background image

3

BEFORE USE

1.  Before  using  this  product,  read  the  instruction  manual 

completely  and  familiarize  yourself  thoroughly  with  the 

product  and  the  hazards  associated  with  its  improper 

use.

2. Know your pump, its limitations and how it operates before 

attempting to use

3. Use Spare Parts List Illustration on pages 6 & 8 as reference 

of location and assembly.

4. Replace shipping plug (red color) with air vent plug (black 

color). Refer to #58 on parts illustration. 

ASSEMBLY

To hook up pump with remote control:

1. Connect 

red

 hose into air line coupler number 1 on the pump 

and then put other end of red hose into  corresponding slot 

on remote control

2. Connect 

purple

 hose into air line coupler number 2 on 

the  pump  and  then  put  other  end  of  purple  hose  into 

corresponding slot on remote control.

3. Connect 

white

 hose to air line coupler number 3 on the 

pump  and  then  put  other  end  of  the  white  hose  into 

corresponding slot on remote control. 

Note

: Always  secure  threaded  port  connections  with  non-

hardening pipe thread compound. Tighten securely to prevent 

accidental removal of components while in use.

 

Take care not 

to introduce compound into port orifices.

•  Study,  understand,  and  follow  all 

instructions provided with and on this 

device before use.

•  All WARNING statements must be 

carefully  observed  to  help  prevent 

personal injury.

•  No alteration shall be made to this 

device.

•  Always  wear  protective  gear  when 

operating hydraulic equipment.

•  Keep hydraulic equipment away from 

flames and heat. Hydraulic fluid can 

ignite  and  burn.  Do  not  operate  if 

leaks are detected.

• 

Crush Hazard. 

Keep hands and feet 

away from loading area. Avoid pinch 

points  or  crush  points  that  can  be 

created by the load, cylinder, or any 

equipment of system.

• To avoid crushing and related injuries:

  NEVER  work  on,  under  or  around 

a  lifted  load  before  it  is  properly 

supported by appropriate mechanical 

means.  Never  rely  on  hydraulic 

pressure alone to support load.

!

   

WARNING

HYDRAULIC PUMPS

•  The  user  must  be  a  qualified  operator  familiar  with  the 

correct operation, maintenance, and use of pumps. Lack of 

knowledge in any of these areas can lead to personal injury.

• Do not exceed rated capacity of the pump or any equipment 

in the system. 

• Never attempt to lift a load weighing more than the capacity 

of the cylinder. 

• Burst hazard exists if hose or connection pressure exceeds 

rated pressure.

•  Do  not  subject  the  pump  and  its  components  to  shock 

loads.

• Inspect pump, cylinder, hoses and connections before each 

use  to  prevent  unsafe  conditions  from  developing.  Do  not 

use  if  they  are  damaged,  altered  or  in  poor  condition.  Do 

not  operate  the  system  with  bent  or  damaged  coupler  or 

damaged threads.

•  Never  hold  or  stand  directly  in  line  with  any  hydraulic 

connections while pressurizing.

• Use gauge or other load measuring instrument to verify load. 

• Never attempt to disconnect hydraulic connections under 

pressure. Release all line pressure before disconnecting 

hoses.

•  Use only approved accessories and approved hydraulic fluid.

•  Never attach ANY component not authorized by manufacturer.

•  Always ensure that the chosen application is stable to work 

on and around.

• Do not connect to application  which can return more oil to 

the reservoir than the pump reservoir can hold. 

•  Do  not  connect  pump  to  hydraulic  system  powered  by 

another pump.

•  This device is not suitable for use as support device! As 

the system load is lifted, use blocking and cribbing to guard 

against a falling load.

•  All  personnel  must  be  clear  before  lowering  load  or 

depressurizing the system.

•  Never try to disassemble a hydraulic cylinder, refer repairs 

to qualified, authorized personnel.

HYDRAULIC HOSES & FLUID TRANSMISSION LINES

•  Avoid short runs of straight line tubing. Straight line runs 

do not provide for expansion and contraction due to 

pressure and/or temperature changes.

• Reduce stress in tube lines. Long tubing runs should be 

supported by brackets or clips.  Before operating the pump, 

tighten  all  hose  connections  with  proper  tools.  Do  not 

overtighten. Connections should only be tightened securely 

and leak-free. Overtightening can cause premature thread 

failure or high pressure fittings to burst.

