Using the device
MT iQ Basic Pro
EN
12
I
5. Wait for about 10 seconds.
✔
The battery capacity is stored.
9.4
Hall sensor calibration
I
1. Push and hold the button (fig.
1
) for 5 seconds to enter the setup menu.
2. Push the button to navigate in the setup menu.
3. Select the
RESET 0.0A
and push and hold the button until the
OK
is displayed.
4. Wait for about 10 seconds.
✔
The Hall sensor is successfully calibrated.
10
Using the device
10.1
Switching On/Off
➤
Push the button (fig.
1
) to turn on the device.
I
10.2
Functions
➤
Push the button (fig.
1
) to switch between the displayed values.
I
• The remaining battery capacity (Ah).
• The remaining battery capacity (%).
NOTE
• Keep the button pressed to change the values more quickly.
• Settable capacity between 10 Ah - 999 Ah.
NOTE
• The calibration is only necessary if there is definitely no current flowing and the dis-
play does not show
0.0 A
.
• Make sure no consumers can draw current from the battery. If necessary, remove
the cables from the Hall sensor opening.
NOTE
• If the button (fig.
,
1
) is inactive for 30 seconds, the display back light turns off.
• If the button (fig.
,
1
) is inactive for 120 min, the display turns to standby mode.
The measurement continues in the background and is indicated by the
P
flashing
symbol.
NOTE
If the display back light is off, the firs press only turns on the back light and the second
press switches the value.