BWI Eagle AIR-EAGLE XLT PLUS 461-20800-DC Product Information Bulletin Download Page 2

AIR-EAGLE

®

 

XLT PLUS 

900MHz RF Receiver 

MODEL 461-20800-DC 

 

RELAY & FREQUENCY SET-UP 

 

This unit is shipped from the factory with the SEL1 switches in the open 
positions. All eight relays will operate in a maintained momentary manor, 
and unit is receiving commands on frequency one.  If you wish to change 
these default settings, follow the instructions on the table below. 

 

1)  Remove power from unit 

2)  Remove top cover. 

3)  Select desired relay operation and/or network frequency using table 

below. 

4)  Reattach cover and apply power. 

5)  Programming is now complete.  

RELAY CONFIGURATION 

SEL1 

SWITCH 

NUMBER 

OPEN 

CLOSED 

SW1 

Relays #1 thru #8 maintained 
momentary 

(default)

 

Relays #1 thru #8 
toggle/latch  

SW2 

Not used on this model 

Maintained Momentary

 

– Relay mimics button or input – when 

depressed or closed, relay will be energized; when released, relay de-
energizes 

 

Toggle Latch

 

– Relay changes (and holds) its state each time the 

corresponding button or input is depressed or closed.  

SW3 

Vibrating Feedback OFF 

(default)

 

Vibrating Feedback ON 

SW4 

Not used on this model 

FREQUENCY SET-UP 

SEL1 

(SW5-7) 

Network 

Frequency 

SW5 

SW6 

SW7 

(default)

 

OPEN 

OPEN 

OPEN 

CLOSED  

OPEN 

OPEN 

OPEN 

CLOSED 

OPEN 

CLOSED  

CLOSED 

OPEN 

OPEN 

OPEN 

CLOSED 

CLOSED 

OPEN 

CLOSED 

OPEN 

CLOSED 

CLOSED 

CLOSED 

CLOSED 

CLOSED 

 

 

GENERAL OPERATION 

 

Relays #1 thru #8 energize or de-energize based on specific 
commands from a handheld or contact input transmitter.  
 

BUTTON OR 

INPUT 

ACTIVATED 

RELAY OPERATION 

"1" 

Relay #1 energizes, maintained momentary 

"2" 

Relay #2 energizes, maintained momentary

 

"3" 

Relay #3 energizes, maintained momentary

 

"4" 

Relay #4 energizes, maintained momentary

 

“5” 

Relay #5 energizes, maintained momentary

 

“6” 

Relay #6 energizes, maintained momentary

 

“7” 

Relay #7 energizes, maintained momentary

 

“8” 

Relay #8 energizes, maintained momentary

 

 

DIMENSIONS 

 

 

 

 

 

APPROVALS 

 

United States (FCC) 

OUR-9XTEND 

Canada (IC) 

4214A-9XTEND 

 

SPECIFICATIONS 

 

DC Input 

9 - 36 VDC @ 10 Watts 

Fuse Protected 

2 amp 

Relay Contacts  

SPDT 5 amp @ 120VAC or 30VDC 

Receiver Range  

Up to 1 Mile with Rubber Duck Antenna / Up 
to 10 Miles with External Antenna 

Note:  Max range figures are estimates, based on free-air terrain with limited sources of 
interference. Actual range will vary based on transmitting power, orientation of transmitter and 
receiver, height of transmitting antenna, height of receiving antenna, weather conditions, 
interference sources in the area, and terrain between receiver and transmitter, including, but not 
limited to, indoor and outdoor structures such as walls, metal objects, trees, buildings, hills, and 
mountains

 

Receiver Frequency 

900 MHz Spread Spectrum 

RF Networks 

Eight Independent Network Frequencies 

Enclosure 

Hinged fiberglass with window / NEMA 3, 
3R, 4, 12, 13 

Operating Temp 

-40

o

 F to +185

o

 F 

 
 
 