• Should a hydraulic hose ever rupture, burst or need to be 

disconnected, immediately shut off the pump and release 

all pressure. Never attempt to grasp a leaking pressurized 

hose with your hands. The force of escaping hydraulic fluid 

can inflict injury.

• Do not subject the hose to potential hazard such as fire, 

sharp objects, extreme heat or cold, or heavy impact.

•  Do not allow the hose to kink, twist, curl, crush, cut or bend 

so tightly that the fluid flow within the hose is blocked or 

reduced. Periodically inspect the hose for wear.

•  Do not pull, position or move setup by the hose.

•  Hose material and coupler seals must be compatible with 

hydraulic fluid used. Hoses also must not come in contact 

with  corrosive  materials  such  as  battery  acid,  creosote-

impregnated objects and wet paint. Never paint a coupler 

or hose.

• FAILURE TO HEED THESE WARNINGS MAY RESULT IN 

PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

Summary of Contents for PA1500L

Page 1: ...53 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com Maximum Operating Pressure 10 000 PSI PA1500L M0 rev 08 07 This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Page 2: ...to a shock load a load dropped suddenly causing the system pressure to exceed 10 000 PSI shall be removed from service immediately until checked out by a BVA Hydraulics authorized service center Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment may require special training and knowledge PRODUCT DESCRIPTION BVA Hydraulics Air Hydraulic Pumps ...

Page 3: ...Inspect pump cylinder hoses and connections before each use to prevent unsafe conditions from developing Do not use if they are damaged altered or in poor condition Do not operate the system with bent or damaged coupler or damaged threads Never hold or stand directly in line with any hydraulic connections while pressurizing Use gauge or other load measuring instrument to verify load Never attempt ...

Page 4: ...mperature extremes 4 For transportation or long storage replace the air vent plug with shipping plug 5 Shield pump with a protective cover OPERATION To reduce the risk of personal injury and or property damage hydraulic connections must be securely fastened before building pressure in the system Release all system pressure before loosening any hydraulic connection in the system Always monitor pres...

Page 5: ...medy overload condition Contact Service Center Replace application connection Application responds slower than normal Loose connection or coupler Restricted hydraulic line or fitting Application connection leaking Tighten connection or coupler Clean and replace if damaged Replace application connection Application does not return fluid to pump i e cylinder will not retract Malfunctioning coupler dam...

Page 6: ...nd position in the assembly sequence Note To ensure safe and reliable performance replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only MODEL PA1500L Air Hydraulic Pump Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com ...

Page 7: ... 7 0120 105 Back up ring 1 43 U cup 1 44 A59 6 1013 105 Pump piston cylinder 1 45 A57 6 1016 106 Spacer 1 46 H18 6 8103 104 Crush washer Steel and rubber 1 47 A57 6 1001 204 Base hydraulic unit 1 48 A57 6 1605 105 Gasket 1 49 511 7 0140 200 O ring 2 50 A57 3 5002 107 Remote control assy 1 51 A57 6 5309 101 Air hose 1 52 A17 6 1105 103 Manifold plug air 1 53 A57 6 2062 108 Air inlet connector H17x4...

Page 8: ...nd position in the assembly sequence Note To ensure safe and reliable performance replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only MODEL PA3801L Air Hydraulic Pump Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com ...

Page 9: ...11 108 Piston assy 1 40 512 2 0410 017 Compression spring 1 Parts List Item Part Number Description Qty 41 A57 6 1014 102 Piston cover 1 42 A57 6 2023 108 Bushing 1 43 Back up ring 1 44 U cup 1 45 A59 6 1013 105 Pump 1 46 A57 6 1016 106 Washer 1 47 Special washer 1 48 A57 6 1001 204 Base 1 49 Pad B 1 50 O ring 2 51 A57 3 5002 107 Air control assy 1 52 A57 6 5309 101 Air tubes 1 53 A17 6 1105 103 P...

Page 10: ...VA Hydraulics product fails due to material defect in workmanship you may contact SFA for disposition In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITE...

Page 11: ...SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com ...

Page 12: ...SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com ...

Reviews: