3. Configuration
3.1 VXIbus
Address
Space
To simplify the integration of a ProDAQ 3120 module into a VXIbus system, it can be configured to
operate using either the VXIbus A24 or the VXIbus A32 address space for access to the function
cards in addition to the VXIbus configuration register space in the VXIbus A16 address space.
If jumper J1 on the motherboard is installed, the board will operate as a A16/A24 register based
VXIbus module. Without J1 installed, it will operate as a A16/A32 register based VXIbus module.
Figure 5 - Location of Jumper J1
J1