8. FACTORY SETTINGS MENU POINTS

The factory-set values can be checked and, if needed, modified by entering the factory menu. To 

enter the factory menu, first turn the thermostat off. The display will only show the             brand 

letters in the upper right corner. Now touch and keep depressed at the same time the        and 

the           buttons for at least 5 seconds. On entering the first point of the factory menu will ap-

pear: by default the temperature numerical value shows 0.0°C and menu point 01 appears in the 

right bottom corner of the display. This menu makes it possible to set the difference between 

the temperature shown by the thermostat and the real temperature of the room. You can set 

the temperature difference with the correct sign by touching the         or         button several times, 

as needed. If, for instance, the thermostat, when turned on, shows 21.5°C and the real tempera-

ture of the room is 20.0°C, then you have to set a value of -1.5°C in menu point 01 of the factory 

settings. For approval and proceeding touch the              button once briefly. 

Attention!

 Saving of 

the settings will take place automatically even if no further steps follow and in about 15 seconds 

the thermostat will turn off. In the factory menu (after entering it again or setting menu 01 by 

touching the               button) you can proceed always by touching the            button briefly, and in 

the individual menu points you can use the         or          button for setting the values. 

DEFAULT VALUES

Description

Range

Default

01

Temp. Offset

-8°C ~ 8°C

0

02

Set Point Max.

5°C ~ 80°C

35°C

03

Set Point Min.

5°C ~ 80°C

5°C

04

Sensor Select

ROOM

 

SURFACE

Room + Surface

05

Frost Protection Temp.

5°C ~15°C

5°C

06

Surface Temp. Display

Read Only

07

High Temp. Protection

10°C ~ 80°C

32°C

11

Reset

rE(Yes)

12

Key lock

0 - off, 1 - on

0

13

Master ID address

Read Only

14

OWD function ON/OFF Select

0 - off, 1 - on

0

15 

OWD Detect Time Select 

2 ~ 30 mins 

15 

mins 

16

OWD Drop Temp. Select (within detect 

time)

2 / 3 / 4°C

2°C

17

OWD Delay time select (Return to previous 

working status)

10 ~ 60 mins

30 

mins

18

The temp. diff to exit high protection mode

1°C ~ 3°C

1°C

19

External sensor temp. offset

-8°C ~ 8°C

0

20

Energy optimisation

1: electric radiator                3: ceiling heating

2: heating panel                    4: floor heating 

2

21

Brightness (Standby Mode)

0 - 100%

5%

22

Software version

Read Only

23

Read Only

Summary of Contents for Heato9

Page 1: ...bvfheating com BVF Heato9 Programmable room thermostat DETAILED USER MANUAL...

Page 2: ...3 2 Technical data dimensions switching current connection 3 3 Installation 4 4 Electrical connection 6 5 Display 7 6 Fix modes of operation 8 7 Programming 9 8 Factory settings menu points 10 9 Faul...

Page 3: ...ntrolled equipment and make the guarantee null and void 2 TECHNICAL DATA dimensions switching current connection Supply voltage 230V AC 50 60 Hz Relay loadability 3600W 16A recommended max 3200W 14A S...

Page 4: ...possible install the the heating system at a temperature above 5 C 3 The front and rear panels of the thermostat are connected by a pin type connector Upon removing the front panel this connector sli...

Page 5: ...5 MOUNTING Electrical box recessed into the wall 65x 55mm horizontal screw locations...

Page 6: ...the neutral blue wire of the electrical resistance based heating element here 4 Phase output Connect the phase brown conductor of the electrical resistance based heating element here Attention The hea...

Page 7: ...sponding to the application and the related temperature can be set Setting of the programming is detailed in menu point 7 BVF logo In the upper right corner of the display the logo indicates the stand...

Page 8: ...rmostat and to be achieved will not change until the or button is touched The steady temperature values make quick setting possible to provide constant temperatures with time inde pendent unchanged va...

Page 9: ...isplay and the pp hh mm indication starts flashing in the right bottom corner Just like above set the next starting time of the daily program cycle The start of the 2nd program cycle will logically in...

Page 10: ...ttention Saving of the settings will take place automatically even if no further steps follow and in about 15 seconds the thermostat will turn off In the factory menu after entering it again or settin...

Page 11: ...a value higher than that even in the case when the room has not reached the desired temperature value A setting recom mended for floor or ceiling heating operated as an independent mode of heating 05...

Page 12: ...he time specified here If the numerical value of the menu is 30 it means that heating will be switched on again 30 minutes after the temperature drop has stopped An example of how the open window func...

Page 13: ...h it on again YES The thermostat has switched on the ribbon cable has pressed the front panel when replacing the front panel take care to insert the ribbon cable in the small gap on the rear side NO s...

Page 14: ...limit values as described in the instructions manual If necessary the setting limit value can be increased If the surface temperature shows an unrealistic value further examination is required If ther...

Reviews: