background image

AIR-EAGLE

®

 

XLT PLUS 

900MHz RF Transceiver 

MODEL 461-40800-DC 

 
 

APPROVALS 

 

United States (FCC) 

MCQ-XBPSX 

Canada (IC) 

1846A-XBPSX 

 
 

GENERAL OPERATION 

 

Contact closures on inputs 1 thru 8 in the control transceiver transmit 
to activate relays #1 thru #8 in the remote transceiver. Inputs from the 
remote equipment provide closures to remote transceiver that transmit 
to energize relays 1 thru 8 in the control transceiver.   

 

INPUT 

ACTIVATED 

ACTION 

"1" 

Transmits channel 1 command to remote unit 

"2" 

Transmits channel 2 command to remote unit 

"3" 

Transmits channel 3 command to remote unit 

"4" 

Transmits channel 4 command to remote unit 

“5” 

Transmits channel 5 command to remote unit 

“6” 

Transmits channel 6 command to remote unit 

“7” 

Transmits channel 7 command to remote unit 

“8” 

Transmits channel 8 command to remote unit 

INPUT CODE 

RECEIVED 

ACTION 

"1" 

Relay #1 energizes, maintained momentary 

"2" 

Relay #2 energizes, maintained momentary 

"3" 

Relay #3 energizes, maintained momentary 

"4" 

Relay #4 energizes, maintained momentary 

“5” 

Relay #5 energizes, maintained momentary 

“6” 

Relay #6 energizes, maintained momentary 

“7” 

Relay #7 energizes, maintained momentary 

“8” 

Relay #8 energizes, maintained momentary 

 

SPECIFICATIONS 

 

DC Input 

9 - 36 VDC 10 W 

Fuse Protected 

2 amp 

Frequency 

900MHz Spread Spectrum 

Relay Contacts 

SPDT 5 amp @ up to 120VAC or 30VDC per 
channel 

Transmitter Data 

Eight Dry Contact Inputs 

RF Output Power 

1W 

Transceiver Range 

Up to 1 Mile with Rubber Duck Antenna / Up 
to 10 Miles with External Antenna 

Note:  Max range figures are estimates, based on free-air terrain with limited sources of 
interference. Actual range will vary based on transmitting power, orientation of transmitter 
and receiver, height of transmitting antenna, height of receiving antenna, weather 
conditions, interference sources in the area, and terrain between receiver and transmitter, 
including, but not limited to, indoor and outdoor structures such as walls, metal objects, 
trees, buildings, hills, and mountains.

 

RF Networks 

Eight Independent Network Frequencies 

Enclosure 

Hinged fiberglass with window / NEMA 3, 
3R, 4,12, 13 

Operating Temp 

-40

o

 F to +185

o

 F 

 

RELAY & FREQUENCY SET-UP 

 

This unit is shipped from the factory with the SEL1 switches in the open 
positions. All eight relays will operate in a maintained momentary manor, 
and unit is receiving commands on frequency one.  If you wish to change 
these default settings, follow the instructions on the table below. 

 

1)  Remove power from unit 

2)  Remove top cover. 

3)  Select desired relay operation and/or network frequency using table 

below. 

4)  Reattach cover and apply power. 

5)  Programming is now complete.  

RELAY CONFIGURATION 

SEL1 

SWITCH 

NUMBER 

OPEN 

CLOSED 

SW1 

Relays #1 thru #8 maintained 
momentary 

(default)

 

Relays #1 thru #8 
toggle/latch  

Maintained Momentary

 

– Relay mimics button or input – when 

depressed or closed, relay will be energized; when released, relay de-
energizes 
 

Toggle Latch

 

– Relay changes (and holds) its state each time the 

corresponding button or input is depressed or closed momentarily 

SW2-4 

Not used on this model 

FREQUENCY SET-UP 

SEL1 

Network 

Frequency 

SW5 

SW6 

SW7 

 

(SW5-7) 

(default)

 

OPEN 

OPEN 

OPEN 

CLOSED  

OPEN 

OPEN 

OPEN 

CLOSED 

OPEN 

CLOSED  

CLOSED 

OPEN 

OPEN 

OPEN 

CLOSED 

CLOSED 

OPEN 

CLOSED 

OPEN 

CLOSED 

CLOSED 

CLOSED 

CLOSED 

CLOSED 

 

ACCESSORIES

 

 

Standard Antenna (Included): 

900MHz TNC “Rubber Duck” Antenna  

49-1103 

Mobile/Base Antennas 

–  

Used to help achieve max range in both non line of sight and line of 

sight applications. - Contact BWI Eagle for recommendations 

900MHz Thru-Hole Mount Mobile Antenna 

49-2101 

900MHz Magnet Mount Mobile Antenna 

49-2102 

900MHz Omni Directional Base Antenna  

49-3101 

900MHz Yagi Directional Base Antenna 

49-3102 

High Quality Coax Cables 

– 

Used to connect external high gain antennas to control unit 

Flex Coax Cable w/Connectors 

– Available in 

5’,15’,25’,30’,40’,60’,80’,100’ Lengths 

49-4000-XX          
(XX = # of Feet) 

Bulkhead Extensions 

– 

Used to provide an external antenna connection when mounting 
control unit inside another enclosure 

TNC Male to TNC Bulkhead Cable Assembly  
- Av

ailable in 2’, 4’, 7’ Lengths 

49-5004-X-ISO 
(X = # of Feet) 

 

DOCUMENT DATE:  07/23/2021  /  PRODUCT REV. 3 

 