10
8. FACTORY SETTINGS MENU POINTS
The factory-set values can be checked and, if needed, modified by entering the factory menu. To
enter the factory menu, first turn the thermostat off. The display will only show the brand
letters in the upper right corner. Now touch and keep depressed at the same time the and
the buttons for at least 5 seconds. On entering the first point of the factory menu will ap-
pear: by default the temperature numerical value shows 0.0°C and menu point 01 appears in the
right bottom corner of the display. This menu makes it possible to set the difference between
the temperature shown by the thermostat and the real temperature of the room. You can set
the temperature difference with the correct sign by touching the or button several times,
as needed. If, for instance, the thermostat, when turned on, shows 21.5°C and the real tempera-
ture of the room is 20.0°C, then you have to set a value of -1.5°C in menu point 01 of the factory
settings. For approval and proceeding touch the button once briefly.
Attention!
Saving of
the settings will take place automatically even if no further steps follow and in about 15 seconds
the thermostat will turn off. In the factory menu (after entering it again or setting menu 01 by
touching the button) you can proceed always by touching the button briefly, and in
the individual menu points you can use the or button for setting the values.
DEFAULT VALUES
Description
Range
Default
01
Temp. Offset
-8°C ~ 8°C
0
02
Set Point Max.
5°C ~ 80°C
35°C
03
Set Point Min.
5°C ~ 80°C
5°C
04
Sensor Select
ROOM
SURFACE
Room + Surface
05
Frost Protection Temp.
5°C ~15°C
5°C
06
Surface Temp. Display
Read Only
07
High Temp. Protection
10°C ~ 80°C
32°C
11
Reset
rE(Yes)
12
Key lock
0 - off, 1 - on
0
13
Master ID address
Read Only
14
OWD function ON/OFF Select
0 - off, 1 - on
0
15
OWD Detect Time Select
2 ~ 30 mins
15
mins
16
OWD Drop Temp. Select (within detect
time)
2 / 3 / 4°C
2°C
17
OWD Delay time select (Return to previous
working status)
10 ~ 60 mins
30
mins
18
The temp. diff to exit high protection mode
1°C ~ 3°C
1°C
19
External sensor temp. offset
-8°C ~ 8°C
0
20
Energy optimisation
1: electric radiator 3: ceiling heating
2: heating panel 4: floor heating
2
21
Brightness (Standby Mode)
0 - 100%
5%
22
Software version
Read Only
23
Read Only