Installation of low-voltage cable and suction pipes
The 5 V of control lines leading to the individual inlet valves are to be connected in a
parallel circuit (tree network). It is possible to connect each inlet valve with a separat ca-
ble to the BVC central vacuum cleaner (star network). Installing the 5 V cable next to a
230 V cable can cause electrical interference with the control system.
5 V low voltage cable
vac pan
to unit
to unit
right
wrong
Descending and ascen-
ding pipes must not be in
alignment, but have to
be staggered.
Install the safety pipe
elbow behind every
suction valve.