Butterfly Energy System Air Intelligence Series BESM-09AI2X User Manual And Installation Manual Download Page 28

66129915028

Summary of Contents for Air Intelligence Series BESM-09AI2X

Page 1: ...ems please review user manual and installa on guide before installa on and retain for future reference Bu erfly Energy Systems Air Intelligence Series User Manual and Installa on Guide For Indoor Head...

Page 2: ......

Page 3: ...WLFOH LOWHU 22 Never attempt Be sure to follow this instruction The physical product may differ from the drawing in this manual for different display If there are some differences between them please...

Page 4: ...To avoid injury do not touch moving pieces or apply force to moving pieces in any manner 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening This many cause injury ele...

Page 5: ...ased so room heating capacity If outdoor temperature got lower please operate with the other heating ventilating equipments Defrosting When outdoor temperature is low but high humidity after a long wh...

Page 6: ...3 Names and functions of each part Indoor unit Front panel Filter Guide louver Wall pipe Bind tape Connection pipe Drainage pipe Remote controller Air in Air out...

Page 7: ...se temperature setting Press it to decrease temperature setting FAN Press it to set swing angle TIMER ON TIMER OFF CLOCK X FAN page 8 TEMP page 8 TURBO page 8 SLEEP page 8 Press it to turn on off the...

Page 8: ...fter pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display 21 outdoor ambient temperature and blank is displayed circularly TEMP icon set temperature indoor ambi...

Page 9: ...button to set up down swing angle which circularly changes as below OFF 1 2 3 4 5 6 Operation of Remote Controller 6 After energization AUTO mode is defaulted In AUTO mode the set temperature will no...

Page 10: ...d off the unit After energization X FAN OFF is defaulted X FAN is not available in AUTO FAN or HEAT mode Press this button to activate deactivate the Turbo function which enables the unit to reach the...

Page 11: ...sert them after 30 seconds If it still can t operate Sketch map for replacing batteries Notes Remove the battery cover plate from the rear of the remote controller Replacement of Batteries properly re...

Page 12: ...ue and fan speed The manual switch can be operated as follow At operation When the unit stopped running press ON OFF button unit will enter into AUTO RUN mode The microcomputer will accord to the room...

Page 13: ...nd take it out forcibly and then can take it off Washing Install front panel Place two supporters of the front panel into the slots along the direction of arrows to cover and clasp the front panel As...

Page 14: ...r unit to prevent it from spreading a b Clean and care Take down the air filter Cleaning Reinsert the filters Reinsert the filters along with the arrow head then cover the surface panel and clasp it T...

Page 15: ...l not operate in approximately 3 minutes to protect itself The unit can not operte immediately when the air conditioner is restarted There s unusual smell blowing from the outlet after operation is st...

Page 16: ...dirty Are the windows and door closed Is indoor fan speed set at low speed Is there any other heat source in your room Cooling Heating efficiency is not good Remote controller can t be used occasional...

Page 17: ...low that will stop deliver air in order to prevent cool air Within 3min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger...

Page 18: ...ough the whole room 2 Select a position where the condensing water can be easily drained out and the place is easily connected for outdoor unit 3 Select a location where the children can not reach 4 C...

Page 19: ...that professional personnel consider them unreliable Note Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reli...

Page 20: ...lation dimension diagram Space to the ceiling Above Above Space to the wall Space to the wall 15cm Above 300 cm 2 15 cm Space to the floor Air outlet side Above cm 250 Installation dimension diagram 1...

Page 21: ...into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Installation of Drain Hose Indoor Outdoor Wall pipe Seal pad Fig 1 1 Connect the drain hose...

Page 22: ...tric wire if the wire length is not enough please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed The electric w...

Page 23: ...water pipe with tape and put them th rough the piping hole As show in Fig 4 upper tabs of the rear panel and check if it is firm enough As show in Fig 5 Install the connection pipe the nut with spann...

Page 24: ...arth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooling...

Page 25: ...before cleaning and reinstall it after cleaning Installation and Maintenance of 0LFUR 3DUWLFOH LOWHU 0LFUR 3DUWLFOH LOWHU Air filter 0LFUR 3DUWLFOH LOWHU downwards to remove it See Fig a Mount the 0LF...

Page 26: ...dditional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection p...

Page 27: ...Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m 6 9 5 or 12 20 15 20 6 or 9...

Page 28: ...66129915028...

Reviews: