bvfheating.com

BVF Heato9

Programmable room thermostat

DETAILED USER MANUAL

Summary of Contents for Heato9

Page 1: ...bvfheating com BVF Heato9 Programmable room thermostat DETAILED USER MANUAL...

Page 2: ...3 2 Technical data dimensions switching current connection 3 3 Installation 4 4 Electrical connection 6 5 Display 7 6 Fix modes of operation 8 7 Programming 9 8 Factory settings menu points 10 9 Faul...

Page 3: ...ntrolled equipment and make the guarantee null and void 2 TECHNICAL DATA dimensions switching current connection Supply voltage 230V AC 50 60 Hz Relay loadability 3600W 16A recommended max 3200W 14A S...

Page 4: ...possible install the the heating system at a temperature above 5 C 3 The front and rear panels of the thermostat are connected by a pin type connector Upon removing the front panel this connector sli...

Page 5: ...5 MOUNTING Electrical box recessed into the wall 65x 55mm horizontal screw locations...

Page 6: ...the neutral blue wire of the electrical resistance based heating element here 4 Phase output Connect the phase brown conductor of the electrical resistance based heating element here Attention The hea...

Page 7: ...sponding to the application and the related temperature can be set Setting of the programming is detailed in menu point 7 BVF logo In the upper right corner of the display the logo indicates the stand...

Page 8: ...rmostat and to be achieved will not change until the or button is touched The steady temperature values make quick setting possible to provide constant temperatures with time inde pendent unchanged va...

Page 9: ...isplay and the pp hh mm indication starts flashing in the right bottom corner Just like above set the next starting time of the daily program cycle The start of the 2nd program cycle will logically in...

Page 10: ...ttention Saving of the settings will take place automatically even if no further steps follow and in about 15 seconds the thermostat will turn off In the factory menu after entering it again or settin...

Page 11: ...a value higher than that even in the case when the room has not reached the desired temperature value A setting recom mended for floor or ceiling heating operated as an independent mode of heating 05...

Page 12: ...he time specified here If the numerical value of the menu is 30 it means that heating will be switched on again 30 minutes after the temperature drop has stopped An example of how the open window func...

Page 13: ...h it on again YES The thermostat has switched on the ribbon cable has pressed the front panel when replacing the front panel take care to insert the ribbon cable in the small gap on the rear side NO s...

Page 14: ...limit values as described in the instructions manual If necessary the setting limit value can be increased If the surface temperature shows an unrealistic value further examination is required If ther...