background image

PRODUCT INFORMATION 

BULLETIN 

 

 

 

105 Bonnie Drive 
Butler, PA 16002 
724-283-4681 
724-283-5939 (fax) 
www.bwieagle.com

 

 
 
 
 

 

 

 

AIR-EAGLE

®

 

XLT PLUS 

900MHz RF Transceiver 

MODEL 461-40800-DC 

 

DESCRIPTION

 

 

The A

IR

-E

AGLE 

XLT

 

P

LUS 

RF

 

T

RANSCEIVER 

provides two-way wireless 

control of electronic equipment and apparatus at distances up to 1 mile 
away (longer ranges can be achieved with external antennas). This 
model comes equipped with eight dry contact inputs and eight relay 
outputs. This allows the user to not only transmit information out, but 
receive a confirming signal back that the operation was performed A 
terminal strip has been provided for interfacing with external dry 
contact inputs as well as dry contact relay outputs. The Air-Eagle XLT 
TRX is user-programmable for up eight network frequencies to allow 
multiple systems to operate simultaneously in the same area. 

 

INSTALLATION 

 

DISCONNECT DC Power from all equipment before installation. 
 
1. 

Mount the A

IR

-E

AGLE 

XLT PLUS R

ECEIVER

 in a convenient location.  

2. 

Install input and output wiring to terminal strip. 

3. 

Install antenna to connector located on the right side on the 
enclosure.  

4. 

Connect supplied power input cable to your external power source. 

 

DIMENSIONS 

 

 

 

 
 

TERMINAL STRIP WIRING 

 

RELAY OUTPUTS 

N/O Relay #1 

10  N/O Relay #4 

19  N/O Relay #7 

C Relay #1 

11  C Relay #4 

20  C Relay #7 

N/C Relay #1 

12  N/C Relay #4 

21  N/C Relay #7 

N/O Relay #2 

13  N/O Relay #5 

22  N/O Relay #8 

C Relay #2 

14  C Relay #5 

23  C Relay #8 

N/C Relay #2 

15  N/C Relay #5 

24  N/C Relay #8 

N/O Relay #3 

16  N/O Relay #6 

 

C Relay #3 

17  C Relay #6 

N/C Relay #3 

18  N/C Relay #6 

CONTACT INPUTS 

Common Input 1 

10  Input 5 

 

Input 1 

11  Common Input 6 

Common Input 2 

12  Input 6 

Input 2 

13  Common Input 7 

Common Input 3 

14  Input 7 

Input 3 

15  Common Input 8 

Common Input 4 

16  Input 8 

Input 4 

17  Not Used 

Common Input 5 

18  Not Used 

DC INPUT 

Terminal #1 

(-) 9-36VDC Input 

Terminal #2 

(+) 9-36VDC Input 

 