PRODUCT INFORMATION
BULLETIN
238 Pillow Street
Butler, PA 16001
724-283-4681
724-283-5939 (fax)
www.bwieagle.com
AIR-EAGLE
®
SR
2.4 GHz RF Transmitter
MODEL 38-1400-DC – Rev.3
DESCRIPTION
The A
IR
-E
AGLE
SR,
MODEL
38-1400-DC
I
s an R.F. transmitter capable
of sending up to four dry contact input commands to the Air-Eagle SR
Receiver, model 38-2000 or 38-8000. The TX and RX combine to
create a short range radio frequency system that operates hazardous
or hard-to-reach electrical apparatus from safe, convenient locations of
up to 300 feet away. This unit is user-programmable for up to 128
digital addresses and eight network frequencies to allow multiple
transmitters and receivers to operate simultaneously in the same area
without interference.
INSTALLATION
1.
Mount the A
IR
-E
AGLE
SR TRANSMITTER in a convenient location
2.
Install wiring to contact input terminal strip.
3.
Connect DC power and control to the proper terminals in your control
circuit.
DIGITAL ADDRESS & FREQUENCY SET-UP
This transmitter is factory programmed to Frequency #1 and Digital
Address “0”. These settings can be changed by the user in any
combination
but must match the receiver that is set up to
communicate with this transmitter
.
If using this transmitter with a
model 38-2000 4-relay receiver, the digital address
must be kept at
the default of Digital Address “0”.
1)
Remove top cover.
2)
Select desired address and/or network frequency
3)
Move SW4 on SEL2 to the “CLOSED” position. The TX LED will
illuminate (no data is being transmitted during this programming)
4)
Once LED is illuminated, move SW4 on SEL2 back to the
“OPEN” position. The TX LED will extinguish.
5)
Programming is now complete. Replace top cover.
Note – Selected address and frequency settings will be maintained, in
the internal flash memory, even if power is removed from unit. The
above procedure needs to be performed only if
changing
digital
address and/or network frequency)
SEL1
(ADDRESS)
Seven dip switches for selecting digital address of this
transmitter (Maximum of 128 combinations)
Network
Address
SW1
SW2
SW3
1
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
3
OPEN
CLOSED
OPEN
4
CLOSED
CLOSED
OPEN
5
OPEN
OPEN
CLOSED
6
CLOSED
OPEN
CLOSED
7
OPEN
CLOSED
CLOSED
SEL 2 (SW 1-3):
(NETWORK
FREQUENCY)
8
CLOSED
CLOSED
CLOSED
Normal Operation
Programming
SEL2 (SW4)
OPEN
CLOSED
Dimensions (with mounting plate) 6.3” L x 4.8” W x 2.3” H
TERMINAL STRIP WIRING
1
Ch1 Input (+)
5
Ch3 Input (+)
9
(-) 9-36 VDC INPUT
2
Ch1 Input (C)
6
Ch3 Input (C)
10
(+) 9-36 VDC INPUT
3
Ch2 Input (+)
7
Ch4 Input (+)
4
Ch2 Input (C)
8
Ch4 Input (C)
CONTROLS & INDICATORS
TX LED
Illuminates continuously while any button is
depressed and unit is transmitting.
Dry Contact Inputs
Transmits individual RF codes to the
receiver