background image

BEFORE USE

Read, understand, and follow 

all

 printed materials carefully 

before attempting to assemble or operate these pumps.

NOTICE: 

E-Pumps are shipped dry. Add oil before use.

Electrical Connections:

Compare motor nameplate against power availability

to prevent motor burnout and dangerous electrical

overloading. The motors are wired for 380 volts unless 

otherwise specified. 

DANGER:  

Motor, connections and remote on/off switch 

are  energized components containing line voltage.  

Ensure supply is grounded and GFI protected.

Hydraulic Connections:

1. Make sure to use the hydraulic oil specified by the 

manufacturer. Ensure oil level in reservoir is ~ 

2"

 from top 

of reservoir plate, with cylinders retracted and motor off.

2. Use of pressure gauge is strongly recommended. Attach a 

pressure gauge between the pump and cylinder to monitor  

pressure on cylinder.

3. Make sure coupler, hose, valve, gauge are tighten  securely 

to prevent accidental removal of components while in use. 

Hoses 

must

 not be kinked or twisted.

NOTICE

Always secure threaded port connections with non-

hardening pipe thread compound. Take care not to introduce 

compound into port orifices. 

To ensure smooth operation, bleed air from the system by fully 

advancing and retracting the cylinder several times.

4. Do not exceed the rated capacity of the equipment connected 

to the pump. Ensure that 

all hydraulic equipment used 

with this pump is rated at 10,000 psi or greater

OPERATION 

WARNING:  

ALWAYS monitor pressure, force and load 

position.  Pressure may be monitored by means of an 

optional manifold and gauge. Force may be monitored 

by means of a load cell and digital indicator. Correct 

application position can only be determined by the 

operator of the equipment.

1. Check oil level, add oil if necessary.

2. Make sure system fittings and connections are tight and 

leak free.

3. Place control valve lever in the middle (Neutral/Hold) 

position  to prevent accidental lifting or moving of load.

4. To 

start 

the motor:  Toggle the ON/OFF switch located on 

the control box to 'ON' position 

OR

 for momentary use: 

     Leave control box switch in the 'OFF' position and toggle 

remote ON/OFF pendant switch. 

5. It is recommended to use to ON/OFF switch at the 

control 

box

 to let the pump idle for a few minutes before putting 

into operation.

WARNING:  

This pump is for use with a single acting 

cylinder ONLY! Connect one hose from either pump 

oil output port to the input port of a single acting 

application such as a cylinder. Block the unused output 

port securely. This model can not be used with double 

acting cylinders.

6. Use the control valve lever to control the direction of fluid 

flow. These pumps are equipped with a 3-way 3-position 

valve for use with single acting cylinder applications 

ONLY

Refer to Figure 3 below for the flow path.

7. Always monitor the pressure, load and position.

8. Do not exceed the rated capacity of the equipment 

connected to the pump. To 

reduce

 system component 

stress, material fatigue, and the risk of personal injury 

and property damage, 

never

 load a hydraulic application 

(cylinder, spreader, etc.) to more than 80% of its rated 

capacity. 

9. Shift the control valve until the desired pressure, load or 

position is reached. 

Note:

 Do not continue to operate pump 

after cylinder plunger is fully extended or retracted.

10. To 

turn off 

the motor:  Toggle the ON/OFF switch on the 

control box to 'OFF' position. 

11. Depressurize all connections before disconnect. If you 

have any questions, call BVA Technical Service @ (888)-

332-6419.

Position 1 (Advance):

 

Pressured oil flows to port A. 

Position 3 (Retract):

  

Port A returns flow to 

tank.

Position 2 (Hold):

 

Neutral, ports A is 

closed. Hold Position.

Port  A              

Port  A             

Port  A             

P                    T

P                   T

Figure 3- Schematic flow path, valve position of 3-way, 3-position valve for Single Acting Cylinder

Port A

Port B

1

2

3

5

 

!

 

!

 

!

P                   T

Summary of Contents for PE60M3N06J

Page 1: ... City MO 64153 Tel 888 332 6419 Fax 816 448 2142 E mail sales bvahydraulics com Website www bvahydraulics com Model PE60M3N06J Maximum Operating Pressure 10 000 PSI This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Page 2: ...IPTION This Pump is engineered to meet most industrial standards for Performance and Safety Its allows quick displacement of hy draulic fluid under no load conditions and easy pumping in loaded conditions This electric hydraulic pump supplies compressed hydraulic fluid to compatible single acting applications ONLY Such applications include rams presses spreaders compactors and crimping machines an...

