
is only to be used for optimising cold water fulfilling the legal requirements for drinking water.
protects against bacteria, cryptosporidium, giardia, protozoa as well as microplastics and
provides hygienically perfect water for cold water dispensers and ice cube machines.
is only to be used with water without added carbonic acid.
1
2
FWC_NeuesDesign_blau.indd 10
05.10.2018 09:01:24