![BWT AQA blue Installation And Operating Instructions Manual Download Page 4](http://html1.mh-extra.com/html/bwt/aqa-blue/aqa-blue_installation-and-operating-instructions-manual_2836662004.webp)
Guarantee
In the event of a fault during the guarantee
period, please contact your contracting
partner.
Operator Duties
» You have purchased a long-lasting and
service-friendly product. However, every
technical appliance requires regular
service work to maintain correct
functioning.
» Sensor unit: check daily for leaks.
» Battery: If the battery must be replaced,
this will be indicated in the display.
Connection thread (IN/OUT):
3/8” nut x 3/8”
connection thread
Intake pressure (min/max):
2 - 8 bar
Flow capacity:
0.8 - 15 l/min
Flow rate deviations:
+/- 5 %
Water temperature (min/max): +4 - +30 °C
Ambient temperature (min/max): +4 - +40 °C
Dimensions (L x W x H):
80 x 47 x 30 mm
Installation position:
horizontal
Technical Data:
EN
4
Summary of Contents for AQA blue
Page 1: ...AQA Monitor FILTER CAPACITY CONTROL UNIT EN Installation and operating instructions...
Page 7: ...c EN Install sensor unit flow rate F UP 3 1 4 3 2 4 7...
Page 11: ...9 8 365 day 180 day WITH UF TECHNOLOGY 365 DAYS 180 DAYS ltr 1oo0o 11...
Page 13: ...C Function counting unit 0l oooo 4 SEC A A Back to 2 a page 9 B A 13...
Page 14: ...AA INSTALLATION 14...