Page 3: ...ht w Oil lbs 1st Stage 2nd Stage 1st Stage 2nd Stage PE60M3N06J 6 600 800 10 500 421 525 98 122 3 way 3 position Hold Run 3 0 460 202 PE60M4N06J 4 way 3 position 3 Figure 1 Typical 3 way 3 position PE series Electric Pump Components PE60M4N06J shown Electric Motor ON OFF Switch Control Valve Electric Motor Control Box Control Valve Lever Drain Plug Reservoir Power Cord Oil Output Ports ...

Page 4: ...te this device in an extreme temperature explosive atmosphere or in the presence of conductive liquids Always inspect hoses and connections for damage prior to use Ensure the device is placed on a hard level surface Ensure that application is stable to work on and around Use only approved accessories and approved hydraulic fluid Never attach ANY component not authorized by manufacturer Do not conn...

Page 5: ...nd connections are tight and leak free 3 Place control valve lever in the middle Neutral Hold position to prevent accidental lifting or moving of load 4 To start the motor Toggle the ON OFF switch located on the control box to ON position OR for momentary use Leave control box switch in the OFF position and toggle remote ON OFF pendant switch 5 It is recommended to use to ON OFF switch at the cont...

Page 6: ...ed Use only good quality hydraulic oil We recommend BVA hydraulic oil F01 F05 ISO 46 or equivalent To order the oil refer to service parts section Use only the manufacturers recommended hydraulic oil Use of other hydraulic oil may result in pump failure and will void warranty Adding Hydraulic Oil 1 Make sure electric motor is OFF 2 Depressurize and disconnect hydraulic hose from application Sympto...

Page 7: ...a convenient reference of location and position in the assembly sequence Item Part Number Description QTY 1 E35 4 9320 103 3 H P 3PH Motor Assembly 1 1 1 649 1 0120 030 Bolt 4 1 2 605 3 0120 025 Gasket 4 2 E35 1 2000 102 3 H P Motor Pump Assembly 1 3 E35 4 9015 108 Reservoir Assembly 1 3 1 E11 3 6005 100 Screen 1 3 2 E11 6 7002 107 Pipe Nipple 1 3 3 E11 6 3007 107 Drain Line 1 3 4 601 3 0064 106 G...

Page 8: ... 6 9001 109 Gasket 1 4 E08 4 2000 107 Adaptor Assy 1 5 E35 6 9003 103 Reservoir Cover 1 6 E35 6 3001 109 Motor Mount 1 7 E35 6 3002 101 Shaft Adaptor 1 8 E60 6 9002 100 Key 1 9 N A Upper Plate Assy 1 10 649 1 0095 204 Screw 4 11 N A Eccentric 5 8 Shaft 1 12 622 6 0318 203 Bearing Needle 1 13 E05 6 9007 107 Sleeve Eccentric Bearing 1 14 E30 4 4000 105 see page 9 for details Piston Block Assy 4 15 5...

Page 9: ...ics com Not all components of the pump are replacement items but are illustrated as a convenient reference of location and position in the assembly sequence 3 2 6 7 4 5 6 1 Item Part Number Description QTY 1 E30 6 4000 107 Piston 1 2 Spring 1 3 N A Piston Block 1 4 H18 6 8103 104 Washer 1 5 E05 6 4002 102 Hex Head Plug 1 6 O Ring 2 7 Ball 1 8 O Ring 2 E15 3 9940 101 Piston Block Assembly Repair Ki...

Page 10: ...nce of location and position in the assembly sequence 3 4 10 11 3 5 3 3 6 13 1 Item Part Num Description QTY 1 511 7 0095 100 2 2 N A Upper Gear Plate Assy 1 3 667 5 0127 005 4 4 E15 6 6002 100 Drive Shaft Gear Pump 1 5 E15 6 6003 102 Idler Shaft Gear Pump 1 6 E05 6 3001 105 2 7 E15 6 6004 104 Gear 2 8 E15 6 5001 103 2 9 N A Center Gear Plate 1 10 N A Lower Gear Plate Assy 1 11 433 6 2401 106 Park...

Page 11: ...er Hex Plug 1 2 Metal Seal 1 3 Tapered Spring 1 4 601 7 0008 009 Chrome Steel Balls 1 4 1 5 E05 4 8002 100 Stick Valve Assy 1 6 N A Block unloading 1 7 O ring 2 8 E05 6 8001 201 Unloading PIn 1 9 Chrome Steel Balls 3 8 1 10 E05 6 8005 108 Ball Retainer 1 11 Low Pressure Spring 1 Item Part Number Description QTY 12 641 1 0158 105 Socket Head Set Screw 1 13 641 1 0127 104 Socket Head Set Screw 1 14 ...

Page 12: ...A Hydraulics product fails due to material defect in workmanship you may contact SFA for dis position In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITE...

Reviews: