3.1.6. Line pressure should be increased to compensate for unusually long air 

hoses (over 8 metres). The minimum hose 

diameter should be 1/4” I.D. and 

fittings must have the same inside dimensions. 

3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and 

make certain that all connections are secure. 

3.2. Couplings 

Vibration may cause failure if a quick change coupling is connected directly to the 
tool. 
To overcome this, connect a leader hose to the tool. A quick change coupling 
may then be used to connect the leader hose to the air line recoil hose. See fig.1 
and fig.2. 

4. OPERATING INSTRUCTIONS

Ensure you read, understand and apply   
safety instructions before use.

 

WARNING! Unplug from the air supply   
before placing bit into chuck.

 

4.1. DRILL BIT FITTING. 

Regularly check the drill bit and always change if worn, 

cracked or otherwise damaged. 

4.1.2. Open or close the chuck jaws to a point where the opening is slightly larger 

than the drill or tool bit to be used by unscrewing the chuck .Insert the drill 
bit into the chuck as far as it will go. Tighten the chuck securely.   

4.2. 

Connect air supply to drill. Squeeze the trigger to check that the drill is 