BV BV-WF-01 Installation Manual Download Page 2

2

Remove wiring box from fan: 

Unplug motor, loosen screw and remove electrical 

wiring box cover.

Push electrical wiring box into housing and lift out.
NOTE: For easier removal of wiring box, remove 

the motor assembly. Loosen the  mounting 

screws and rotate the motor assembly. 

Determine  desired  air  flow  direction,  and  orient 

fan housing accordingly.  

INSTALLATION

NOTE: Fan can be installed in walls up to 5-1/8″ 

thick. For walls less than 4-1/2″ thick, a trim board 

frame  is  needed  for  spacing  (see  Step  9).  Fan 

can be operated by a wall switch or speed control 

(available separately).

WARNING

: When cutting or drilling into wall, do 

not cut existing electrical wiring. 

CAUTION

: Before cutting opening, make sure to 

mark center of opening on two sides of wall.
Carefully  cut  out  fan  openings  and  switch  box 

opening.

1

SWITCH OR SPEED CONTRO

L

FAN

2

3

MOTOR ASSEMBL

Y

WIRING BOX

AIRFLOW DIRECTIO

N

WALL OPENING

Summary of Contents for BV-WF-01

Page 1: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Page 2: ...INSTALLATION NOTE Fan can be installed in walls up to 5 1 8 thick For walls less than 4 1 2 thick a trim board frame is needed for spacing see Step 9 Fan can be operated by a wall switch or speed con...

Page 3: ...move knockout on wiring box using flat blade screwdriver and pliers Fasten electrical cable to wiring box with proper connector for type of wire used Provide 6 leads inside box for electrical connecti...

Page 4: ...d of plaster or patching compound along edge of housing to fill gap between housing and wall PLASTER FRAME 7 8 Install mounting brackets from inside of fan housing and pull them tightly against back o...

Page 5: ...ANTY This is a quality product It was made with care and BV offers a limited one year warranty against any manufacturing defects as long as it has been used as directed BV will replace any product sho...

Page 6: ...e construcci n etc fuera de la unidad de potencia 3 Lea la etiqueta de especificaciones del producto para obtener m s informaci n y requisitos 4 No utilizar en el ba o 5 Para reducir el riesgo de lesi...

Page 7: ...nstalar en paredes de hasta 5 1 8 de grosor Para paredes de menos de 4 1 2 de grosor se necesita un marco de tablero de compensaci n para el espaciado consulte el Paso 9 El ventilador puede ser operad...

Page 8: ...ciegos de la caja de cableado con un destornillador de punta plana y unos alicates Sujete el cable el ctrico a la caja de cableado con el conector adecuado para el tipo de cable utilizado Proporcione...

Page 9: ...orde del alojamiento para llenar el espacio entre el alojamiento y la pared 7 8 Instale los soportes de montaje desde el interior del alojamiento del ventilador y j lelos firmemente contra la parte po...

Page 10: ...calidad Fue hecho con cuidado y BV ofrece una garant a limitada de un a o contra cualquier defecto de fabricaci n siempre que se haya utilizado seg n las instrucciones BV reemplazar cualquier product...

Reviews: