WINTERIZING YOUR TANK

The water in your storage tank system is at risk for freezing in the winter months, depending upon your climate 

and geography. Bushman recommends that you winterize your tank when there is the threat of freezing 

weather. The best solution is to drain your tank system. Be certain to drain any excess water from all hoses, 

and make sure any pump units are dry. Please note that our limited warranty programs do not cover any 

damage resulting from freezing conditions.

ABOVE GROUND TANK POSITIONING ON A STRUCTURE

1.  Prepare a structure that has hardwood decking with gaps no greater than 1 inch. The decking should be 

supported structurally by bearers strong enough to prevent sagging of the decking when the tank is full.

2.  Locate your water tank near an existing downspout or water source. If installing your tank with a BCK-0001 

first flush accessory kit (recommended) keep the tank within 6’ of the water source. The BCK-0001 has 

precut lengths of pipe that are 6’ long.

3.  The tank must be lifted into place by crane or similar equipment (equipment hire is at purchaser’s 

expense).

4.  The tank must then be tied down to the tank stand to prevent it from being blown away. Adding an inch or 

two of water in the tank will help keep it secure.

INSTALLATION

With the tank positioned on the pad or structure, install 3” SDR35 type 

pvc from the gutter or downspout into the pre-cut hole in the strainer 

lid on top of the tank. Alternatively downspout material could be used 

to convey the water into the tank through the same opening.

When installing the 3” pvc pipe or downspout be careful to keep the 

end of the pipe up above the screened basket under the lid. This gap 

will allow debris to flow out of the pipe and into the basket for removal 

later.

Summary of Contents for Tank

Page 1: ...1 866 920 8265 Monday through Friday 8 00am 5 00pm CST SECURING YOUR TANK When your tank arrives please put at least 1 of water into the tank or otherwise secure it from being blown away by unexpected winds Bushman takes no responsibility for tanks being damaged in this manner ABOVE GROUND TANK POSITIONING ON A PAD 1 Prepare a level area at least one foot larger than the diameter of your tank Inst...

Page 2: ...isting downspout or water source If installing your tank with a BCK 0001 first flush accessory kit recommended keep the tank within 6 of the water source The BCK 0001 has precut lengths of pipe that are 6 long 3 The tank must be lifted into place by crane or similar equipment equipment hire is at purchaser s expense 4 The tank must then be tied down to the tank stand to prevent it from being blown...

Page 3: ...at your own expense An overflow pipe could also be connected back into area or french drain systems located on the property Your tank will require a drain valve to be installed to release the water from the tank This item is purchased separately at your own expense Here are a couple suggestions 1 Add a ball valve recommended with a hose thread adapter 2 Add a spigot Both of these connections will ...

Page 4: ...ner basket cleaning Remove the 3 screws holding the lid and strainer down on the top of the tank Inspect the basket for debris clean as required and re install Overflow Extension Cleaning Pull the press fit screened overflow extension fitting off the overflow Inspect the screen for debris and clean as required Re install by pressing it back on the overflow ...

Reviews: